Objective: The aim of this study was to compare the marginal microleakage between bulk-fill, preheated bulk-fill, and bulk-fill flowable composite resins above and below cemento-enamel junction (CEJ) using micro-computed tomography. Methods: Sixty freshly extracted premolar teeth were prepared with a slot shaped cavities of a total of 120 Class II: 3mm (bucco-lingual), 2mm (mesio-distal) with mesial-gingival margin located 1mm coronal to CEJ, and distal gingival margin located 1mm apical to the CEJ. The samples were randomly divided into two main groups according to the restorative material (Tetric EvoCeram and 3M Filtek), and each group was further sub-divided into three subgroups according to the consistency (bulk fill, preheated bulk fill, and bulk fill flowable). The specimens were thermocycled (500 cycles,5–55 °C, 30 seconds dwell time) and immersed in a 50% ammonical silver nitrate for 24 hours. Microleakage was evaluated using micro-CT. Data analyzed via three-way ANOVA and random forest model (a machine learning algorithm). Results: There was no statistically significant three-way interaction between type of composite, location of gingival margin related to CEJ, and filling technique (P=0.103). However, the random forest model (a machine learning algorithm) showed type of composite is the most influential factor. Conclusion: Within the limitations of this study, considering the importance of the type of composite, the teeth restored with preheated bulk fill composite showed decrease in microleakage in comparison with bulk fill flowable composite
Since more than a decade, human rights dialogue in the European Mediterranean Region has been marked by a number of tensions. Although a number of factors contribute to such disputes, the effect of human rights conditionality, which ties EU economic cooperation progression with partner countries human rights advancement, on the dialogue has not been studied. Understanding the aspects, impacts, and effects of conditionality on Euro-Med relations is crucial for furthering dialogue. Yet this variable has been almost entirely neglected in academic and policy research. The research concludes several direct and indirect impacts of conditionality on human rights dialogue using a mixed methodology approach. Direct effects are reflected in the wi
... Show MoreThe way artists deal with body in their artistic works has had so many forms and methods, whether as an object for their drawings or as a material to create live artistic performances that relate to the idea of correspondence and interaction between different artistic categories such as: drama, dance, and painting as it is the case of the artist Marina Abramovic who has always used her body as an artistic unit to generate meaning and to perform her lively shows.
To go deeper into her career, our work was divided into 3 sections:
The first section was devoted to follow the main artistic stages that her body had gone through, starting with paintings she performed using concepts based on acting, simulation and nudity and ending wi
The artificial intelligence techniques such as neural networks and fuzzy systems play an important role to disconnect flexion & expansion of the swing leg, the earth response force of the other foot has been redesigned. Under that paper, we think the fuzzy controller plan issue for yield following flawed genuine investigation of nonlinear systems. For examination, an essential fuzzy control plot has been bristly developed dependent on a current methodology delegate under the field. In this paper, the Feedforward Neural Network has been implemented with integer, fixed point and floating point data representations. Additionally, The Fuzzy Logic Controllers in both analog and digital forms has been implemented in hardware. Both designs use les
... Show MoreThis valve is intended for use in valves for steering movement, using the qualities of the Magneto-rheological (MR) fluid to regulate the fluid, direct contact without the utilization of moving parts like a spool, a connection between electric flux, and fluid power was made, The simulation was done to employ the" finite element method of magnetism (FEMM)" to arrive at the best design. This software is used for magnetic resonance valve finite element analysis. The valve's best performance was obtained by using a closed directional control valve in the normal state normally closed (NC) MR valve, with simulation results revealing the optimum magnetic flux density in the absence of a current and the shedding condition, as well as the optimum
... Show MoreFlexible pavements are considered an essential element of transportation infrastructure. So, evaluations of flexible pavement performance are necessary for the proper management of transportation infrastructure. Pavement condition index (PCI) and international roughness index (IRI) are common indices applied to evaluate pavement surface conditions. However, the pavement condition surveys to calculate PCI are costly and time-consuming as compared to IRI. This article focuses on developing regression models that predict PCI from IRI. Eighty-three flexible pavement sections, with section length equal to 250 m, were selected in Al-Diwaniyah, Iraq, to develop PCI-IRI relationships. In terms of the quantity and severity of eac
... Show More|
In this work, an experimental investigation has been done for heat transfer by natural-convection through a horizontal concentric annulus with porous media effects. The porous structure in gap spacing consists of a glass balls and replaced by plastic (PVC) balls with different sizes. The outer surface of outer tube is isothermally cooled while the outer surface of inner tube is heated with constant heat flux condition. The inner tube is heated with different supplied electrical power levels. Four different radius ratios of annulus are used. The effects of porous media material, particles size and annulus radius ratio on heat dissipation in terms of average Nusselt number have been analyzed. |
Abstract: Reflection optical fibre Humidity sensor is presented in this work, which is based on no core fibre prepared by splicing a segment of no core fibre (NCF) at different lengths 1-6 cm with fixed diameter 125 µm and a single mode fibre (SMF). The range of humidity inside the chamber is controlled from 30% to 90% RH at temperature ~ 30 °С. The experimental result shows that the resonant wavelength dip shift decreases linearly with an increment of RH% and the sensitivity of the sensor increased linearly with an increasing in the length of NCF. However, a high sensitivity 716.07pm/RH% is obtained at length 5cm with good stability and reputability. Furthermore, the sensor is shif
... Show More