Our aim was to investigate the changes in the myocardium stiffness index for patients suffering from systemic hypertension, and to assess their left ventricular performance. We studied 263 hypertensive patients and 166 healthy subjects as a control group. By using conventional Doppler echocardiography, the following parameters were measured—Left ventricular end diastolic diameter, left ventricular end systolic diameter, transmitral early velocity, isovolumic relaxation time, and isovolumic contraction time. Tissue Doppler imaging (TDI) was used in the measurements of the early mitral annular velocity (Ea) and the diastolic stiffness was obtained by calculating the ratio E\Ea\LVIDd. Index myocardial performance (IMP) was calculated according to following equation (IVCT + IVRT)/ET for both the control group and hypertensive group. Results reveal that the differences in the average value of transmitral early filling velocity (E) between patients and control groups for age range (20 - 49) and (50 - 80) were (−1.91%) and (−3.69%) respectively with p value >0.05 for both groups, and the changes in LVIDd between patients and control groups were 0.42% and 1.29% for age ranges (20 - 49) and (50 - 80) respectively with p value >0.05 for both age groups. A significant difference in IMP between patients and controls has also been observed and the changes were 29.54% and 30.43% for age range (20 - 49) and (50 - 80) respectively with p value <0.05 for both groups. The mean values for E/Ea ratio and for the measured LV stiffness index were significantly higher in hypertensive patients compared with control group (p value < 0.05) for both age groups. In conclusion, LV myocardial diastolic stiffness index and IMP are increased in hypertensive patients.
In this paper, simulation study of the frequency shift of photonic bandgaps due to refractive index scaling using liquids filled hollow-core photonic crystal fibers is presented. Different liquids (distilled water, n-hexane, methanol, ethanol and acetone) are used to fill the cladding of 2 types of hollow core photonic crystal fibers (HC19-1060, HC7-1060). These liquids are used to change the effective index scaling and index contrast of the cladding. The effect of increasing temperature of the liquid (20-100 0C for water and 20-70 0C for other liquids ) infiltrated hollow core fiber on the bandgap width and transmission properties has been computed. The maximum photonic bandgap width at 0.0243 has appeared with filling HC7-1060 PCF with
... Show MoreRecently, environmental noise has arisen from various sources, such as those from exhaust mufflers of combustion engines found in cars, trucks, or power generators, which produce significant noise during their operation. Controlling the radiated noise from these mufflers is a major factor in improving acoustic comfort and minimizing the impact on the surrounding communities. Numerous research has been presented for this reason by modification of the internal structure of the exhaust muffler. The main objective of this work is to reduce the noise level emitted from exhaust mufflers. This can be achieved by adjusting structure parameters to attenuate the surrounding environment's radiated noise. Analysis of pressure-wave propagation h
... Show MoreUnstable angina pectoris often leads to acute myocardial infarction. Since uric acid is thought to be risk factor for cardiovascular disease and considered a major antioxidant in human blood .The level of uric acid and lipid peroxidation in the sera of patients with unstable angina and myocardial infarction were measured and compared to the healthy individuals. Twenty-nine patients with unstable angina and twenty-nine patients with myocardial infarction were studied and compared to twenty-five healthy individuals. Uric acid was measured by using Human Kit. Malondialdelyde (MDA) a lipid peroxidation marker, was measured by thiobarbituric acid method .Significant elevation of uric acid and MDA were observed in the sera of pati
... Show MoreThis work presents a simple method for determination of the neutron reflection coefficient (n) as a function of different neutron reflector materials.A laboratory neutron source (Am-Be) with activity of 16 ci is employed with a (BF3) neutron detector. Am-BeThree types of reflector materials are used as samples, the thickness of each sample is (5cm).It is found that( ?7) is: -For polyethlyene = 0.818
Concrete columns with hollow-core sections find widespread application owing to their excellent structural efficiency and efficient material utilization. However, corrosion poses a challenge in concrete buildings with steel reinforcement. This paper explores the possibility of using glass fiber-reinforced polymer (GFRP) reinforcement as a non-corrosive and economically viable substitute for steel reinforcement in short square hollow concrete columns. Twelve hollow short columns were meticulously prepared in the laboratory experiments and subjected to pure axial compressive loads until failure. All columns featured a hollow square section with exterior dimensions of (180 × 180) mm and 900 mm height. The columns were categorized into
... Show MoreIn this study, the flexural performance of a new composite beam–slab system filled with concrete material was investigated, where this system was mainly prepared from lightweight cold-formed steel sections of a beam and a deck slab for carrying heavy floor loads as another concept of a conventional composite system with a lower cost impact. For this purpose, seven samples of a profile steel sheet–dry board deck slab (PSSDB/PDS) carried by a steel cold-formed C-purlins beam (CB) were prepared and named “composite CBPDS specimen”, which were tested under a static bending load. Specifically, the effects of the profile steel sheet (PSS) direction (parallel or perpendicular to the span of the specimen) using different C-purlins c
... Show MoreThe current study aimed to isolate and diagnose the fungi associated with the inflammatory bowel disease patients with 150 samples distributed between 50 samples from Crohn's patients and 50 samples from ulcerative colitis patients, 50 control from Al-Kindy Al Teaching Hospital in Baghdad, Baghdad. Five types of yeast were isolated and identified, namely C. albicans, C.glabarta, Tropicales, C. parapsilosis, C. and C., krusi C. parapsilosis and.and Aspergillus, Penicillium, Muocer, Rhizopous, Saccharomycosis, and Cryptococcus, The results indicated the dominance of Candida spp. In crohn’s disease, the frequency of isolated Candida albicans was 24 (58.54%), Candida glabrata 11 (26.86%), Candida tropicalis 5 (12.2%) and Candida krusi was 1 (
... Show More