This study examines the removal of ciprofloxacin in an aqueous solution using green tea silver nanoparticles (Ag-NPs). The synthesized Ag-NPs have been classified by the different techniques of SEM, AFM, BET, FTIR, and Zeta potential. Spherical nanoparticles with average sizes of 32 nm and a surface area of 1.2387m2/g are found to be silver nanoparticles. The results showed that the ciprofloxacin removal efficiency depends on the initial pH (2.5-10), CIP (2-15 mg/L), temperature (20-50°C), time (0-180 min), and Ag-NPs dosage (0.1-1g/L). Batch experiments revealed that the removal rate with ratio (1:1) (w/w) were 52%, and 79.8% of the 10 mg/L of CIP at 60, and 180 minutes, respectively with optimal pH=4. Kinetic models for adsorption and ciprofloxacin mechanism removal were also investigated, and kinetic analyzes showed adsorption to be a 3.8727kJ.mol-1 activation energy physical adsorption mechanism. The kinetic removal process, due to the low activation energy of 14.0606kJ.mol-1, is preferred the model of first-order after a physical diffusion-controlled reaction. Adsorption information from Langmuir, Freundlich, Temkin, and Dubinin models was followed, and the Dubinin isotherm model was the best-fitted model. the thermodynamic parameter ?G0 values at 20, 30, 40 and 50°C were (0.5163, -0.0691, -0.9589, -0.5927kJ/mol). The value of ?H0 and ?S0 were (12.713kJ/mol and 0.0422073kJ/mol.k) which indicated favorable and endothermic sorption. The presence and concentration of CIP in aqueous media were identified through UV analysis.
Oily wastewater is one of the most challenging streams to deal with especially if the oil exists in emulsified form. In this study, electrospinning method was used to prepare nanofiberous polyvinylidene fluoride (PVDF) membranes and study their performance in oil removal. Graphene particles were embedded in the electrospun PVDF membrane to enhance the efficiency of the membranes. The prepared membranes were characterized using a scanning electron microscopy (SEM) to verify the graphene stabilization on the surface of the membrane homogeneously; while FTIR was used to detect the functional groups on the membrane surface. The membrane wettability was assessed by measuring the contact angle. The PVDF and PVDF / Graphene membranes efficiency
... Show MoreThe research aims to determine the role of the practices of green human resources management in achieving requirements of environmental citizenship in the workplace, the General Company for Vegetable Oils was chosen for the application of field-side of research which represent one of the important industrial companies in Iraq, which suffers from poor Green human resources management applications, which reflected negatively on the development Environmental citizenship among Employees. The questionnaire use as a tool to collect data and information as well as field presence of the researcher, The research sample included (30) managers of departments and Division ,and through using statistical program (SPSS) the data has been analys
... Show MoreEnvironmental risk growing Become challenge "and a matter of controversy and concern to many of those concerned with environment, social, economic, and the same happens with the administrative rather than in isolation for this movement, as the issues of climate change Disturbed and troubled him, especially after what caused the risk of destruction, and irresponsibility , chaos, and the futility of resources, crops, fields, nature and homes and reactors, and after what happened in Japan from the scourge of "Hurricane tsunami " and earthquakes successive accompanied him and what became of him by surprise catastrophic affected the economy and the univ
... Show MoreAn Indirect simple sensitive and applicable spectrofluorometric method has been developed for the determination of Cefotaxime Sodium (CEF), ciprofloxacin Hydrochloride (CIP) and Famotidine (FAM) using reaction system bromate-bromide and acriflavine (AF) as fluorescent dye. The method is based on the oxidation of drugs with known excess bromate-bromide mixture in acidic medium and subsequent determination of unreacted oxidant by quenching fluorescence of AF. Fluorescence intensity of residual AF was measured at 528 nm after excitation at 402 nm. The fluorescence-concentration plots were rectilinear over the ranges 0.1-3.0, 0.05-2.6 and 0.1-3.8 µg ml-1 with lower detection limits of 0.013, 0.018 and 0.021 µg ml-1 an
... Show More

