A procedure, depending on the derivatization and determination of aniline was depicted andvalidated in this study. 8-hydroxyquinoline (8-HQ) was used as the derivatizing agent for thedetermination of aniline. An optimization study was performed for the derivatization reaction, i.e.,the diazonium coupling reaction, the optimum parameters were as follows: 22 mM of hydrochloricacid, 54mM of sodium hydroxide, and 1.8mM of sodium nitrate. The optimization study of themethod of cloud point extraction (CPE) revealed that the extraction solvent was 0.5 ml of Triton X-100, the optimum temperature was 90 °C, and the incubation time was 25 min. The linearity,correlation coefficients, molar absorptivities, and limits of detection were improved using the CPEmethod. The extraction product was injected into HPLC. The chromatographic conditions were asfollows: the mobile phase was acetonitrile:water 60:40, the stationary phase was C18 RP column,the detection was at visible wavelength of 420 nm, flow rate 1ml/min. The proposed method wasapplied for the trace detection in environmental application of wastewater. The concentration ofaniline in wastewater was in range of 0.2-7 μg/l. (PDF) DETERMINATION OF ANILINE IN WASTEWATER BY CLOUD POINT EXTRACTION FOLLOWED BY HPLC USING 8- HYDROXYQUINOLINE AS A DERIVATIZATION AGENT. Available from: https://www.researchgate.net/publication/358078777_DETERMINATION_OF_ANILINE_IN_WASTEWATER_BY_CLOUD_POINT_EXTRACTION_FOLLOWED_BY_HPLC_USING_8-_HYDROXYQUINOLINE_AS_A_DERIVATIZATION_AGENT [accessed Mar 08 2025].
The adsorption of copper ions onto produced activated carbon from banana peels (with particle size 250 µm) in a single component system with applying magnetic field has been studied using fixed bed adsorber. The fixed bed breakthrough curves for the copper ions were investigated. The adsorption capacity for Cu (II) was investigated. It was found that 1) the exposure distance (E.D) and strength of magnetic field (B), affected the degree of adsorption; and 2) experiments showed that removal of Cu ions and accumulative adsorption capacity of adsorbent increase as the exposure distance and strength of magnetic field increase.
The corrosion behavior of carbon steel at different temperatures 100,120,140 and 160 Cͦ under different pressures 7,10 and 13 bar in pure distilled water and after adding three types of oxygen scavengers Hydroquinone, Ascorbic acid and Monoethanolamine in different concentrations 40,60 and 80 ppm has been investigated using weight loss method. The carbon steel specimens were immersed in water containing 8.2 ppm dissolved oxygen (DO) by using autoclave. It was found that corrosion behavior of carbon steel was greatly influenced by temperature with high pressure. The corrosion rate decreases, when adding any one of oxygen scavengers. The best results were obtained at a concentration of 80 ppm of each scavenger. It was observed that
... Show MoreHigh-performance liquid chromatographic methods are used for the determination of water-soluble vitamins with UV-Vis. Detector. A reversed-phase high-performance liquid chromatographic has been developed for determination of water-soluble vitamins. Identification of compounds was achieved by comparing their retention times and UV spectra with those of standards solution. Separation was performed on a C18 column, using an isocratic 30% (v/v) acetonitril in dionozed water as mobile phase at pH 3.5 and flow rate 1.0m/min. The method provides low detection and quantification limits, good linearity in a large concentration interval and good precision. The detection limits ranged from 0.01 to 0.025µg/ml. The accuracy of the method was
... Show MoreIn this paper, turbidimetric and reversed-phase ultra-fast liquid chromatography (UFLC) methods were described for the quantitative determination of ephedrine hydrochloride in pharmaceutical injections form. The first method is based on measuring the turbidimetric values for the formed yellowish white precipitate in suspension status in order to determine the ephedrine hydrochloride concentration. The suspended substance is formed as a result of the reaction of ephedrine hydrochloride with phosphomolybdic acid which was used as a reagent. The physical and chemical characteristics of the complex were investigated. The calibration graphs of ephedrine were established by turbidity method. While the second method (UFLC) was conducted using the
... Show MoreA chemometric method, partial least squares regression (PLS) was applied for the simultaneous determination of piroxicam (PIR), naproxen (NAP), diclofenac sodium (DIC), and mefenamic acid (MEF) in synthetic mixtures and commercial formulations. The proposed method is based on the use of spectrophotometric data coupled with PLS multivariate calibration. The Spectra of drugs were recorded at concentrations in the linear range of 1.0 - 10 μg mL-1 for NAP and from 1.0 - 20 μg mL-1 for PIR, DIC, and MEF. 34 sets of mixtures were used for calibration and 10 sets of mixtures were used for validation in the wavelength range of 200 to 400 nm with the wavelength interval λ = 1 nm in methanol. This method has been used successfully to quant
... Show MoreDiarrhea is one of the most commonly encountered minor ailments in the community pharmacies. It is associated with significant morbidity and mortality. However, the majority of pharmacists in Iraq did not manage diarrheal cases in a proper way. Therefore, the current study aimed to evaluate the benefit of a new mobile application (diarrhea management step by step) to improve the pharmacist's role in the management of diarrhea. The study was conducted from 21th September to 21th October 2021 using a pre-post design via a simulated patient (SP) technique. A validated diarrhea scenario was presented to each pharmacist by the SP twice, once before and the other after giving the mobile application to the pharmacist. Furthermore, pharmaci
... Show MoreThe aim of this study is to investigate the kinetics of copper removal from aqueous solutions using an electromembrane extraction (EME) system. To achieve this, a unique electrochemical cell design was adopted comprising two glass chambers, a supported liquid membrane (SLM), a graphite anode, and a stainless-steel cathode. The SLM consisted of a polypropylene flat membrane infused with 1-octanol as a solvent and bis(2-ethylhexyl) phosphate (DEHP) as a carrier. The impact of various factors on the kinetics constant rate was outlined, including the applied voltage, initial pH of the donor phase solution, and initial copper concentration. The results demonstrated a significant influence of the applied voltage on enhancing the rate of c
... Show MoreIn the light of the globalization Which surrounds the business environment and whose impact has been reflected on industrial economic units the whole world has become a single market that affects its variables on all units and is affected by the economic contribution of each economic unit as much as its share. The problem of this research is that the use of Pareto analysis enables industrial economic units to diagnose the risks surrounding them , so the main objective of the research was to classify risks into both internal and external types and identify any risks that require more attention.
The research was based on the hypothesis that Pareto analysis used, risks can be identified and addressed before they occur.
... Show MoreEquation Boizil used to Oatae approximate value of bladder pressure for 25 healthy people compared with Amqas the Alrotinahh ways used an indirect the catheter Bashaddam and found this method is cheap and harmless and easy