Background: Color stability of glass ionomers (GIs) could be affected by many factors such as pH and consumption of liquid medications like antibiotics. Most common antibiotics used during childhood are amoxicillin suspension (AM.S) and azithromycin suspension (AZ.S) which have acidic and basic pH respectively. Aim: to evaluate and compare the effect of AM.S and AZ.S on color stability of nano resin-modified GI. Methods: Thirty disc of nano resin-modified glass ionomer (2mm height x 4mm diameter) were divided into three groups (n=10 for each) and independently exposed to AM.S, AZ.S, and artificial saliva (A.S.). Color stability was evaluated in triplicate by VITA Easyshade® before and after three immersion protocols, repeated over a three-week duration with two-days intervals. In each protocol, samples were exposed for two minutes, three times daily for AM.S, once daily for AZ.S, and A.S. full day. GI discs rinsed off after each immersion and kept in artificial saliva until next immersion period. Results: One way ANOVA test and Post-hoc analysis of the changes in color space compartments of nano-resin modified GI samples demonstrated just a significant change (p˂0.05) in yellow-blue axis (Δb*) value after immersion in AM.S in comparison with A.S. Total Color change values (ΔE) of nano resin-modified glass ionomer samples also illustrated a significant effect (p˂0.05) between AM.S and A.S. only. The highest (ΔE) value was recorded for samples immersed in AM.S (ΔE =12.5) followed by AZ.S (ΔE=6.5) while the lowest was recorded for A.S. (ΔE=1.1). Conclusion: AM.S (the acidic medication) exhibited a higher staining effect to nano-resin modified GI samples when compared with AZ.S (the basic medication). Several factors such as low pH, more exposure time and coloring material of the immersion media added critical roles in coloring instability.
This study concerns the removal of a trihydrate antibiotic (Amoxicillin) from synthetically contaminated water by adsorption on modified bentonite. The bentonite was modified using hexadecyl trimethyl ammonium bromide (HTAB), which turned it from a hydrophilic to a hydrophobic material. The effects of different parameters were studied in batch experiments. These parameters were contact time, solution pH, agitation speed, initial concentration (C0) of the contaminant, and adsorbent dosage. Maximum removal of amoxicillin (93 %) was achieved at contact time = 240 min, pH = 10, agitation speed = 200 rpm, initial concentration = 30 ppm, and adsorbent dosage = 3 g bentonite per 1L of pollutant solution. The characterization of the adsorbent, modi
... Show MoreA new modified differential evolution algorithm DE-BEA, is proposed to improve the reliability of the standard DE/current-to-rand/1/bin by implementing a new mutation scheme inspired by the bacterial evolutionary algorithm (BEA). The crossover and the selection schemes of the DE method are also modified to fit the new DE-BEA mechanism. The new scheme diversifies the population by applying to all the individuals a segment based scheme that generates multiple copies (clones) from each individual one-by-one and applies the BEA segment-wise mechanism. These new steps are embedded in the DE/current-to-rand/bin scheme. The performance of the new algorithm has been compared with several DE variants over eighteen benchmark functions including sever
... Show MoreThe varied thermal conductivity (insulation) of silica aerogel with heating for different pH has been investigated, it has been depended on ambient pressure drying method in the preparing silica aerogel samples, also six different pH of samples (1, 2, 3, 7, 8 and 9) were treated under five degree of heating with (50,100,150,200 and 250) ᴼC. This technique is important to test the carry-outs hydrophobic silica to temperature without high-quality material changes in the basic characteristics. The hot-wire technique is used in this work to examine the thermal conductivity, Fourier Transform Infrared Spectroscopy (FTIR) depended to characterize the bonds and their artificial by heating. Resu
... Show MoreBackground: Determination of local bone mineral density (BMD) immediately after implant insertion play an important role in implant success rate, may offer comprehensive description of the bone, and give enough information to the surgeon prior to implant insertion and at follow up status. The aim of the present study is to evaluate the changes of local bone density in the dental implant recipient sites by using computerized tomography. Material and method: The sample consisted of (20) dental implants recipient sites, bone density assessment was done twice, immediately after implants insertion and after six months. Results: The mean HU of the bone around the implant insertion site, immediately after implant placement was 552.28 HU, and inc
... Show MoreThe aim of this research work is to evaluate the use of 980 nm diode laser in clotting the blood
in the bone socket after tooth extraction. The objective is to prevent possible clot dislodgement which is
a defect that may lead to possible infection. A number of rabbits were irradiated using 980nm CW mode
diode laser, 0.86W power output for 9s and 15s exposure time. The irradiated groups were studied
histopathologically in comparison with a control group. Results showed that laser photothermal
coagulation was of benefit in minimizing the possibility of the incidence of postoperative complications.
The formation of the clot reduces the possibility of bleeding and infection.
The rapid spread of the COVID-19 coronavirus in 2019 infected many people, primarily affecting the respiratory system. Both COVID-19 and type 2 diabetes have been associated with numerous risks that have become life-threatening. The study studied the link between galectin levels and some clinical characteristics in Iraqis with type 2 diabetes and COVID-19 against those without diabetes. The study included 120 patients and healthy men. Three groups were formed for this study depending on the initial mutant cell line: 80 samples of individuals with type 2 diabetes, aged 40–60 years, with and without COVID-19, were included in each of the first and second groups. The control group consisted of 40 research participants who were matched for ag
... Show MoreThe present study aimed to investigate the acetamiprid effects on biochemical aspects in albino mice. Thirty albino mice at the age of 6-8 weeks and average weight 25±5 g were divided into three groups each having ten (10) healthy mice. The first group was orally administrated with distilled water while the second and third groups were orally administrated with 50 mg/mL and 100 mg/mL respectively of acetamprid (0.1 mL) daily for one week. LD50 of acetamiprid was measured and found to be 200 mg/kg. The parameters of evaluations included liver function using Aspartate Aminotransferase (AST), Alanine Aminotransferase (ALT) and Alkaline Phosphatase (ALP). Lipid profile was anal
... Show MoreThis study aims to deliver the woman’s image and to unveil on how to be introduced in the TV series. The research is based on the survey method-using content analysis tool. The research sample represented in the TV series produced by the IMN, which were displayed in 2014 and used the pattern of Margaret Gallagher to analyze the content of the series in accordance with the frame analysis theory.
The study came up with declination of the woman’s representation compared with man in Iraqi TV drama, also the study finds that the series introduced the woman according to the personal, social, political, and economic frames in a standardizing method. It focuses on the characteristics always attributed to it as showing her obedient of the
Nano TiO2 thin films on glass substrates were prepared at a constant temperature of (373 K) and base vacuum (10-3 mbar), by pulsed laser deposition (PLD) using Nd:YAG laser at 1064 nm wavelength. The effects of different laser energies between (700-1000)mJ on the properties of TiO2 films was investigated. TiO2 thin films were characterized by X-ray diffraction (XRD) measurements have shown that the polycrystalline TiO2 prepared at laser energy 1000 mJ. Preparation also includes optical transmittance and absorption measurements as well as measuring the uniformity of the surface of these films. Optimum parameters have been identified for the growth of high-quality TiO2 films
... Show More