Preferred Language
Articles
/
QBdRZo8BVTCNdQwCbnas
Immunological and molecular detection of herpes simplex virus type 1 and 2 in patients clinically diagnosed with parkinson’s disease and multiple sclerosis
...Show More Authors

To determine the relationship between herpes simplex virus 1, 2 and neurological disorders, sixty samples from patients with neurological diseases were collected (40 patients with Multiple sclerosis and 20 patients with Parkinson’s disease) all of whom attended both the Neurological science Hospital as well as the Neuropathology consultation Department in Baghdad Hospital In Iraq. The samples were collected in the time frame between November 2017 and April 2018. The ages of the patients that were investigated were between (17-76) years and compared to a control group consisting of 25 samples collected from apparently healthy individuals. All the studied groups were subjected to the measurement of anti-HSV 1, 2 IgG antibodies by the means of an Enzyme Linked Immunosorbent Assay (ELISA) technique followed by the genetic detection of the virus using a quantitative polymerase chain reaction (qPCR). The results of the current study revealed that there was a none-significant difference (p>0.05)in the concentration of HSV- 1, 2IgG antibody in the sera of the patients with multiple sclerosis and Parkinson’s disease compared to the healthy control group. The study also showed that 17.39% of the Multiple sclerosis sample’s tested using qPCR resulted in the positive detection of HSV-1 DNA and while only 9.3% of the same samples tested positive for the presence of HSV-2 DNA.As for the samples from the Parkinson’s patients and the control samples both tested negative for any amplification of viral DNA for both HSV one and two. Statistical analysis proved these results to be statistically in significant

Publication Date
Thu Jun 01 2023
Journal Name
International Journal Of Artificial Intelligence (ij-ai)
Evaluation of massive multiple-input multiple-output communication performance under a proposed improved minimum mean squared error precoding
...Show More Authors

<span lang="EN-US">The fundamental of a downlink massive multiple-input multiple-output (MIMO) energy- issue efficiency strategy is known as minimum mean squared error (MMSE) implementation degrades the performance of a downlink massive MIMO energy-efficiency scheme, so some improvements are adding for this precoding scheme to improve its workthat is called our proposal solution as a proposed improved MMSE precoder (PIMP). The energy efficiency (EE) study has also taken into mind drastically lowering radiated power while maintaining high throughput and minimizing interference issues. We further find the tradeoff between spectral efficiency (SE) and EE although they coincide at the beginning but later their interests become con

... Show More
Scopus Crossref
Publication Date
Thu Jun 01 2023
Journal Name
Iaes International Journal Of Artificial Intelligence (ij-ai)
Evaluation of massive multiple-input multiple-output communication performance under a proposed improved minimum mean squared error precoding
...Show More Authors

<span lang="EN-US">The fundamental of a downlink massive multiple-input multiple-output (MIMO) energy- issue efficiency strategy is known as minimum mean squared error (MMSE) implementation degrades the performance of a downlink massive MIMO energy-efficiency scheme, so some improvements are adding for this precoding scheme to improve its workthat is called our proposal solution as a proposed improved MMSE precoder (PIMP). The energy efficiency (EE) study has also taken into mind drastically lowering radiated power while maintaining high throughput and minimizing interference issues. We further find the tradeoff between spectral efficiency (SE) and EE although they coincide at the beginning but later their interests become con

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Sat Jan 01 2022
Journal Name
P J M H S
Synthesis and Spectro Scopic Study of Some Metal Transition Amino Organic Compounds with N-(2-OXO-1,2-Dihydropyrimidin-4- Ylcarbamothioyl) Acetamide (DPA)
...Show More Authors

A New ligand, N-(2-oxo-1,2- Dihydropyrimidin-4- ylcarbamothioyl) Acetamide (DPA) was prepared by reaction of iso thiosyanate derivative with Cytosine. The ligand has been characterized through elemental analysis, H1 NMR, C13NMR, FT-IR, and UV Visible spectra, such ligand’s transition metal complexes have been characterized through conductivity measurement, FT-IR, UV Visible spectra and magnetic susceptibility, all the complexes of this ligand are solid crystal and molar ratio (2:1) (ligand: metal). The form of molecular for these complexes octa hedral. The general formula [M(DPA)2Cl2], where M+2 = (Mn, Co, Ni, Cu, Zn, Cd, Hg).

Publication Date
Tue Jun 17 2025
Journal Name
Baghdad Science Journal
Synthesis and Biological Study of Schiff–Mannich Base Derived from 2-Mercaptobenzimidazole as Chelated Tridentate Ligand with Some Transition Metal Ions Complexes
...Show More Authors

To prepare a new ligand, many compounds were used to synthesize Schiff-Mannich base, such as isatin, Para chloro Aniline, 2-mercaptobenzimidazole and indole. The resulting compound 1-((2-((1H-indol-1-ylthio)-1H-benzo[d]imidazol1-yl)methyl)-3-(4-chlorophenylimino)indolin-2-one (L). (L) was used to create a series of metal ion complexes with Co (II), Ni (II), Cu (II), Pd (II), Pt (IV), and Au (III). C.H.N.S., FTIR, mass spectra UV-ViS, 1H-NMR, 13CNMR, magnetic moment, and molar conductivity were used to characterize all of these compounds. Except for the palladium(II) and gold(III) complexes, all of the produced complexes had an octahedral geometry, according to the data. The antibacterial activity of the produced compounds was tested by usin

... Show More
View Publication
Scopus (2)
Scopus Crossref
Publication Date
Thu Feb 18 2021
Journal Name
Journal Of Optical Communications
Theoretical investigation of multiple input–multiple output (MIMO) technique for line of sight (LoS) underwater wireless optical communications system
...Show More Authors
Abstract<p>In this paper, a theoretical investigation was suggested to study underwater wireless optical communication (UWOC) system based on multiple input–multiple output (MIMO) technique. The modulation schemes such as RZ-OOK, NRZ-OOK, 32-PPM and 4-QAM applied under different coastal water types. MIMO technique enabled the system to transmit data rate with longer distance link. The performance of the proposed system examined by BER and data rate as a metrics. Several impairments such as the types of water by the attenuation of coastal water and the distance link were taken into account for the transmission of the optical signal to appreciate the reliability of the MIMO technique. The theore</p> ... Show More
View Publication
Scopus (19)
Crossref (20)
Scopus Crossref
Publication Date
Wed May 01 2024
Journal Name
Baghdad Science Journal
Early Prediction of Nephropathy in Iraqi Patient with Diabetes Type II by Evaluating Some Relevant Biochemical Factors
...Show More Authors

داء السكري من النوع 2 (T2DM) هو مرض معقد يصيب العديد من الأعضاء إلى جانب البنكرياس مثل الكلى والكبد والدماغ والعين. بسبب ارتفاع السكر في الدم لفترات طويلة وعدم السيطرة على مرض السكري مع وجود عوامل خطر أخرى ، يمكن أن تحدث مضاعفات مرض السكري. تشمل مضاعفات مرض السكري مضاعفات الأوعية الدموية الدقيقة والأوعية الدموية الكبيرة التي تستهدف الكلى. تهدف الدراسة الحالية إلى التحقق من مستوى الانجوتينسن المحول للانزيم  A

... Show More
View Publication
Scopus (7)
Crossref (4)
Scopus Crossref
Publication Date
Sun Jun 06 2010
Journal Name
Baghdad Science Journal
New Method for the Determination of DL-Histidine by FIA and Chemiluminometric Detection
...Show More Authors

This paper present a simple and sensitive method for the determination of DL-Histidine using FIA-Chemiluminometric measurement resulted from oxidation of luminol molecule by hydrogen peroxide in alkaline medium in the presence of DL-Histidine. Using 70?l. sample linear plot with a coefficient of determination 95.79% for (5-60) mmol.L-1 while for a quadratic relation C.O.D = 96.44% for (5-80) mmol.L-1 and found that guadratic plot in more representative. Limit of detection was 31.93 ?g DL-Histidine (S/N = 3), repeatability of measurement was less that 5% (n=6). Positive and negative ion interferances was removed by using minicolume containing ion exchange resin located after injection valve position.

View Publication Preview PDF
Crossref
Publication Date
Mon Jul 01 2024
Journal Name
Journal Of Engineering
Efficient Intrusion Detection Through the Fusion of AI Algorithms and Feature Selection Methods
...Show More Authors

With the proliferation of both Internet access and data traffic, recent breaches have brought into sharp focus the need for Network Intrusion Detection Systems (NIDS) to protect networks from more complex cyberattacks. To differentiate between normal network processes and possible attacks, Intrusion Detection Systems (IDS) often employ pattern recognition and data mining techniques. Network and host system intrusions, assaults, and policy violations can be automatically detected and classified by an Intrusion Detection System (IDS). Using Python Scikit-Learn the results of this study show that Machine Learning (ML) techniques like Decision Tree (DT), Naïve Bayes (NB), and K-Nearest Neighbor (KNN) can enhance the effectiveness of an Intrusi

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Dec 30 2022
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Artificial Intelligent Models for Detection and Prediction of Lost Circulation Events: A Review
...Show More Authors

Lost circulation or losses in drilling fluid is one of the most important problems in the oil and gas industry, and it appeared at the beginning of this industry, which caused many problems during the drilling process, which may lead to closing the well and stopping the drilling process. The drilling muds are relatively expensive, especially the muds that contain oil-based mud or that contain special additives, so it is not economically beneficial to waste and lose these muds. The treatment of drilling fluid losses is also somewhat expensive as a result of the wasted time that it caused, as well as the high cost of materials used in the treatment such as heavy materials, cement, and others. The best way to deal with drilling fluid losses

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Fri Feb 08 2019
Journal Name
Journal Of The College Of Education For Women
COMPARATIVE STUDY FOR EDGE DETECTION OF NOISY IMAGE USING SOBEL AND LAPLACE OPERATORS
...Show More Authors

Many approaches of different complexity already exist to edge detection in
color images. Nevertheless, the question remains of how different are the results
when employing computational costly techniques instead of simple ones. This
paper presents a comparative study on two approaches to color edge detection to
reduce noise in image. The approaches are based on the Sobel operator and the
Laplace operator. Furthermore, an efficient algorithm for implementing the two
operators is presented. The operators have been applied to real images. The results
are presented in this paper. It is shown that the quality of the results increases by
using second derivative operator (Laplace operator). And noise reduced in a good

... Show More
View Publication Preview PDF