Our aim was to investigate the changes in the myocardium stiffness index for patients suffering from systemic hypertension, and to assess their left ventricular performance. We studied 263 hypertensive patients and 166 healthy subjects as a control group. By using conventional Doppler echocardiography, the following parameters were measured—Left ventricular end diastolic diameter, left ventricular end systolic diameter, transmitral early velocity, isovolumic relaxation time, and isovolumic contraction time. Tissue Doppler imaging (TDI) was used in the measurements of the early mitral annular velocity (Ea) and the diastolic stiffness was obtained by calculating the ratio E\Ea\LVIDd. Index myocardial performance (IMP) was calculated according to following equation (IVCT + IVRT)/ET for both the control group and hypertensive group. Results reveal that the differences in the average value of transmitral early filling velocity (E) between patients and control groups for age range (20 - 49) and (50 - 80) were (−1.91%) and (−3.69%) respectively with p value >0.05 for both groups, and the changes in LVIDd between patients and control groups were 0.42% and 1.29% for age ranges (20 - 49) and (50 - 80) respectively with p value >0.05 for both age groups. A significant difference in IMP between patients and controls has also been observed and the changes were 29.54% and 30.43% for age range (20 - 49) and (50 - 80) respectively with p value <0.05 for both groups. The mean values for E/Ea ratio and for the measured LV stiffness index were significantly higher in hypertensive patients compared with control group (p value < 0.05) for both age groups. In conclusion, LV myocardial diastolic stiffness index and IMP are increased in hypertensive patients.
Two‐dimensional buoyancy‐induced flow and heat transfer inside a square enclosure partially occupied by copper metallic foam subjected to a symmetric side cooling and constant heat flux bottom heating was tested numerically. Finite Element Method was employed to solve the governing partial differential equations of the flow field and the Local Thermal Equilibrium model was used for the energy equation. The system boundaries were defined as lower heated wall by constant heat flux, cooled lateral walls, and insulated top wall. The three parameters elected to conduct the study are heater length (7 ≤
This article presents and explores the theoretical aspect in the use of Arab Islamic theme by the western writers to obtain and achieve individual motives. In this study the model for the theory of Arab presence in Andalusia , through the book entitled “ Alhamra” by the English writer Washington Erving ,was analyzed.
The most important results in this research: the success of the author in the employment of the Islamic history in the formation of the first American legend, Columbus legend, through the selection of the right thoughts to establish his American National theory. The author compared between the Andalusia experience and the Arab occupation to Spain and the American conquest of the new
... Show MoreA field-pilot scale slow sand filter (SSF) was constructed at Al-Rustamiya Sewage Treatment Plant (STP) in Baghdad city to investigate the removal efficiency in terms of Biochemical Oxygen Demand (BOD5), Chemical oxygen demand (COD), Total Suspended Solids (TSS) and Chloride concentrations for achieving better secondary effluent quality from this treatment plant. The SSF was designed at a 0.2 m/h filtration rate with filter area 1 m2 and total filter depth of 2.3 m. A filter sand media 0.35 mm in size and 1 m depth was supported by 0.2 m layer of gravel of size 5 mm. The secondary effluent from Al-Rustamiya STP was used as the influent to the slow sand filter. The results showed that the removal of BOD5, COD, TSS, and Chloride were
... Show MoreThe international reporting auditor witness rapidly developed over the past years, where profession began give attention to the development of auditor reporting and improve its informational report through the issuance and amendment of some relevant international auditing standards. The reality of the situation refers to the failure to inform the auditor in Iraq in many areas, including: Clearly defined management responsibility for the preparation of financial and auditor's responsibility to express an opinion on these statements and Amendment of opinion when the financial statements as a whole is free from material misstatement based on the evidence is sufficient and appropriate audit, or not to build the auditor's ability to obt
... Show MoreThe research aimed to identify the level of job security, the level of sports institutional performance, and the relationship, contribution and impact of job security to sports institutional performance from the point of view of workers in the Iraqi Ministry of Youth and Sports. The descriptive approach was adopted in the manner of correlational relationships on a sample of (400) individuals who were randomly selected by (33.333%) of the employees working in the institutions at the headquarters of the Ministry of Youth and Sports, amounting to a total of (2293) individuals for the sports season (2022-2023), and they are naturally distributed among (13) main institutions in the formations of the headquarters of this ministry, and after adopt
... Show More
This study is concerned with the reality of total quality management and its role in achieving the excellence performance of the employees of the Institute of Technology / Baghdad, excellence performance is described by the extent to which the organization is able to invest the effort of the human resource to achieve its Objectives by adopting the principles of Total Quality Management (TQM) according to some of its basic dimensions in proportion to the reality and Possibilities Institute, the aim is to study to know the reality of total quality management ,and indicate the levels of excellence performance in the Institute of Technology / Baghdad,
... Show More
The work of this paper is an investigation to improve the condenser performance of the automobile air conditioning system by enhancing the air-side heat transfer from the condenser through the use of an air guide net installed in front of the condenser face which is basically an aluminum plate having a circular entrance shape for the air passage. The A/C system was examined under two types of test. The first test was conducted the air guide net, while the second was done with the air guide net. The performances of the A/C system under these tests were compared. For the second type of test, the experiment was carried out with three different size of air guide net, three different circular diameters (2, 3 and 3.5 cm) a
... Show More