The heat exchanger is a device used to transfer heat energy between two fluids, hot and cold. In this work, an output feedback adaptive sliding mode controller is designed to control the temperature of the outlet cold water for plate heat exchanger. The measurement of the outlet cold temperature is the only information required. Hence, a sliding mode differentiator was designed to estimate the time derivative of outlet hot water temperature, which it is needed for constructing a sliding variable. The discontinuous gain value of the sliding mode controller is adapted according to a certain adaptation law. Two constraints which imposed on the volumetric flow rate of outlet cold (control input) were considered within the rules of the proposed adaptation law in this work. These are the control input is a positive quantity, and it limited by a maximum value. The maximum allowable desired outlet cold water has been estimated as function of heat exchanger parameters and maximum control input. The simulation results demonstrate the performance of the proposed adaptive sliding mode control where the outlet cold water was forced to follow desired temperature equal to 45𝑜 . Additionally, the robustness of the proposed controller was tested for the case where the cold water inlet temperature is not constant, and also for the case of heat exchanger parameters uncertainty. The results were revealed the robustness of the proposed controller.
The simulation have been made for 3D flow structure and heat transfer with and without
longitudinal riblet upstream of leading edge vane endwall junction of first stage nozzle guide vane .The research explores concept of weakening the secondary flows and reducing their harmful effects.Numerical investigation involved examination of the secondary flows ,velocity and heat transfer rates by solving the governing equations (continuity, Navier -stokes and energy equations ) using the known package FLUENT version (12.1).The governing equations were solved for three dimentional, turbulent flowe, incompressible with an appropriate turbulent model (k-ω,SST) .The numerical solution was carried out for 25 mode
... Show MoreBackground: Coronavirus pandemic (COVID-19) has enormously affected various healthcare services including the one of community pharmacy. The ramifications of these effects on Iraqi community pharmacies and the measures they have taken to tackle the spread of COVID-19 is yet to be explored. In this cross sectional survey, infection control measures by community pharmacies in Sulaimani city/Iraq has been investigated.
Methods: Community pharmacists were randomly allocated to participate in a cross-sectional survey via visiting their pharmacies and filling up the questionnaire form.
Results and discussion:
... Show MoreSimplification of new fashion design methods
Design and construction of video extractor circuit require an understanding of several parameters, which include: Selector circuit, extracting circuit which contains sampling signal and multiplexing. At each radar pulse, the video signal is fed to one of the selector. The fast filter has a pass –band from 190 Hz to 1800 Hz. These frequencies correspond to targets having radial velocities laying between and 10 Kph and 200 Kph.Slow filter: 60 Hz to 230 Hz for radial velocities laying between 3.5 and 13 Kph.The video- extractor is organized in four PCB CG (A-B-C-D) each one having 16 selector. The sampling signal (ADS) (1-2-3-4) control the 4-line-to-16-line decoders. 8 multiplexers of 8 inputs each, are required for the multiplexing of the
... Show MoreIn this work the design and construction of a flash photolysis pulsed HCl laser was presented. The parameters of the pumping source and discharge current density was obtained, which sufficient to shift the flash lamp spectrum towards uv portion of spectrum. The maximum pulse laser energy parameters was measured. Total pressure and ratio of active gases to optimized the output pulse energy were measured , where at 125 mbar of total pressure and 1:7:14 Cl2:H2: He ratio, the laser energy was measured to be 200 mJ at pumping four flash lamps energy in the order of 6400J .The resonator consists of copper a near hemispherical mirror with the radius of curvature 3m coated by gold and reflectivity 98%,the output coupler sapphire mirror of
... Show MoreReduction represents a form of artistic abstraction to express things with formal symbols that suggest the content of the idea, as the beauty of the design artwork cannot be unique in the form only, but in revealing its meaning as well. He resorts to shorthand to express the content of his idea related to design necessities and needs to achieve a specific function whose role is crystallized through the form that follows the function. The importance of the research was also represented in: Benefiting workers and scholars in the field of design with regard to shorthand and implicit in graphic design. The aim of the research: to identify the relationship between implicit meaning and reduced forms in graphic design. And the aesthetic of fo
... Show MoreForecasting has become common process and reality. Since man has found multiple forms of simple predictive predictions, fruitful predictive results have emerged, such as weather forecasting or trading on stock exchange. The research was organized by defining the problem, which was manifested by the question:
(What is the prediction in global logo design methods?)
The aim of the research: (revealing design prediction in the methods of global logos). The theoretical framework was: (the concept of prediction in the design of global logos), (methods of global logos), (types of prediction) and then were attached to indicators, results and conclusions, including:
- The color value of international logos came with human needs: a
In this work the design and construction of optical pumping system was presented. The parameters of the pumping source to obtain discharge current density sufficient to shift the flash lamp spectrum towards uv portion of spectrum were measured.The current density was supplied to the flash lamp must be greater than 4000Amp./cm2 to obtain the spectral range wavelength lies between 0.2 and 0.35?m. The current density was obtained by a capacitor 50?F, at 7KV discharge voltage. The applied electrical energy to the flash lamp was more than 1200 J, and the current density was around 5000 Amp./cm2.The electrical parameters of the flash lamp were calculated. The impedance parameters(K0) from the voltage and the peak current pulse was measured in ran
... Show More