This paper presents studying the performance of three types of polyethersulfone (PES) membrane for the simultaneous removal of Co2+ ions, Cd2+ ions, and Pb2+ ions from binary and ternary aqueous solutions. Co2+ ions, Cd2+ ions, and Pb2+ ions with two different initial concentrations (e.g., 10 and 50 ppm) were selected as examples of heavy metals that contaminate the groundwater as a result of geological and human activities. This study investigated the effect of types of PES membrane and metal ions concentration on the separation process. For the binary aqueous solutions, the permeation flux of the PES2 membranes was higher for the separation process of solutions containing 50 ppm of Cd2+ ions and 10 ppm of Co2+ ions (24.7 L/m2·h) and Pb2+ ions (23.7 L/m2·h). All the metals in the binary solutions had high rejection when their initial concentration was lower than the initial concentration of the other metal present in the same solution. Using PES2, the maximum rejection of Cd2+ ions was 61.3% when the initial concentrations were 50 ppm Pb2+ ions: 10 ppm Cd2+ ions and 55.4% for Pb2+ ions when the initial concentrations were 10 ppm Pb2+ ions: 50 ppm Cd2+ ions. For the ternary aqueous solutions, the rejection and the permeation flux of the PES membranes increased with decreasing the heavy metal initial concentration. Using PES2, the maximum permeation flux was 21.6 L/m2·h when the initial concentration of the metals was 10 ppm; and the maximum rejection of the metals obtained at initial concentration of 10 ppm was 50.5% for Co2+ ions, 48.3% for Cd2+ ions, and 40% for Pb2+ ions. The results of the filtration process using PES2 of simulated contaminated-groundwater indicated the efficient treatment of groundwater containing Co2+, Cd2+, and Pb2+ ions.
In today’s competitive environment, organizational efficiency and sustained growth are crucial for survival. The performance of an organization is intricately connected to strategic planning, prompting firms to gather and leverage competitive information for a competitive advantage. Senior managers, recognizing this, initiate actions accordingly. This study aims to investigate the relationship between foresight, vision, strategic partnerships, motivation, system thinking, and organizational performance. Data, gathered through a self-administered questionnaire from various textile units, were analysed using structural equation modelling (SEM). The findings indicate that sub-constructs of strategic intelligence positively impact organizatio
... Show MoreThe determination of river pollution impact on the performance of water treatment plants is achieved by two main objectives. The first is to study raw and treated water qualities and comparing them with standards and the second is to evaluate the treatment plants efficiency. The analyzed data were those water quality parameters in relation to physical, chemical and bacteriological characteristics for river water and produced water by seven water treatment plants located on Tigris River passing through Baghdad City.
The results of this study indicated that all raw water characteristic are within the surface water standards established by Iraqi and USA criteria except Bacterial Counts.
Tigris River water is of good quality to be trea
The current research illustrates experimentally the effect of series and parallel connection (Z-I Configurations) of flat plate water solar collectors array on the thermal performance of closed loop solar heating system. The study includes the effect of changing the water flow rate on the thermal efficiency. The results show that, the collector's efficiency in series connection is higher than the parallel connection within flow rate level less than (100) ℓ/hr. Moreover, the collector efficiency in parallel connection of (I-Configurations) is more than the (Z- Configurations) with increasing the water flow rate .The maximum daily efficiency for parallel (I-Configurations) and (Z- Configurations) are (55%) and (51%) at w
... Show MoreMost reinforced concrete (RC) structures are constructed with square/rectangular columns. The cross-section size of these types of columns is much larger than the thickness of their partitions. Therefore, parts of these columns are protruded out of the partitions. The emergence of columns edges out of the walls has some disadvantages. This limitation is difficult to be overcome with square or rectangular columns. To solve this problem, new types of RC columns called specially shaped reinforced concrete (SSRC) columns have been used as hidden columns. Besides, the use of SSRC columns provides many structural and architectural advantages as compared with rectangular columns. Therefore, this study was conducted to explain the structura
... Show MoreRecently, environmental noise has arisen from various sources, such as those from exhaust mufflers of combustion engines found in cars, trucks, or power generators, which produce significant noise during their operation. Controlling the radiated noise from these mufflers is a major factor in improving acoustic comfort and minimizing the impact on the surrounding communities. Numerous research has been presented for this reason by modification of the internal structure of the exhaust muffler. The main objective of this work is to reduce the noise level emitted from exhaust mufflers. This can be achieved by adjusting structure parameters to attenuate the surrounding environment's radiated noise. Analysis of pressure-wave propagation h
... Show MoreSloped solar chimney system is a solar chimney power plant with a sloped collector. Practically, the sloped collector can function as a chimney, then the chimney height can be reduced and the construction cost would be reduced.The continuity, Naver-stockes, energy and radiation transfer equations have been solved and carried out by Fluent software. The governing equations are solved for incompressible, 3-D, steady, turbulent standard model with Boussiuesq approximation to develop for the sloped solar chimney system in this study and evaluate the performance of solar chimney power plant in Baghdad city of Iraq numerically by Fluent (14) software with orking conditions such as solar radiation intensity (30
... Show MoreThis study aims to show the level of organizational fairness at Hawija Technical Institute ,from the point view of the faculty ,and the degree of their performance, and the nature of the relationship between organizational fairness and their performance.
The researchers accomplish and develop a questionnaire on Likert a three - dimensional scale to de applied on a samp
... Show MoreHigh-rise structures are a significant indication in contemporary urban improvement, mainly in areas characterized by accelerated urban growth and dense population. This type of building should be designed to withstand severe load conditions. Therefore, using composite structural elements in such structures is required for stronger and durable elements. This paper introduces a finite element analysis model for Concrete Filled Stainless Steel Tubular Columns (CFSST) of (100x100) mm cross-section and (1250) mm length to inspect the impact of concrete compressive strength on the response of (CFSST). The generated model was first evaluated through a comprehensive comparison with experimental research. Then, after the model was used to s
... Show More