AW Ali T, Journal of the Faculty of Medicine, 2015 - Cited by 3
It is shown that if a subset of a topological space (χ, τ) is δ-semi.closed, then it is semi.closed. By use this fact, we introduce the concept regularity of a topological space (χ, τ) via δ-semi.open sets. Many properties and results were investigated and studied. In addition we study some maps that preserve the δ-semi.regularity of spaces.
In this work we explain and discuss new notion of fibrewise topological spaces, calledfibrewise soft ideal topological spaces, Also, we show the notions of fibrewise closed soft ideal topological spaces, fibrewise open soft ideal topological spaces and fibrewise soft near ideal topological spaces.
W Tarik A, AW Ali T, Journal of the Faculty of Medicine, 2015 - Cited by 2
Background: Menopause can bring oral health problems and also associated with significant adverse changes in the orofacial complex. After menopause, women become more susceptible to periodontal disease due to deficiency of estrogen hormone. Current study aimed to evaluate the periodontal health status in relation to salivary constituent including pH, flow rate and some elements (Magnesium, Calcium and inorganic phosphorus) of pre and post-menopause women. Materials and Methods: Periodontal health status of 52 women aged 48-50 years old (26 pre-menopause and 26 post-menopause) were examined including (gingival index, plaque index, calculus index, probing pocket depth and clinical attachment level). Salivary sample was collected for two women
... Show MoreWarfarin dosing is challenging due to a multitude of factors affecting its pharmacokinetics (PK) and pharmacodynamics (PD). A novel personalised dosing algorithm predicated on a warfarin PK/PD model and incorporating CYP2C9 and VKORC1 genotype information has been developed for children. The present prospective, observational study aimed to compare the model with conventional weight-based dosing. The study involved two groups of children post-cardiac surgery: Group 1 were warfarin naïve, in whom loading and maintenance doses were estimated using the model over a 6-month duration and compared to historical case-matched controls. Group 2 were already established on maintenance therapy a
Explanation of article events , or discribing it establish to anderstanding an phenomenon which its effects still clear in the art , surching like this may be very usful in the analysis of new art , which considering one of the most important turns in the history of art . and if we look to human body in the art as existenc in the art , from it’s begening to the modern age . so we can understand the meaning of this existence and it’s directins which cover all the worid and the lead us to thiories and suggestion’s help in understand to this direction and the effects between our arts and the external directions.
The purpose of this study is to avoid delays and cost changes that occur in emergency reconstruction projects especially in post disaster circumstances. This study is aimed to identify the factors that affect the real construction period and the real cost of a project against the estimated period of construction and the estimated cost of the project. The case study is related to the construction projects in Iraq. Thirty projects in different areas of construction in Iraq were selected as a sample for this study. Project participants from the projects authorities provided data about the projects through a data collection distributed survey made by the authors. Mathematical data analysis was used to construct a model to predict change
... Show MoreThis paper presents a study to investigate the behavior of post-tensioned segmental concrete beams that exposed to high-temperature. The experimental program included fabricating and testing twelve simply supported beams that divided into three groups depending on the number of precasting concrete segments. All specimens were prepared with an identical length of 3150 mm and differed in the number of the incorporated segments of the beam (9, 7, or 5 segments). To simulate the genuine fire disasters, nine out of twelve beams were exposed to a high-temperature flame for one hour. Based on the standard fire curve (ASTM – E119), the temperatures of 300◦C (572◦F), 500◦C (932◦F), and 700◦C (1292◦F) were adopted. Consequently,
... Show MoreIn this study, the response of ten composite post-tensioned concrete beams topped by a reinforced concrete deck with adequate reinforcing shear connectors is investigated. Depending on the concrete compressive strength of the deck slab (20, 30, and 40 MPa), beams are grouped into three categories. Seven of these beams are exposed to a fire attack of 700 and 800 °C temperature simultaneously with or without the presence of a uniformly distributed sustained static loading. After cooling back to ambient temperature, these composite beams are loaded up to failure, using a force control module, by monotonic static loading in a four-point-bending setup with two symmetrical concentrated loads applied in