Dental casts come into direct contact with impression materials and other items that are contaminated by saliva and blood from a patient's mouth, leaving the casts susceptible to cross-contamination. The disinfectant solutions of the impression materials cause various adverse reactions. Therefore, disinfection of dental casts may be effective in preventing cross infection. This study was carried out to evaluate the surface hardness, dimensional accuracy, reproduction of details and surface porosity of type III, type IV and type IV extra hard dental stone after immersion in and spray by using SOLO and Sodium hypochlorite disinfectant solutions. Materials and methods: 240 Stone samples were prepared in rubber rings, A total of 60 test block were prepared for each test (surface hardness, dimensional accuracy, reproduction of details and surface porosity).the samples were divided into three groups (20 for each type of stone) type (III, IV, IV extra hard); SOLO and Sodium hypochlorite disinfectant by 2 methods (immersion and spray) were used in each test. Results: the results of dimensional accuracy, reproduction of details, surface hardness and surface porosity revealed no significant difference for all types of tested stone samples after immersion or spraying in SOLO and NaOCl except the surface hardness of type IV extra hard showed significant difference after spray with SOLO and the surface porosity of type IV extra hard showed significant difference after immersed in both SOLO and NaOCl solutions. Conclusions: Based on the results of this study immersion in and spray by using SOLO and NaOCl disinfectant solutions produced no adverse effect on dimensional accuracy, reproduction of details, surface hardness and surface porosity for type III, type IV dental stone and for type IV extra hard dental stone except for the surface hardness for type IV extra hard when sprayed with SOLO and the surface porosity when type IV extra hard stone immersed in the SOLO and NaOCl solutions.
A microbial study conducted for a number of flour samples (30 samples) Uses in the bakery ovens in various areas of the city of Baghdad, by used the conventional methods used in laboratories in microbial tests and compared with the modern techniqueby usedof BacTrac Device 3400 equipped from SY-LAB Impedance analysersAustrian company.The results of two ways showed (The conventional way and BacTrac Device test)that the total counts of aerobic bacteria, coliform bacteria, StaphylococcusSpp. bacteria, Bacillus cereus bacteria and yeasts and molds,Most of them were within the permissible borders in the Iraqi standard for grain and its products With free samples from SalmonellaSpp. bacteria, and that the screening by BacTrac device are shorten
... Show MoreThis present study is aimed at deciding the impact of exercises adapted to the ranges of movements of the arm on the performance of javelin throwing. As long as javelin throwing is quite a complex athletic event that presupposes a considerable amount of strength, speed, and biomechanical accuracy, it is crucial to learn whether the exercises designed to target the peculiarities of arm movements can have a positive effect on the performance of javelin throwers. To the study, experimental research with a single group of six youth javelin throwers was carried out. Before and after the eight-week training program, the pre-tests and post-tests were conducted to find the results of training with a specific focus on resistance exercises. Significa
... Show MoreForty eight isolates (41.02%) were obtained from 117 wound and burn samples. The isolates that showed high resistance for both antibiotic was two only that represent 4,1% from all isolates. The result of PCR product electrophoresis was referred that the gene is VIM gene. Lactose and raffinose showed double increasing in diameter of inhibition zone of imipenem with 1% that mean showed highest susceptibility that decreased with the concentration increasing, the same result were with meropenem. But no effect were detected on meropenem inhibition zone diameter. Mannose have no effect on the resistance in 1%, 3% and 7%. Results showed that only three case that increase the expression of gene, they were lactose at 1% concentration that increased
... Show MoreFilms of silver oxide of different thickness have been prepared by the chemical spray paralysis. Transmission and absorption spectra have recorded in order to study the effect of increasing thickness on some optical parameter such as reflectance, refractive index , and dielectric constant in its two parts . This study reveals that all these paramters affect by increasing the thickness .
The aim of the research is to design a test with cognitive achievement through the use of the inverted class strategy for some basic soccer skills for gyms for first-average students, within the curriculum of the Ministry of Education, where the researcher used the experimental approach. For the same division (B) and the number of each group (10) students, i.e. the total total of the research sample (20) students, and the pre-test for the research sample was applied through the design of the test prepared by the research after which the educational program with the strategy was applied to the research sample and continued (8) weeks after Completion of the tutorial has been post-tested for the research sample, In it, he reached significant r
... Show MoreIn this work, ZnS thin films have been deposited by developed laser deposition technique on glass substrates at room temperature. After deposition process, the films were annealed at different temperatures (200ºC , 300 ºC and 400ºC ) using thermal furnace.The developed technique was used to obtain homogeneous thin films of ZnS depending on vaporization of this semiconductor material by continuous CO2 laser with a simple fan to ensure obtaining homogeneous films. ZnS thin films were annealed at temperature 200ºC, 300 ºC and 400ºC for (20) minute in vacuum environment. Optical properties of ZnS thin film such as absorbance, transmittance, reflectance, optical band gap, refractive index extinction coefficient and absorption coefficien
... Show MoreSpray pyrolysis technique was subjected to synthesized (SnO2)1-x (TiO2: CuO) x Thin films on different substrates like glass and single crystal silicon using. The structure of the deposited films was studied using x-ray diffraction. A more pronounced diffraction peaks of SnO2 while no peaks of (CuO , TiO2 ) phase appear in the X-ray profiles by increasing of the content of (TiO2 , CuO) in the sprayed films. Mixing concentration (TiO2 , CuO) influences on the size of the crystallites of the SnO2 films ,the size of crystallites of the spray paralyzed oxide films change in regular manner by increasing of (TiO
... Show MoreHigh temperature superconductors materials with composition Bi1.6-xSbxPb0.4Sr2Ca2-yCdyCu3OZ (x = 0, 0.1, 0.2 and 0.3) and (y = 0.01 and 0.02), were prepared by using the chemical reaction in solid-state ways, and test influence of partial replacement of Bi and Ca with Sb and Cd respectively on the superconducting properties, all samples were sintered at the same temperature (850 oC) and for the same time (195 h). The structural analysis of the prepared samples was carried out using X-ray diffraction (XRD) measurements performed at room temperature, scanning electron microscope (SEM) and dc electrical resistivity was measured as a function of temperature. It was found that the sample prepared by partial substitution of Sb at ratio (x= 0.2
... Show MoreIn this work; copper oxide films (CuO) were fabricated by PLD. The films were analyzed by UV-VIS absorption spectra and their thickness by using profilometer. Pulsed Nd:YAG laser was used for prepared CuO thin films under O2 gas environment with varying both pulse energy and annealing temperature. The optical properties of as-grown film such as optical transmittance spectrum, refractive index and energy gap has been measured experimentally and the effects of laser pulse energy and annealing temperature on it were studied. An inverse relationship between energy gap and both annealing temperature and pulse energy was observed.