This study aims to evaluate the biocompatibility of a novel filler material intended to improve the longevity of polymer systems used in prosthetics in respect of cytotoxicity and skin irritation. RTV50F silicone elastomer incorporated with various percentages of hexagonal boron nitride (H-BN) (0.1, 0.3, 0.5, 0.7, and 1 wt%) have been tested. Silicone without H-BN was utilized as the control for comparison. The in vitro cytotoxicity test includes specimens (n=18) with 10 mm in diameter and 2 mm in thickness applied directly to the normal human fibroblast cell line (NHF) and incubated for 72 hours, then 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay was used to determine the cell viability. The skin irritation test was conducted in vivo, in which specimens (n=12) with 25 mm × 25 mm dimensions were applied on the back of 5 different rabbits for 4 hours, then the skin response was evaluated after 24, 48, and 72 hours. The acquired in vitro data were statically analyzed using one-way ANOVA and post-hoc Tukey’s tests with GraphPad Prism 8, where P-value < 0.05 was considered statistically significant. The H-BN powder and silicone specimens were studied via field emission scanning electron microscopy (FE-SEM). The results revealed a negligible effect of maxillofacial silicone on cell viability after 72 hours of incubation, only one group (1wt%) showed a significant difference compared to the control group but the toxicity percentage didn’t exceed 30% of cell viability and there was no skin irritation during the in vivo test.
To find out a simple and efficient equation to estimate maize ear grain weight on farm (in situ), twenty three maize crosses along with two synthetics were grown in the field. On the experimental farm of the Dept. of Field Crop Sci., College of Agric., Univ. of Baghdad, seeds of twenty five maize genotypes were grown in the fall season of 2013 with three replicates. At dough stage of the kernels, five naked ears of each experimental units were measured for length and maximum diameter. This will sum up 125 ears of the trial. The volumes of ears were calculated as cylinder (length× r2× 3.1416). Grain weight of all ears were determined after harvesting and drying to 15% grain moisture. A constant was calculated by dividing ear grain weight b
... Show MoreIn this research, a modified artificial hand with direct control has been designed using electrical artificial muscle wires that receive direct sensory impulses through human hand instead of using the mechanical action to open and close this artificial hand. Each finger is designed as a chain and its movements achieved through the conventional arrangement control of the electrical muscles wires. The results indicate that it is possible to design an artificial hand using electrical muscle wire for control it with high accuracy.
Abstract
Pneumatic processes sequence (PPS) is used widely in industrial applications. It is common to do a predetermined PPS to achieve a specific larger task within the industrial application like the PPS achieved by the pick and place industrial robot arm. This sequence may require change depending on changing the required task and usually this requires the programmer intervention to change the sequence’ sprogram, which is costly and may take long time. In this research a PLC-based PPS control system is designed and implemented, in which the PPS is programmed by demonstration. The PPS could be changed by demonstrating the new required sequence via the user by following simple series of manual steps without h
... Show MoreIn this research estimated the parameters of Gumbel distribution Type 1 for Maximum values through the use of two estimation methods:- Moments (MoM) and Modification Moments(MM) Method. the Simulation used for comparison between each of the estimation methods to reach the best method to estimate the parameters where the simulation was to generate random data follow Gumbel distributiondepending on three models of the real values of the parameters for different sample sizes with samples of replicate (R=500).The results of the assessment were put in tables prepared for the purpose of comparison, which made depending on the mean squares error (MSE).
The present work describes numerical and experimental investigation of the heat transfer characteristics in a plate-fin, having built-in piezoelectric actuator mounted on the base plate (substrate). The geometrical configuration considered in the present work is representative of a single element of the plate-fin and triple fins. Air is taken as the working fluid. A performance data for a single rectangular fin and triple fins are provided for different frequency levels (5, 30 and
50HZ) , different input power (5,10,20,30,40 and 50W) and different inlet velocity (0.5, 1, 2, 3, 4, 5 and 6m/s) for the single rectangular fin and triple fins with and without oscillation. The investigation was also performed with different geometrical fin