Field experiments were carried out for the autumn season 2022- 2021 in the field of College of Agricultural Engineering Sciences - University of Baghdad - Jadiriyah Complex –Station A- to study a combination of organic fertilizer (Vermicompost) and cow manure as well as a control treatment (soil only) intertwined with Spraying with silicon, calcium and distilled water (control) in the growth and production of three cultivars of beet (Cylindra, Dark Red, Red) within the design of Completely Randomized Block Design at three replications, The number of treatments was 9 for each replicate. The means were compared according to the least significant difference (L.S.D) at a probability level of 5 %, the results were as follows:-The interaction treatment of the Vermicompost with calcium spraying in the number of leaves, the concentration of chlorophyll, the percentage of nitrogen and phosphorous), was significantly superior to the combination of Vermicompost with spraying silicon significantly (in the percentage of potassium, the concentration of silicon, the root yield, the leaf yield, the percentage of dry matter, phenols and sugars), at a rate of (387.67,3%.28 mg kg−1, 35.88 ton h−1, 50 ton h−1, 8.78%, 014% and 889%) respectively. As for the percentage of calcium, it was characterized by the combination treatment of cow manure with calcium spray, and the combination of cow manure with silicon spray was superior in T.S.S. and the percentage of fiber at 3.17 and 11.66% respectively for the Red variety.As for the variety Red Dark it was significantly superior to the mixture of the medium vericompost with silicon spray in the number of leaves, the concentration of chlorophyll and the percentage of nitrogen, the concentration of silicon, Root yield and leaf yield Percentage of dry matter T.S.S, phenols and sugars at (10 leaf plant−1, 82.2 mg 100 fresh wet−1, 3.53%, 313.00 mg kg−1, 36.35 ton h−1, 40.92 ton h−1, 6.86%, 11.03%, 0.16% and 845%) respectively, while the percentage of phosphorous and potassium, it was characterized by the combination of cow manure with silicon spray, and the combination of vermicompost with calcium spray was superior to the percentage of calcium and the percentage of fiber by giving it 2.19% and 2.50% respectively. As for the variety Cylindra it was significantly superior to the combination of the Vericompost with silicon spray in the number of leaves, concentration of chlorophyll, percentage of nitrogen, phosphorous, silicon, root yield, leaf yield, Percentage of dry matter, T.S.S, Whereas, the treatment with cow manure overlapping with silicon was superior in the percentage of potassium, phenols and sugars, as it gave 4.11% 0.13 and 665% respectively, The treatment of the Vermicompost with calcium spray was characterized in the percentage of calcium as it gave 1.65%.
This paper features the modeling and design of a pole placement and output Feedback control technique for the Active Vibration Control (AVC) of a smart flexible cantilever beam for a Single Input Single Output (SISO) case. Measurements and actuation actions done by using patches of piezoelectric layer, it is bonded to the master structure as sensor/actuator at a certain position of the cantilever beam.
The smart structure is modeled based on the concept of piezoelectric theory, Bernoulli -Euler beam theory, using Finite Element Method (FEM) and the state space techniques. The number of modes is reduced using the controllability and observability grammians retaining the first three
dominant vibratory modes, and for the reduced syste
Many studies and researchers have reported significant evidence that some physical properties of water can be changed as it passes through a magnetic field that can improve water use. This can have a promising potential for applications, especially in the fields of irrigation and drainage. In this research, magnetized water was used to leach salt-affected sandy loam soil. A test rig was designed and constructed to investigate the effects of magnetized water on leaching soil. The rig consists of a magnetization device that can provide variable intensity. Water was supplied from a constant head reservoir to the magnetization device then to the soils that were placed in plastic columns. Five different magnetic intensi
... Show MoreDue to the deliberate disposal of industrial waste, a great amount of petroleum hydrocarbons pollute the soil and aquatic environments. Bioremediation that depends on the microorganisms in the removal of pollutants is more efficient and cost-effective technology. In this study, five rhizobacteria were isolated from Phragmites australis roots and exposed to real wastewater from Al-Daura refinery with 70 mg/L total petroleum hydrocarbons (TPH) concentration. The five selected rhizobacteria were examined in a biodegradation test for seven days to remove TPH. The results showed that 80% TPH degradation as the maximum value by Sphingomonas Paucimobilis as identified with Vitek® 2 Compact (France).
The problem of water scarcity is becoming common in many parts of the world, to overcome part of this problem proper management of water and an efficient irrigation system are needed. Irrigation with a buried vertical ceramic pipe is known as a very effective in the management of irrigation water. The two- dimensional transient flow of water from a buried vertical ceramic pipe through homogenous porous media is simulated numerically using the HYDRUS/2D software. Different values of pipe lengths and hydraulic conductivity were selected. In addition, different values of initial volumetric soil water content were assumed in this simulation as initial conditions. Different value
... Show MoreRoughness length is one of the key variables in micrometeorological studies and environmental studies in regards to describing development of cities and urban environments. By utilizing the three dimensions ultrasonic anemometer installed at Mustansiriyah university, we determined the rate of the height of the rough elements (trees, buildings and bridges) to the surrounding area of the university for a radius of 1 km. After this, we calculated the zero-plane displacement length of eight sections and calculated the length of surface roughness. The results proved that the ranges of the variables above are ZH (9.2-13.8) m, Zd (4.3-8.1) m and Zo (0.24-0.48) m.
The concrete industry consumes millions of tons of aggregate comprising of natural sands and gravels, each year. In recent years there has been an increasing trend towards using recycled aggregate to save natural resources and to produce lightweight concrete. This study investigates the possibility of using waste plastic as one of the components of lead-acid batteries to replace the fine aggregate by 50 and 70% by volume of concrete masonry units. Compared to the reference concrete mix, results demonstrated that a reduction of approximately 32.5% to 39.6% in the density for replacement of 50% to 70% respectively. At 28 days curing age, the compressive strength was decreased while the water absorption increased by increas
... Show MoreTwo samples of (Ag NPs-zeolite) nanocomposite thin films have been prepared by easy hydrothermal method for 4 hours and 8 hours inside the hydrothermal autoclave at temperatures of 100°C. The two samples were used in a photoelectrochemical cell as a photocatalyst inside a cell consisting of three electrodes: the working electrode photoanode (AgNPs-zeolite), platinum as a cathode electrode, and Ag/AgCl as a reference electrode, to study the performance of AgNPs-zeolite under dark current and 473 nm laser light for water splitting. The results show the high performance of an eight-hour sample with high crystallinity compared with a four-hour sample as a reliable photocatalyst to generate hydrogen for renewable energies.
Enhancement of the performance for hybrid solar air conditioning system was presented in this paper. The refrigerant temperature leaving the condenser was controlled using three-way valve, this valve was installed after the compressor to regulate refrigerant flow rate towards the solar system. A control system using data logger, sensors and computer was proposed to set the opening valve ratio. The function of control program using LabVIEW software is to obtain a minimum refrigerant temperature from the condenser outlet to enhance the overall COP of the unit by increasing the degree of subcooled refrigerant. A variable load electrical heater with coiled pipe was used instead of the solar collector and the storage tank to simulate the sola
... Show MoreIraq, home of the Tigris and Euphrates rivers, has survived an extreme deficiency of surface water assets over the years. The gap is due to the decline of the Iraqi water share every year, as well as a high demand for water use from different sectors, particularly agriculture.
Dam development has long given significant economic benefits to Iraq in circulating low‐priced electricity and supporting low‐income farmers by supplying them with a free irrigation system (Zakaria et al, 2012). This encouraged domestic consumption and investment.
Despite the fact that numerous advantages are expected from dam construction, it should be painstakingly assessed, utilizing cost