Preferred Language
Articles
/
NeaKZZwBmraWrQ4do0ka
Antimicrobial behavior of nanocoated orthodontic micro-implants: An in vitro study
...Show More Authors
OBJECTIVE:

The need to overcome the failure of orthodontic micro-implants which might reach to 30% has led to the development of different methods, one of which is nanoparticle deposition.

AIM OF STUDY:

To evaluate the anti-microbial efficiency of TiO2 and ZnO nanoparticles (NP) when used as a coating for orthodontic micro-implants.

METHODS:

Thirty titanium alloy micro-implants were used in the presented study. They were divided into three groups according to the coating method and the coating materials used: the control group without surface coating; the titanium dioxide (TiO2)-coated group, in which direct current (DC) spattering was used to coat the micro-implants with a TiO2 layer; and the TiO2 and zinc oxide (TiO2ZnO)-coated group, in which the micro-implants were coated with a TiO2 layer via direct current (DC) spattering and a zinc oxide (ZnO) layer via laser vacuum. The micro-implant surfaces were characterized using scanning electron microscopy (SEM) and an energy-dispersive spectrometer (EDS). The antibacterial susceptibility was assessed using gram-positive and gram-negative bacteria.

RESULTS:

SEM and EDS tests confirmed the coating of the micro-implants in the TiO2- and TiO2ZnO-coated groups. The micro-implants in the TiO2- and TiO2ZnO-coated groups demonstrated higher antibacterial ability than the control group.

CONCLUSION:

This study demonstrated the significance of improving the surface of orthodontic micro-implants by coating them with TiO2 and ZnO nanoparticles to improve osseointegration and prevent biofilm formation.

Scopus Crossref
View Publication
Publication Date
Mon Jan 01 2024
Journal Name
Baghdad Science Journal
Study of the Anticancer and Antimicrobial Biological Activity of a New Series of Thiohydantoin Derivatives
...Show More Authors

        Recently, some prostate cancer patients have acquired resistance to the second -generation drugs (anzalutamide and apalutamide) prescribed for the treatment of this disease due to the emergence of the F876L mutation, which represents a challenge to modern medicine. In this study, a new series of 2-thiohydantoin derivatives were prepared through the reaction of different derivatives of maleimide (1c-4c) with isothiocyanate derivatives. The prepared compounds were diagnosed using FT-IR,1H-NMR ,13C-NMR, Mass spectra. The prepared series compounds has been studied against prostate cancer cells. The MTT assay was used to determine the activity of the prepared compounds against prostate cancer cells. The da

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Crossref
Publication Date
Sun Apr 22 2018
Journal Name
Acs Biomaterials Science & Engineering
Engineered coatings for titanium implants to present ultra-low doses of BMP-7
...Show More Authors

The ongoing research to improve the clinical outcome of titanium implants has resulted in the implementation of multiple approaches to deliver osteogenic growth factors accelerating and sustaining osseointegration. Here we show the presentation of human bone morphogenetic protein 7 (BMP-7) adsorbed to titanium discs coated with poly(ethyl acrylate) (PEA). We have previously shown that PEA promotes fibronectin organization into nanonetworks exposing integrin- and growth-factor-binding domains, allowing a synergistic interaction at the integrin/growth factor receptor level. Here, titanium discs were coated with PEA and fibronectin and then decorated with ng/mL doses of BMP-7. Human mesenchymal stem cells were used to investigate cellular resp

... Show More
View Publication Preview PDF
Scopus (47)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Tue Mar 01 2022
Journal Name
Journal Of Osseointegration & Oral Rehablitation
Evaluation of marginal bone loss around SLActive implants by CBCT using different implant dimensions and surgical approaches: A clinical and radiological prospective study
...Show More Authors

Aim: The reduction in the amount of marginal bone is the most important demand for the long term success of dental implants. This prospective clinical study was aimed to investigate the marginal bone loss of early loaded SLActive implants with different dimensions and surgical approaches. Materials and methods Fifteen patients aged from 18 to 60 years were divided into 2 groups (flapped and flapless approach) that underwent delayed implant placement protocol with SLActive implants. The marginal bone level was estimated by cone-beam computed tomography during three different periods: preoperatively, 8 weeks after surgery and 24 weeks after loading of the prosthesis. Results: The mean value of marginal bone level was not significantly chan

... Show More
View Publication Preview PDF
Scopus (6)
Scopus
Publication Date
Sat Jan 02 2021
Journal Name
Kerbala Journal Of Pharmaceutical Sciences
Study the Effect of Disintegrant Types on Preparation and In-Vitro Evaluation of Salbutamol Sulfate Effervescent Granules
...Show More Authors

Publication Date
Wed Jul 15 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The influence of cavity design for cusp coverage on fracture strength of weakened maxillary first premolars using two esthetic restorative systems (CAD/CAM hybrid ceramic and nanohybrid composite) (An in vitro study)
...Show More Authors

Background: Maxillary first premolar with wide MOD cavity more susceptible to fracture. The aim of this study was to assess the influence of cavity design for cusp coverage on the fracture resistance of weakened maxillary first premolar restored with CAD/CAM hybrid ceramic versus nanohybide composite. Materials and Methods: Fifty six intact maxillary first premolars of approximately comparable sizes were divided into seven groups eight for each: Group A: Intact teeth (control group); Group B: teeth prepared for MOD inlay; Group C: teeth prepared for MOD onlay covering the lingual cusp; Group D: teeth prepared for MOD covering buccal and lingual cusps ,the previous three groups indirectly restored with nanohybrid composite (3M ESPE Z 250 X

... Show More
View Publication Preview PDF
Publication Date
Wed Sep 22 2021
Journal Name
International Journal Of Corrosion And Scale Inhibition
Role of vitamin C in the protection of the gum and implants in the human body: theoretical and experimental studies
...Show More Authors

The article describes a study on the role of vitamin C as a protective agent for the teeth, gum, and implants using quantum chemical calculations and polarization tests. The Density Functional Theory (DFT) at 6-311G (d, p) basis set is used to estimate the ability of vitamin C to inhibit the corrosion of the abovementioned parts. The experimental study was performed in a at human body media simulator (Hank’s balanced salt solution) at a temperature of 37°C. The compound was optimized for its ground state, physical properties, and corrosion parameters. Further, HOMO, LUMO, energy gap, dipole moment, and other parameters were used to predict the inhibitor’s efficiency. Gaussian 09, UCA-FUKUI, MGL tools, DSV, and LigPlus software was used

... Show More
View Publication
Scopus (36)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Wed Oct 01 2025
Journal Name
Civil Engineering Journal
Study on Shear Behavior of Reinforced Concrete Beams Confined with Reinforcing Meshes
...Show More Authors

This study reveals the results of a numerical simulation performed using the ABAQUS/CAE finite element program. The study aimed to provide a simulation model that can forecast the shear behavior of reinforced concrete beams confined with reinforcing meshes. Limited numerical studies have been conducted using geogrid or FRP mesh as shear reinforcement, with limited representation accuracy and limited material quality. The results were compared to published experimental findings in the literature. The finding of the finite element model and the experimental results were highly comparable; consequently, the model was determined to be valid. Following this, the domain of numerical analyses was broadened to include the investigation of m

... Show More
View Publication
Scopus Crossref
Publication Date
Mon Jan 01 2018
Journal Name
Aip Conference Proceedings
The study of behavior titanium pure commercially coated with hydroxyapatite and zirconia
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Journal Of Engineering
The Behavior of the Al-Kadhim Minaret during Earthquakes: A Virtual Study
...Show More Authors

The study focuses on the causes of minaret tilting as well as possible solutions. The major aims of this study are to improve knowledge of historical tall structure stability and rehabilitation operations using the finite element approach to model the soil and minaret (PLAXIS 3D 2020), a platform for computational soil investigation and modeling. The numerical analysis aims to identify stresses, settlement, and deformation of the soil and minaret in various scenarios like Earthquakes, explosions, and winds. The simulation of the problem by the PLAXIS 3D revealed that the greatest lateral displacement computed at the Top Minaret is 5.5 cm, and the greatest vertical movement is calculated to be 3 cm. Seismic settlement is the effect of ear

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Dec 01 2015
Journal Name
Journal Of Engineering
Study the Dynamic Behavior of Rotor Supported on a Worn Journal Bearings
...Show More Authors

In this paper, the effect of wear in the fluid film journal bearings on the dynamic behavior of rotor bearing system has been studied depending on the analytical driven of dynamic stiffness and damping coefficients of worn journal bearing. The finite element method was used to modeling rotor bearing system. The unbalance response, critical speed and natural frequency of rotor bearing system have been studied to determine the changes in these parameters due to wear. MATLAB software was used to find the analytical values of dynamic coefficients of journal bearing. The results of rotor mounted on fluid film journal bearings showed that the wear in journal bearing increases the amplitude of unbalance response and decrease critical speed, sta

... Show More
View Publication Preview PDF