Background: Because of the disturbance in the pituitary gland, growth hormone (GH) secretion will be increased and, as a result, insulin-like growth factor 1 (IGF-1) secretion will be increase as well, leading to a chronic and rare disease called acromegaly disease. One of the most serious complications of acromycaly is diabetes. Insulin resistance, which causes diabetes, occurs in the body because of increased growth hormone secretion Objective: The aim of this work is to estimate some biochemical parameters. These parameters were not studied extensively in the literature such as BALP and LOX and the possibility of using LOX as a new biomarker for acromyalgic patients with diabetic. Patients and Methods: The study was performed on (25) male as patients with active acromegaly and those with type 2 diabetes mellitus, aged between (40-60) years, and (25) male aged between (40-60) years as control group. Blood was collected and serum was separated. Enzyme-linked immune sorbent assay (ELISA) technique was used to determine the GH, IGF-1, BLAP, and LOX. By using enzymatic colorimetric method (Glucose oxidase-peroxidase), fasting serum glucose (FSG) was estimated. MDA and TAC were estimated by colorimetric methods as well. Results: The results showed that there were significant differences among GH, IGF-1, FSG, BLAP, LOX, and MDA when compared between patients and control group, while TAC showed a significant decrease between patients and healthy group (p < 0.05).
A newly developed analytical method was conducted for the determination of Ketotifen fumarate (KTF) in pharmaceuticals drugs via quenching of continuous fluorescence of 9(10H)-Acridone (ACD). The method was applied using flow injection system of a new homemade ISNAG fluorimeter with fluorescence measurements at ± 90◦ via 2×4 solar cell. The calibration graph was linear in the range of 1-45 mmol/L, with correlation coefficient r = 0.9762 and the limit of detection 29.785 µg/sample from the stepwise dilution for the minimum concentration in the linear dynamic ranged of the calibration graph. The method was successfully applied to the determination of Ketotifen fumarate in two different pharma
... Show MoreAn easy, eclectic, precise high-Performance Liquid Chromatographic (HPLC) procedure was evolved and validated to estimate of Piroxicam and Codeine phosphate. Chromatographic demarcation was accomplished on a C18 column [Use BDS Hypersil C18, 5μ, 150 x 4.6 mm] using a mobile phase of methanol: phosphate buffer (60:40, v/v, pH=2.3), the flow rate was 1.1 mL/min, UV detection was at 214 nm. System Suitability tests (SSTs) are typically performed to assess the suitability and effectiveness of the entire chromatography system. The retention time for Piroxicam was found to be 3.95 minutes and 1.46 minutes for Codeine phosphate. The evolved method has been validated through precision, limit of quantitation, specificity,
... Show MoreA simple, low cost and rapid flow injection turbidimetric method was developed and validated for mebeverine hydrochloride (MBH) determination in pharmaceutical preparations. The developed method is based on forming of a white, turbid ion-pair product as a result of a reaction between the MBH and sodium persulfate in a closed flow injection system where the sodium persulfate is used as precipitation reagent. The turbidity of the formed complex was measured at the detection angle of 180° (attenuated detection) using NAG dual&Solo (0-180°) detector which contained dual detections zones (i.e., measuring cells 1 & 2). The increase in the turbidity of the complex was directly proportional to the increase of the MBH concentration
... Show MoreA simple, low cost and rapid flow injection turbidimetric method was developed and validated for mebeverine hydrochloride (MBH) determination in pharmaceutical preparations. The developed method is based on forming of a white, turbid ion-pair product as a result of a reaction between the MBH and sodium persulfate in a closed flow injection system where the sodium persulfate is used as precipitation reagent. The turbidity of the formed complex was measured at the detection angle of 180° (attenuated detection) using NAG dual&Solo (0-180°) detector which contained dual detections zones (i.e., measuring cells 1 & 2). The increase in the turbidity of the complex was directly proportional to the increase of the MBH concentration
... Show Moreطريقة سهلة وبسيطة ودقيقة لتقدير السبروفلوكساسين في وجود السيفاليكسين او العكس بالعكس في خليط منهما. طبقت الطريقة المقترحة بطريقة الاضافة القياسية لنقطة بنجاح في تقدير السبروفلوكساسين بوجود السيفاليكسين كمتداخل عند الاطوال الموجية 240-272.3 نانوميتر وبتراكيز مختلفة من السبروفلوكساسين 4-18 مايكروغرام . مل-1 وكذلك تقدير السيفاليكسين بوجود السبروفلوكساسين الذي يتداخل باطوال موجية 262-285.7 نانوميتر وبتراكيز مخ
... Show MoreThe presence of a single complex adaptive weight in each element channel of an adaptive array antenna is sufficient for processing of narrowband signals. The ability of an adaptive array antenna to null interference deteriorates rapidly as the interference bandwidth increases. The performance of narrowband adaptive array antenna with LMCV Beamforming algorithm is examined. The interaction effects between received signal angle of arrival and array parameters like the interelement spacing and the number of array element and the received signal bandwidth were studied. The output Signal to Interference plus Noise Ratio (SINR) and Interference to Noise Ratio (INR) are used as performance parameters for evaluation of these effects. It is found
... Show More This study includes Estimating scale parameter, location parameter and reliability function for Extreme Value (EXV) distribution by two methods, namely: -
- Maximum Likelihood Method (MLE).
- Probability Weighted Moments Method (PWM).
Used simulations to generate the required samples to estimate the parameters and reliability function of different sizes(n=10,25,50,100) , and give real values for the parameters are and , replicate the simulation experiments (RP=1000)
... Show MoreBackground: There are various secreted proteins affecting the prognosis of oral squamous cell carcinoma (OSCC) and one of them is Angiopoietin-2(Ang-2) which is thought to have an essential role in the development and progression of the tumor. Aim of the study: This study was conducted to determine the expression of (Ang-2) in (OSCC) to assess its correlations with clinicopathological parameters of the tumor. Material and Methods: 36 formalin- fixed, paraffin- embedded tissue blocks histologically diagnosed as OSCC were examined for Ang-2 immunohistochemical expression semi quantitively. Results: The expression of Ang-2 was significantly associated with histopathological grade (P value=0.023), while there is no significant association wi
... Show More