Preferred Language
Articles
/
PhZfL4cBVTCNdQwCZjxA
CFD Simulation of Heat Transfer Augmentation in a Circular Tube fitted with Alternative Axis Twisted Tape in Laminar Flow under the Constant Heat Flux
...Show More Authors

Publication Date
Sun Dec 03 2017
Journal Name
Baghdad Science Journal
The Efficiency of Using Ozone Gas and Heat to Control Larvae and Adult Stage of Red Flour Beetle, Tribolium castaneum (Herbst) (Coleoptera: Tenebrionidae)
...Show More Authors

The effect of ozone gas with temperatures 35. 40 and 45 Celsius to control on larval and adult stages of Tribolium castaneum was tested and at time of exposure 1.0, 3.0, 7.0, 9.0, 11.0, 13.0 hours and the level of relative humidity prevailing during the test 45 ± 1%. Results showed significant differences between the exposure times, when the percentage of mortality 100% between larvae (primary, intermediate and advanced) in the treatment effect at a temperature of 35 Celsius with ozone gas at exposure time to 9.0, 11.0, 11.0 hours for the three ages respectively, and adult (male and female) in the same treatment when the three heat degrees had given ratios the total mortality reached 100% of both males at exposure time to 7.0 ,3

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Sun Dec 01 2024
Journal Name
Journal Of Economics And Administrative Sciences
Nadaraya-Watson Estimation of a Circular Regression Model on Peak Systolic Blood Pressure Data
...Show More Authors

Purpose: The research aims to estimate models representing phenomena that follow the logic of circular (angular) data, accounting for the 24-hour periodicity in measurement. Theoretical framework: The regression model is developed to account for the periodic nature of the circular scale, considering the periodicity in the dependent variable y, the explanatory variables x, or both. Design/methodology/approach: Two estimation methods were applied: a parametric model, represented by the Simple Circular Regression (SCR) model, and a nonparametric model, represented by the Nadaraya-Watson Circular Regression (NW) model. The analysis used real data from 50 patients at Al-Kindi Teaching Hospital in Baghdad. Findings: The Mean Circular Erro

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Dec 01 2019
Journal Name
2019 First International Conference Of Computer And Applied Sciences (cas)
Influence of Peristaltic Flow And Brownian Motion Of Jeffery Nanofluid In A Tapered Asymmetric Channel
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Tue Dec 03 2013
Journal Name
Al-kindy College Medical Journal
The Role of Tibialis Posterior Tendon Transfer in Correction of Foot Drop Deformity
...Show More Authors

Backgr ound: The transfer of the tibialis posterior tendon to the anterior aspect of the ankle not only replaces the function of the paralyzed muscles, but also removes the deforming force on the medial aspect of the foot. Objecti ves: In this study, we evaluated patients who underwent tibialis posterior tendon transfer for the treatment of foot drop, and comparison through interosseous membrane route versus anterior to lower tibia route of tibialis posterior tendon transfer, with evaluation of the results according to carayon criteria Methods: Nine patients with foot drop secondary to different causes treated with tibialis posterior tendon transfer from January 2011 to January 2012 were followed up for a mean of 12 months in Al Kindy Teach

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 30 2013
Journal Name
Al-kindy College Medical Journal
The Role of Tibialis Posterior Tendon Transfer in Correction of Foot Drop Deformity
...Show More Authors

Bac kground: The transfer of the tibialis posterior tendon to the anterior aspect
of the ankle not only replaces the function of the paralyzed muscles, but also
removes the deforming force on the medial aspect of the foot.
Objec t i ves : In this study, we evaluated patients who underwent tibialis
posterior tendon transfer for the treatment of foot drop, and comparison through
interosseous membrane route versus anterior to lower tibia route of tibialis
posterior tendon transfer, with evaluation of the results according to carayon
criteria
Methods: Nine patients with foot drop secondary to different causes treated with
tibialis posterior tendon transfer from January 2011 to January 2012 were
followed up for a

... Show More
View Publication Preview PDF
Publication Date
Sat Aug 01 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Simulation of Sediment Transport in the Upper Reach of Al-Gharraf River
...Show More Authors
Abstract<p>For the past few years, the sediment began to accumulate in Al-Gharraf River which reduces the flow capacity of the River. In the present research, a numerical model was developed using Hec-Ras software, version 5.0.4. to simulate the flow and sediment transport in the upper reach of the river. The hydrological and cross-section data measured by the Ministry of Water Resources, for the reach located between Kut and Hai cities and having a length of 58200 m, was used to perform calibration and verification of the model. Moreover, field sampling of suspended and bed loads was gathered for five months starting from 7/2/2019, and laboratory tests of samples were conducted to be used as in</p> ... Show More
View Publication
Scopus (9)
Crossref (1)
Scopus Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Food Science And Technology
Analyzing food production risk with Monte Carlo simulation
...Show More Authors

View Publication
Scopus (3)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Sun Dec 04 2011
Journal Name
Baghdad Science Journal
Dopping Effect on Optical Constant of Poly (Vinyl Chloride)
...Show More Authors

Thick films of poly(vinyl chloride)(PVC)& PVC doped with Zn(etx)2 salt complex have been prepared by cast method with fixed thickness almost (120±5) Microns. Optical studies were carried out in the wavelengths region(200-900)nm based on absorption & transmition measurement. Optical parameters such as absorption coefficient(?) ,refraction index(n) and extinction coefficient(K) were observed to be effected by adding the dopant.Electrical parameters such as real(?)& imaginary(?) part of dielectric constant were also calculated part of dielectric constant were also calculated from the optical parameters using Maxwell equation.

View Publication Preview PDF
Crossref
Publication Date
Fri Dec 23 2022
Journal Name
Innovative Infrastructure Solutions
Experimental modeling of a single pile in liquefiable soil under the effect of coupled static-dynamic loads
...Show More Authors

In this work, a single pile is physically modeled and embedded in an upper liquefiable loose sand layer overlying a non-liquefiable dense layer. A laminar soil container is adopted to simulate the coupled static-dynamic loading pile response during earthquake motions: Ali Algharbi, Halabjah, El-Centro, and Kobe earthquakes. During seismic events with combined loading, the rotation along the pile, the lateral and vertical displacements at the pile head as well as the pore pressure ratio in loose sandy soil were assessed. According to the experimental findings, combined loading that ranged from 50 to 100% of axial load would alter the pile reaction by reducing the pile head peak ground acceleration, rotation of the pile, and lateral displacem

... Show More
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sun Oct 21 2018
Journal Name
Al-kindy College Medical Journal
Evaluation of the clinical examination in thediagnosis of acute medial collateral ligament injury of the knee joint in comparism with examination under general anesthesia
...Show More Authors

Background: Tear of MCL of the knee is a frequent problem among knee ligaments injuries.Injuries to the MCL are usually caused by contact on the outside of the knee and are accompanied by sharp pain on the inside of the knee. Contrary to most other knee ligaments the medial collateral ligament (MCL) has an excellent ability to heal, being fairly large and well vascularised structure. The vast majority of isolated medial ligament injuries heal without significant long-term problems

Objectives: is to compare between the early clinical examination, and assessment under general anesthesia (GA), and to find out the best methods to assess the MCL tear especially in suspected cases.

Type

... Show More
View Publication Preview PDF
Crossref