Background: disturbed physiological rhythm of blood pressure in preeclampsia is a common finding. The role of oxidative stress in pathogenesis of preeclampsia is well accepted. Melatonin is a powerful free radical scavenger so it's rapidly consumed by enhanced reactive oxygen species in preeclampsia causing non-dipping in blood pressure.Objective: To evaluate the change in plasma melatonin levels in patients with preeclampsia and its relationship with blood pressure.Patients and methods: In this prospective case control study a total of 40 primigravidae pregnant women were recruited during the period of 11 months between August 2015 and August 2016 in Baghdad teaching hospital, medical city, Iraq, divided into two groups:First groups: (cases group) were 20 primigravidae pregnant women with PE.Second group: (control group) were 20 normal healthy primigravidae.Blood Pressure measurement, melatonin blood samples were taken, plasma melatonin levels measurement was done by ELISA immunoassay. Urine was collected over 24 hours for protein in urine measurement.Results : Plasma Melatonin level in control , day and night was (22.72 ± 2.6 pg/mL ) , (75.26 ± 2.99 pg/mL ) compared to Plasma Melatonin level in dipper PE day and night (20.5±2.4 pg/mL ) , (75.26 ± 1.8 pg/mL) which was statistically not significant( P value 0.055 ) , (P value 1.0) respectively .Plasma Melatonin level for non-dipper ( 22.45 ± 2.48 pg/mL) were similar to dipper (20.5±2.4 pg/mL) which is not significant (P value 0.1) , while Night time Plasma Melatonin of non-dipper (36.76 ± 1.27 ) were reduced when compared to control (75.26 ± 2.99 pg/mL) and to dipper group (75.26 ± 1.8 pg/mL ) which was highly significant (p <0.0001 , p <0.0001) respectively .Conclusion: Night time Plasma Melatonin level reduced in Primigravid Women with preeclampsia that did not show nocturnal dipping in blood pressure.
In this study, method for experimentally determining the electron density (ne) and the electron temperature (Te) in the atmospheric Argon plasma jet is used; it is based on optical emission spectroscopy (OES). Boltzmann plot method used to calculate these parameters measured for different values of gas flow rate. The results show that the electron temperature decreasing with the increase of gas flow rate also indicates an increasing in the electron density of plasma jet with increasing of gas flow rate.
Non thermal argon plasma needle at atmospheric pressure was generated. The experimental set up is based on very simple and low cost electric components that generate electrical field sufficiently high at the electrodes to ionize various gases, which flow at atmospheric pressure. The high d.c power supply is 7.5kV peak to peak, the frequency of the electrical field is 28kHz, and the plasma power less than 15W. The plasma is generated using only one electrode. In the present work the voltage and current discharge waveform are measured. Also the temperature of the working Ar gas at different gas flow and distances from the plasma electrode tip was recorded
Background:Parkinson’disease(PD) is a neurodegenerative disorder of the central nervous system characterized by resting tremor, bradykinesia, cogwheel rigidity, and impairment of postural reflexes; the frequency of PD increases with aging.Clinically Parkinson's disease characterized by two groups of symptoms: motor and non-motor symptoms.Non-motor symptoms can be categorized as autonomic, cognitive/psychiatric (may include depression, dementia, anxiety, hallucinations), sensory and rapid eye movements (REM) sleep behavior disorder (RBD).
Objectives:The objectives of this study are to find out the frequency of the non-motor symptoms of idiopathic Parkinson disease in a group of patients in Baghd
... Show MoreObjective:
This study aims to asses the patients' compliance with essential hypertension in respect to antihypertensive
medications, follow-up, dietary pattern and health habits, to identify the associated long-term complications, and
to find out the relationship between patient's compliance, and demographic characteristics such as age, gender,
level of education, and duration of disease.
Methodology:
A descriptive study was carried out in Nasiriyah Teaching Hospital to achieve presented objectives .
Results:
The results of the study revealed that there were a significant association between educational level and total
patient's compliance, a significant association was found between the duration of disease and
Objective:
This study aims to asses the patients' compliance with essential hypertension in respect to antihypertensive
medications, follow-up, dietary pattern and health habits, to identify the associated long-term complications, and
to find out the relationship between patient's compliance, and demographic characteristics such as age, gender,
level of education, and duration of disease.
Methodology:
A descriptive study was carried out in Nasiriyah Teaching Hospital to achieve presented objectives .
Results:
The results of the study revealed that there were a significant association between educational level and total
patient's compliance, a significant association was found between the duration of disease and
Objective: Assessment the psychological problems in patients with colorectal cancer, and to find out the
relationship between socio-demographic characteristics such as (age, sex, marital status, educational level,
and occupation) and psychological problems for those patients.
Methodology: A descriptive design is employed through the present study from 1
st July 2011 to 25
th December
2011 in order to study the quality of life in colorectal cancer patients with psychological problems.
A purposive (non probability) sample is selected for the study which includes (60) patients diagnosed with
colorectal cancer were treated in Mosul Oncology and Nuclear Medicine hospital or the patients who visited
the outpatient cl
In the present work, the effect of size of zinc dust particles on
AC argon discharge characteristics are investigated
experimentally. The plasma characteristics are determined by
using optical emission spectroscopy (OES) techniques. The
results illustrated that the electron temperature (Te) in the present
and absent of Zinc dust particle is reduced with increasing of
pressure. The electron temperature decreases with increasing of
Zinc dust size. Excitation temperature Tex is reduces with
increasing of Ar pressure in present and absent of zinc dust
particles. The present of Zinc dust reduce the Tex of Ar in both
Zinc dust size. The electron density increasing in the present and
absent of both zinc dust siz
The effect of Al dust particles on glow discharge regions, discharge
voltage, discharge current, plasma potential, floating potential,
electron density and electron temperature in planar magnetron
sputtering device has been studied experimentally. Four cylindrical
Langmuir probes were employed to measure plasma parameters at
different point on the radial axis of plasma column. The results
shows the present of Al dust causes to increase the discharge voltage
and reduce the discharge current. There are two electron groups in
the present and absent of Al dust particles. The radial profiles of
plasma parameters in the present of dust are non- uniform. The
floating potential of probe becomes more negatively while
Background: planter fasciitis is a common condition
seen in adults and sport men, it is characterized by dull
pain in the heel, especially when getting up and
standing on the foot in the morning or after sitting for a
long time.
Recently low level laser therapy is used as a method of
treatment.
Objective: to evaluate the benefit of laser therapy in
treatment of planter fasciitis.
Methods: Out of twenty five patients with planter
fasciitis exposed to laser therapy. Laser used is (diode
type) given in two cessions per week for four weeks,
time for each cession is about (12 minutes).
Results: complete recovery seen in (32%) of patients,
moderate improvement in (16%), mild improvement in
(24%), no