Background: Accurate measurement of a patient’s height and weight is an essential part of diagnosis and therapy, but there is some controversy as to how to calculate the height and weight of patients with disabilities. Objective: This study aims to use anthropometric measurements (arm span, length of leg, chest circumference, and waist circumference) to find a model (alternatives) that can allow the calculation of the height and the body weight of patients with disabilities. Additionally, a model for the prediction of weight and height measurements of patients with disabilities was established. Method: Four hander patients aged 20-80 years were enrolled in this study and divided into two groups, 210 (52.5%) male and 190 (47.5%) female. Result: A significant correlation was noted between body height and arm span, as well as between body height and length of leg in all study groups. The body weight and the ratio of arm span or leg length to the sum of chest and waist circumferences were found to have a negative significant correlation. Model equations were derived to estimate the height and body weight according to anthropometric measurements. Conclusion: Anthropometric measurements can be used to create a model for calculating the body height and body weight of patients with disabilities and which can be considered an alternative to measurements that can be made on otherwise healthy subjects.
The research seeks to identify the impact of fraud detection skills in the settlement of compensatory claims for the fire and accident insurance portfolio and the reflection of these skills in preventing and reducing the payment of undue compensation to some who seek profit and enrichment at the expense of the insurance contract. And compensatory claims in the portfolio of fire and accident insurance in the two research companies, which show the effect and positive return of the detection skills and settlement of the compensation on the amount of actual compensation against the claims inflated by some of the insured, The research sample consisted of (70) respondents from a community size (85) individuals between the director and assistan
... Show MoreCopper (Cu) Zinc (Zn) and Magnesium (Mg) in serum, RBC, urine and dialyzate fluids were
studied in 39 patients, who have been undergoing chronic haemodialysis treatment. They were
divided in to polyuric , oliguric and anuric depending on their urinary output. Elevated serum and
RBC Mg was observed before dialysis, while decreased serum and RBC level was noticed except
serum Mg of polyuric patients. Before dialysis elevated serum and RBC Zn were observed. While
after dialysis these parameters were increased. Normal RBC Cu value before dialysis was observed.
While low serum Cu was noticed. After dialysis serum Cu showed raised value, while RBC level
decreased in oliguric and increased in polyuric patients. Zn / Cu rati
Background: The incidence of maternal mortality in
placenta previa accrete is 7%,and its preoperative
diagnosis is of a great value.
Objective: to evaluate the efficacy of transabdominal
color Doppler ultrasound in diagnosing placenta
previa accreta and inccreta. Color Doppler imaging
criteria used in: includes diffuse parenchymal
placental lacunar flow, focal intra parenchymal
placental lacunar flow and bladder uterine serosa
interphase hyper-vascularity.
Design: Prospective study on patients from
January2007 to January 2008.
Patients and method: 48patients with one caesarean
section or more and with persistent anterior placenta
previa diagnosed by transabdominal ultrasound were
examined by c
The aim of this work was to develop and validate a rapid and low cost method for estimation of ibuprofen in pharmaceutical suspensions using Reverse-Phase High Performance Liquid Chromatography. The proposed method was conducted and validated according to International Conference on Harmonization (ICH) requirements. The chromatographic parameters were as follows: column of octyldecylsilyl C18 with dimensions (150 × 4.6) mm, mobile phase composed of acetonitrile with phosphoric acid with a ratio of 50 to 50 each using isocratic mode, flow rate of 1.5 mL/min and injection volume of 5 μL. The detection was carried out using UV detector at 220 nm. The method was validated and showed short retention time for ibuprofen peak at 7.651 min, wit
... Show MoreAutoría: Nuha Mohsin Dhahi. Localización: Revista iberoamericana de psicología del ejercicio y el deporte. Nº. 5, 2022. Artículo de Revista en Dialnet.
The differential protection of power transformers appears to be more difficult than any type of protection for any other part or element in a power system. Such difficulties arise from the existence of the magnetizing inrush phenomenon. Therefore, it is necessary to recognize between inrush current and the current arise from internal faults. In this paper, two approaches based on wavelet packet transform (WPT) and S-transform (ST) are applied to recognize different types of currents following in the transformer. In WPT approach, the selection of optimal mother wavelet and the optimal number of resolution is carried out using minimum description length (MDL) criteria before taking the decision for the extraction features from the WPT tree
... Show MoreAbstract
This research aims to study and improve the passivating specifications of rubber resistant to vibration. In this paper, seven different rubber recipes were prepared based on mixtures of natural rubber(NR) as an essential part in addition to the synthetic rubber (IIR, BRcis, SBR, CR)with different rates. Mechanical tests such as tensile strength, hardness, friction, resistance to compression, fatigue and creep testing in addition to the rheological test were performed. Furthermore, scanning electron microscopy (SEM)test was used to examine the structure morphology of rubber. After studying and analyzing the results, we found that, recipe containing (BRcis) of 40% from th
... Show MoreThis paper presents L1-adaptive controller for controlling uncertain parameters and time-varying unknown parameters to control the position of a DC servomotor. For the purpose of comparison, the effectiveness of L1-adaptive controller for position control of studied servomotor has been examined and compared with another adaptive controller; Model Reference Adaptive Controller (MRAC). Robustness of both L1-adaptive controller and model reference adaptive controller to different input reference signals and different structures of uncertainty were studied. Three different types of input signals are taken into account; ramp, step and sinusoidal. The L1-adaptive controller ensured uniformly bounded
... Show More