Bioavailability is the objective for an optimum formulation. The target of the analysis is to maximize both the fluidity and disintegration profile of class II weakly compounds that are water-soluble. Anti-dyslipidemia drug rosuvastatin calcium (RC) (bioavailability 20%) through formulating as nanofibers (NFs) using electrospinning (ES) technology. Twenty formulas were prepared, and different polymers and polymer combinations with various concentrations were used such as polyethylene oxide (PEO) polyvinyl pyrrolidine (PVPK-30), and hydroxypropyl methylcellulose (HPMC). Three distinct groups of maximum parameters, including polymeric solution, electrospinning method, and ambient parameter, are capable of influencing the creation along with the shape of those ultimate NFs. The prepared formulas of rosuvastatin calcium nanofibers (RC-NFs) were evaluated for nanofibers diameter, dissolution profiles, free standing microscopy with electrons and fourier transformation infrared (FTIR)spectroscopy are also available. As a consequence, the velocity of dissolution increases as the particle’s surrounding area increases because of the its small size decrease to the nano level. The optimum ES parameters of polymeric solution (polymer type, concentration, combination, and effect of solvent type), ES process (injection flow rate, voltage, needle gauge, collector round per minute, needle to collector distance and collector type) and ambient parameter are tested and determined. Results show that four selected formulas of NFs are (F12, F14, F15 and F19) with an average diameter of (95, 120, 100 and 80 nm) respectively. The best ultrafine, smooth and beadless NFs is (F19) determined the fact that the narrower the circumference of the RC-NFs, the quicker its breakdown and the shorter the period of this medicinal component’s liberation.
Background: Optimal root canal retreatment was required safe and efficient removal of filling material from root canal. The aim of this in vitro study was to compare the efficacy of reciprocating and continuous motion of four retreatment systems in removal of root canal filling material. Materials and Methods: Forty distal roots of the mandibular first molars teeth were used in this study, these roots were embedded in cold clear acrylic,roots were instrumented using crown down technique and rotary ProTaper systemize Sx to size F2 ,instrumentation were done with copiousirrigation of 2.5% sodium hypochlorite and 17% buffered solution of EDTA was used as final irrigant followed by distilledwater, roots were obturated with AH26 sealer and Prota
... Show MoreBackground: Optimal root canal retreatment was required safe and efficient removal of filling material from root canal. The aim of this in vitro study was to compare the efficacy of reciprocating and continuous motion of four retreatment systems in removal of root canal filling material. Materials and Methods: Forty distal roots of the mandibular first molars teeth were used in this study, these roots were embedded in cold clear acrylic,roots were instrumented using crown down technique and rotary ProTaper systemize Sx to size F2 ,instrumentation were done with copiousirrigation of 2.5% sodium hypochlorite and 17% buffered solution of EDTA was used as final irrigant followed by distilledwater, roots were obturated with AH26 sealer and Prota
... Show MoreBackground: A successful endodontic treatment is aimed at the sterilization of the entire pulp space. The use of extracts from Rhamnus prinoides as a novel irrigating material for root canal has not been studied . Hence, the antimicrobial efficacy of the alcoholic extract of Rhamnus prinoides as an irrigation material against E. faecalis was evaluated in comparison with the 2.5% sodium hypochlorite (NaOCL) solution used for root canals of permanent teeth. Methods: A total of 30 single-rooted human permanent teeth were thoroughly cleaned, shaped, and disinfected. Then, each tooth was subjected to a two-week infection with Enterococcus faecalis at 37 °C . Afterward, the samples were divided into three groups (10 teeth per group): 0.9
... Show MoreBackground: Pleural effusion is a common clinical
problem.
Objective: The aim of the study was to evaluate the
diagnostic utility of Carcino embryonic antigen
(CEA), CA 15- 3, and alpha-feto protein ( AFP ) as
a tumor markers in serum and pleural effusion and
evaluate the value of combining them as a diagnostic
tools that are complementary to cytology in the
diagnosis of malignancies .
Methods: Forty patients (18 malignant and 22 benign
pleural effusion) were included in this study .The
serum and effusion levels of CEA, CA 15 – 3 and
AFP were measured using immunoradiometric assay
Results: from the 40 effusions studied 26 were
exudates and 14 were transudates. The level of
pleural effusions
To ensure that a software/hardware product is of sufficient quality and functionality, it is essential to conduct thorough testing and evaluations of the numerous individual software components that make up the application. Many different approaches exist for testing software, including combinatorial testing and covering arrays. Because of the difficulty of dealing with difficulties like a two-way combinatorial explosion, this brings up yet another problem: time. Using client-server architectures, this research introduces a parallel implementation of the TWGH algorithm. Many studies have been conducted to demonstrate the efficiency of this technique. The findings of this experiment were used to determine the increase in speed and co
... Show MoreTraditionally, path selection within routing is formulated as a shortest path optimization problem. The objective function for optimization could be any one variety of parameters such as number of hops, delay, cost...etc. The problem of least cost delay constraint routing is studied in this paper since delay constraint is very common requirement of many multimedia applications and cost minimization captures the need to
distribute the network. So an iterative algorithm is proposed in this paper to solve this problem. It is appeared from the results of applying this algorithm that it gave the optimal path (optimal solution) from among multiple feasible paths (feasible solutions).
ABSTRACT Background: One of the challenges to use chlorhexidine is its effect on the amount of microleakage after restoration; however, use of the materials with antibacterial properties after tooth preparation and before restoration has been widespread. The objective of this, in-vitro, study was to evaluate the influence of consepsis (chlorhexidine gloconate disinfectant) application on microleakage in class II cavities restored with light cured composite using universal adhesive system; etch and rinse technique –self etch technique. Materials and Methods: Forty class II cavities were prepared on mesial and distal surfaces of 20 non-carious mandibular third molars. The cavities were divided into four groups; (n =10 for each group).
... Show MoreObjectives. This study was carried out to quantitatively evaluate and compare the sealing ability of Endoflas by using differentobturation techniques. Materials and Methods. After 42 extracted primary maxillary incisors and canines were decoronated, theircanals were instrumented with K files of size ranging from #15 to #50. In accordance with the obturation technique, the sampleswere divided into three experimental groups, namely, group I: endodontic pressure syringe, group II: modified disposable syringe,and group III: reamer technique, and two control groups. Dye extraction method was used for leakage evaluation. Data wereanalyzed using one-way ANOVA and Dunnett’s T3 post hoc tests. The level of significance was set at p<0:05. Results.
... Show MoreLaser skin wound soldering offers many distinct advantages over conventional closure and laser welding techniques. Objective : to compare the histological effects of human skin wound soldering using 50 % human albumin solder and compound charcoal photosensitiser with 980 nm diode laser acting in various modes of action and parameters. Study Design/Materials and Methods: In this in vitro experimental study , Multiple 3-4 cm long full thickness incisions in a specimen of human skin were soldered using a 4 mm spot diameter beam of 980 nm diode laser(at different laser parameters and modes of action) with 50 % human albumin solder mixed with the compound charcoal at 5 % W/V concentration .After obtaining a successful wound soldering , the wo
... Show More