Preferred Language
Articles
/
Nha9SIcBVTCNdQwC-ULz
Is Orbital Floor Reconstruction With Titanium Mesh Safe?
...Show More Authors

Scopus Clarivate Crossref
View Publication
Publication Date
Sun Jan 01 2023
Journal Name
Journal Of Medicine And Life
Effect of commercially pure titanium implant coated with calcium carbonate and nanohydroxyapatite mixture on osseointegration
...Show More Authors

In this research, rabbit femurs were implanted with CP Ti screws coated with a combination of CaCO3 and nanohydroxyapatite, and the effect on osseointegration was assessed using histological and histomorphometric examination at 2 and 6 weeks. CaCO3 and nanohydroxyapatite were combined with the EPD to coat the surfaces of the CP Ti screws. The femurs of five male rabbits were implanted with coated and uncoated implant screws. Healing time was divided into two groups (2 and 6 weeks). After 2 and 6 weeks of implantation, the histological examination revealed an increase in the growth of bone cells for coated screws, and the histomorphometric analysis revealed an increase in the percentage of ne

... Show More
View Publication
Scopus (7)
Crossref (8)
Scopus Crossref
Publication Date
Sun Jun 10 2018
Journal Name
Annals Of Clinical And Analytical Medicine
Lead among children with autism in Iraq. Is it a potential factor?
...Show More Authors

Abstract Aim: Autism is a neurodevelopmental disorder which affects communication and social interaction of children. It is a heterogeneous disease with various clinical presentations. Some genes are involved in its pathogenesis. It has been suggested that environmental exposure to lead can increase the risk of autism. The aim of our study was to compare blood lead levels among autistic and non-autistic children. Material and Method: This retrospective study included 107 children (60 with autism and 47 without autism) referred from the different Iraqi provinces, in the years 2015, 2016 and 2017, to the poisoning consultation center in Baghdad. Data collection including age, gender, residence, referral source, family history and blood lead l

... Show More
View Publication Preview PDF
Crossref (2)
Clarivate Crossref
Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
A Comparative Study of Single-Constraint Routing in Wireless Mesh Networks Using Different Dynamic Programming Algorithms
...Show More Authors

Finding the shortest route in wireless mesh networks is an important aspect. Many techniques are used to solve this problem like dynamic programming, evolutionary algorithms, weighted-sum techniques, and others. In this paper, we use dynamic programming techniques to find the shortest path in wireless mesh networks due to their generality, reduction of complexity and facilitation of numerical computation, simplicity in incorporating constraints, and their onformity to the stochastic nature of some problems. The routing problem is a multi-objective optimization problem with some constraints such as path capacity and end-to-end delay. Single-constraint routing problems and solutions using Dijkstra, Bellman-Ford, and Floyd-Warshall algorith

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Jan 01 2014
Journal Name
Iraqi Journal Of Science
Calculate the Longitude and Orbital Motion for Amaletha, Europa, Ganymede and Callisto Satellites
...Show More Authors

The orbital motion and longitude for some Jupiter's satellites (Amaletha, Europa, Ganymede and Callisto) were calculated from two different locations Iraq and Syria. A program was designed, the input parameters were the desired year, month, day and the longitude of the location, the output parameters results were applied in form of a file, and this file includes the longitude, orbital motion, and local time of these satellites. A specific date 1-10-2013 was taken, the results of longitude was (20-336) º and orbital motion was (92-331) º for both Iraq and Syria location with observing time (05:24:14-15:18:10) for Iraq and (04:56:33-14:50:30) for Syria. The difference in time between the two locations was constant (00:45:00), these results

... Show More
Publication Date
Sun Apr 03 2016
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Nosocomial infections in a Surgical Floor of the General Ba’qubah Hospital; Iraq
...Show More Authors

Background: Prevention against nosocomial infection is an important issue of health care field and considered a challenge of patients’ since it reflects its effect on their quality of life. This due to that it will lead in most cases to prolonged hospitalization and also more cost.Objective: To determine the prevalence of different types of nosocomial infection and to demonstrate the association of different risk factors (hospital environment, workers, visitors) with nosocomial infection.Patients: this study was carried out in eleven months at Ba’quba general Hospital; Iraq. A total of 81 clinical specimens (urine, pus from abscess , burn swab, nasal swab, ear swab and wound swab) taken from surgical patients,102 specimens from

... Show More
View Publication
Crossref
Publication Date
Mon Nov 27 2023
Journal Name
Korean Journal Of Orthodontics
Effectiveness of laser-engineered copper-nickel titanium versus superelastic nickel-titanium aligning archwires: A randomized clinical trial
...Show More Authors

View Publication
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Sun Dec 01 2019
Journal Name
Baghdad Science Journal
Primary Colors Red, Yellow, and Blue Use as Self-Cleaning Paints with Layer of Titanium Dioxide
...Show More Authors

Transparent nano- coating was prepared by Sol-Gel method from titanium dioxide TiO2 which has the ability to self-cleaning coating used for hospitals, laboratories, and places requiring permanent sterilization. Three primary colors are selected (red, blue, and yellow) as preliminary study to the effect of these colors on the nano-coating. Three traditional oil paints color were used as base, then coated by a layer of TiO2-Sol and deposited on the paints. The optical properties of TiO2-Sol were measured; the maximum absorption wavelength at (λmax=387 nm), the refractive index (n=1.4423) and the energy band gap (Eg=3.2 eV). The structure properties found by X-ray diffraction of TiO

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Thu Sep 25 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Histological and histomorphometric analysis of strontium chloride coated commercially pure titanium implant compared with hydroxyapatite coating
...Show More Authors

Background: In recent years, the immediate loading of dental implants has become more accepted as a standard protocol for the treatment of the edentulous area. Success in implant dentistry depends on several parameters that may improve phenomenon of osseointegration and new bone formation in close contact with the implant. The aim of study was to evaluate the effect of strontium chloride coating of screw shape commercially pure titanium dental implant osseointegration at bone - implant interface by histomorphometric analysis and compare with hydroxyapatite coating at 2 time periods (2 weeks and 6 weeks). Materials and methods: Electrophoretic Deposition Technique (EPD) was used to obtain a uniform coating layer on commercially pure titanium

... Show More
View Publication Preview PDF
Publication Date
Tue Feb 12 2019
Journal Name
International Journal Of Biosciences
Biomechanical and histological assessment of titanium dental implants coated with strontium substituted hydroxyapatite and fluorapatite mixture
...Show More Authors

Dental implants are considered a unique treatment alternative for the replacement of missing dentition. There is a strive for materials which increase bone formation in bone implant interface and improve osseointegration to offer immediate loading directly after placement with decreased time. The aim of the study was to assess the effect of nano strontium substituted hydroxyapatite and nano fluorapatite mixture coating of screw shaped commercially pure titanium at the bone implant interface by torque removal test and histological assessment in rabbit tibia. Commercially pure titanium was used to prepare 80 screws that were divided into machined surfaces (CpTi), coated with (SrHA), coated with (FA) and coated with mixture 50%SrHA + 50%FA (mi

... Show More
Preview PDF
Publication Date
Sat Jan 02 2016
Journal Name
Iraqi Postgraduate Medical Journal
Wallplasty Versus Non Wallplasty in Arthroscopically Assisted Anterior Cruciate Ligament Reconstruction
...Show More Authors

Abstract ABSTRACT:BACKGROUND: Anterior cruciate ligament reconstruction (ACLR) is one of the most commonly performed orthopedic procedures. Technical factors especially correct tunnel placement play major role in its success. However its failure rate is still high (10%), and impingement of the graft on the posterior cruciate ligament (PCL) and the medial wall of the lateral femoral condyle is an important cause of failure. Wallplasty is a technique used to prevent graft impingement, but there is no consensus on its routine use.OBJECTIVE:Is to compare between the postoperative knee functional outcome and stability of arthroscopic ACLR performed with wallplasty versus those performed without wallplasty.PATIENTS AND METHODS: A prospective exp

... Show More
Preview PDF