Background: disturbed physiological rhythm of blood pressure in preeclampsia is a common finding. The role of oxidative stress in pathogenesis of preeclampsia is well accepted. Melatonin is a powerful free radical scavenger so it's rapidly consumed by enhanced reactive oxygen species in preeclampsia causing non-dipping in blood pressure.Objective: To evaluate the change in plasma melatonin levels in patients with preeclampsia and its relationship with blood pressure.Patients and methods: In this prospective case control study a total of 40 primigravidae pregnant women were recruited during the period of 11 months between August 2015 and August 2016 in Baghdad teaching hospital, medical city, Iraq, divided into two groups:First groups: (cases group) were 20 primigravidae pregnant women with PE.Second group: (control group) were 20 normal healthy primigravidae.Blood Pressure measurement, melatonin blood samples were taken, plasma melatonin levels measurement was done by ELISA immunoassay. Urine was collected over 24 hours for protein in urine measurement.Results : Plasma Melatonin level in control , day and night was (22.72 ± 2.6 pg/mL ) , (75.26 ± 2.99 pg/mL ) compared to Plasma Melatonin level in dipper PE day and night (20.5±2.4 pg/mL ) , (75.26 ± 1.8 pg/mL) which was statistically not significant( P value 0.055 ) , (P value 1.0) respectively .Plasma Melatonin level for non-dipper ( 22.45 ± 2.48 pg/mL) were similar to dipper (20.5±2.4 pg/mL) which is not significant (P value 0.1) , while Night time Plasma Melatonin of non-dipper (36.76 ± 1.27 ) were reduced when compared to control (75.26 ± 2.99 pg/mL) and to dipper group (75.26 ± 1.8 pg/mL ) which was highly significant (p <0.0001 , p <0.0001) respectively .Conclusion: Night time Plasma Melatonin level reduced in Primigravid Women with preeclampsia that did not show nocturnal dipping in blood pressure.
In this study, the CR-39 detector technique was used, to estimate the uranium concentration from the soil in midland refineries Company (Doura refine (, Baghdad, Iraq. Uranium concentrations in soil samples have been measured using solid state nuclear track detector type CR-39. Nine soil samples were collected from different areas within the Doura refinery and other soil samples were collected form Abu Tayara Street and ALshortaa District outside the refinery for comparison. The results showed variable values for uranium concentrations. The average value of uranium concentration was found to be 0.37 ppm in doura refinery. For areas outside the refinery, the concentration of uranium was 0.008 ppm. Thes
... Show MoreIn this study, a factorial experiment was conducted using a Randomized Complete Block Design (RCBD) with three replicates to investigate the effects of silicon at four concentrations: 0, 2, 4, and 6 ml/L, designated as S0, S1, S2, and S3, respectively and a calcium-boron combination at three concentrations: 0, (0.5 g/L Ca-EDTA, + 10 mg/L B), and (1 g/L Ca-EDTA, + 20 mg/L B), designated as C0, C1, and C2, respectively. on the activity of antioxidant enzymes and some qualitative traits of fruits. The results indicated that the studied traits were significantly influenced by the factors. Silicon application notably increased enzyme activity, treatment S3 showed the highest activity levels for peroxidase (POD) and superoxide dismutase (SOD) rea
... Show MoreThe aimes of this study is to investigate Optimism and Pessimism among university undergraduates including the first and fourth stage students ,the sample of this stoudy contained (326) students ,(166) male and (160) female, The researcher adopted a scale of Dember et al (1889) translated and adjusted to arabic version by Al-Dosoke (2001). The results have shown that students have optimism including the first and fourth stage and no significant difference between the students as far as ncluding the first and fourth study stage and gender, Implications of the results and recommendations for further research are discussed.
In this paper, we investigate the basic characteristics of "magnetron sputtering plasma" using the target V2O5. The "magnetron sputtering plasma" is produced using "radio frequency (RF)" power supply and Argon gas. The intensity of the light emission from atoms and radicals in the plasma measured by using "optical emission spectrophotometer", and the appeared peaks in all patterns match the standard lines from NIST database and employed are to estimate the plasma parameters, of computes electron temperature and the electrons density. The characteristics of V2O5 sputtering plasma at multiple discharge provisos are studied at the "radio frequency" (RF) power ranging from 75 - 150 Wat
... Show MoreBackground: Ultrasonography has been used to examine the thickness of the lower uterine segment in women with previous cesarean sections in an attempt to predict the risk of scar dehiscence during subsequent pregnancy. The predictive value of such measurement has not been adequately assessed. Objectives: To correlate lower uterine segment thickness measured by trans abdominal ultrasound in pregnant women with previous cesarean section with that measured during cesarean section by caliper and to find out minimum lower uterine segment thickness indicative of integrity of the scar.Methods: A prospective observational study at Elwyia Maternity Teaching Hospital, from January 2011 to January 2012. A total of 143 women were enrolled in the stu
... Show MoreBackground: Neural tube defects (NTDs) are said to be inherited in a multifactorial fashion, i.e. genetic-environmental interaction. Maternal nutritional deficiencies had long been reported to cause NTDs, especially folate deficiency during early pregnancy. More attention had been paid to the exact mechanism by which this deficiency state causes these defects in the developing embryo. The most significant of all researches was that connecting reduced folate and increased homocysteine level in maternal serum on one hand and the risk of developing a NTD baby on the other hand. Objectives : to determine the significance of homocysteine level in Iraqi mothers who gave birth to babies with NTDs as compared to normal controls. Patients, Materials
... Show MorePotentially inappropriate prescribing is the prescribing of a medication that may cause more harm than benefit, the elderly population aged 65 years or older is more prone to potentially inappropriate prescribing because of alterations in their physiology, pharmacokinetics, and pharmacodynamics as well as polypharmacy and comorbidities, Beers list is a screening tool that help doctors to detect potentially inappropriate prescribing in geriatric patients and is designed to solve this problem, the aim of this study is to measure the prevalence of potentially inappropriate prescribing among psychiatric patients using the Beers criteria as an assessment tool and find the relationship between duration of hospitalization, comorbidities and pol
... Show MoreA number of pulsed experiments have been carried out using a high-voltage circuit containing R,L, and C in certain arrangements. A spherical spark gap of steel electrodes was used as a high-current switch operated by a voltage of up to 8kV and triggered in both self-triggering and third-electrode triggering modes. Current measurements were carried out by using both current-viewing resistor and Rogowski coils designed for this purpose. Typical current waveforms have shown obvious dominating inductance effect of the circuit components in an underdamped oscillation. The behavior of the circuit impedance was studied by recording both pulsed current peaks and the charging voltages when currents of up to 2.5kA were recorded. The dur
... Show MoreThis paper aims to study the fractional differential systems arising in warm plasma, which exhibits traveling wave-type solutions. Time-fractional Korteweg-De Vries (KdV) and time-fractional Kawahara equations are used to analyze cold collision-free plasma, which exhibits magnet-acoustic waves and shock wave formation respectively. The decomposition method is used to solve the proposed equations. Also, the convergence and uniqueness of the obtained solution are discussed. To illuminate the effectiveness of the presented method, the solutions of these equations are obtained and compared with the exact solution. Furthermore, solutions are obtained for different values of time-fractional order and represented graphically.
Numerical simulation of charge density produced in plasma actuators is dependent upon the development of models dealing with electrical properties. The main aim of this work is to investigate the characteristics surface charge density and space charge density of DBD plasma actuator. A simple design of surface dielectric barrier discharge plasma actuator is used in the study. The discharge gas was N2:H2 mixture with applied voltage equal to 1.5 kV. A theoretical plasma model is used to establish the charge density details. Results show that surface charge density increased in value and spread in width alone the exposed electrode as the voltage increased and reached to the amplitude value.