A novel metal-organic framework (MOF) sorbent based on tannic acid/copper (TA/Cu) was synthesized and characterized for the application of the anticancer drug imatinib (IMA) from biological samples. The TA/Cu MOF was prepared via a facile coordination reaction and thoroughly characterized by SEM, XRD, and FTIR techniques. Critical parameters influencing the extraction efficiency of imatinib mesylate (IMAM), including pH, ionic strength, desorption solvent, and adsorption-desorption time were optimized. With acetonitrile as the desorption solvent, the method demonstrated a broad linear range of 0.55-300 μg L-1 under ideal conditions. Limits of detection and quantification were found to be 0.16 μg L-1 and 0.55 μg L-1, respectively. For plasma samples spiked at clinically relevant concentrations (5, 20, and 50 μg L-1), the sorbent showed good reusability over four cycles and negligible matrix effects. In comparison to previously published methods, the developed dispersive solid phase extraction method based on TA/Cu MOF performed better in terms of simplicity, enrichment factor, and analytical figures. Another objective of this study was to develop a liquid chromatography with tandem mass spectrometry technique that could be commonly and readily used for therapeutic drug monitoring of imatinib following extraction by solid phase extraction (SPE). Therapeutic monitoring applications can reliably quantify IMA in complex biological matrices as a result of the fast dispersive solid phase extraction (DSPE) procedure and environmentally friendly sorbent. For citation: Russol Abdul Salam Faraj, Noor H.K., Saba H. Jamel, Jasim Jamur M.S. LC-MS/MS method for the determination of imatinib mesylate in blood plasma samples after adsorption by copper tannic acid. ChemChemTech [Izv. Vyssh. Uchebn. Zaved. Khim. Khim. Tekhnol.]. 2025. V. 68. N 3. P. 27-35. DOI: 10.6060/ivkkt.20256803.7121.
New membrane electrodes for determination of ciprofloxacin hydrochloride were prepared depending on ciprofloxacin hydrochloride - phosphotungstic acid (CFH-PT) as an active material and these electrodes were made with three plasticizers: Di-octylphenylphosphonate(DOPH), Di-butyl phosphate (DBP)Tri-n-butyl phosphate(TBP), in PVC matrix. One of the ciprofloxacin electrodes was gave Nernstian slope equal to 57.21 mV/ decade for DOPH membrane with concentration range from 1.5×10-5 to1.0×10-1 M, and detection limit equal to 1.5×10-6 M .Lifetime was 93 days. Non- Nernstian responses equal to 39.40 and 30.70 mV/ decade for membranes DBP, TBP, respectively. These electrodes were gave concentration range from 1.0× 10-5 to 1.0×10-2 and from 4.0
... Show MoreCadmium sulphide CdS films with 200 nm have been prepared by thermal evaporation technique on glass substrate at substrate room temperature under vacuum of 10-5mbar.In this paper, the effect of Dielectric Barrier Discharge plasma on the optical properties of the CdS film. The prepared films were exposed to different time intervals (0, 3, 5, 8) min. For every sample, the Absorption A, absorption coefficient α , energy gap Eg ,extinction coefficient K and dielectric constant ε were studied. It is found that the energy gap were decreased with exposure time, and absorption , Absorption coefficient, refractive index, extinction coefficient, dielectric constant increased with time of exposure to the plasma. Our study conside
... Show Morea simple accurate and sensitive spectrophotometric method for the determination of promethazine HCI has been developed the method is based on the oxidative coupling reaction of promethazine
Spectrophotometric methods were developed for the determination of rantidine-HCl in pharmaceutical tablets. These methods were based on the reaction of DDQ and p-chloranil with rantidine-HCl, resulting in the formation of an orange-red and purple colored products which are quantified spectrophotometrically at 460 and 540nm in DDQ and p-chloranil, respectively. A graph of absorbance versus concentration show that Beer’s law is obeyed in a concentration ranges of 20-160 and (30-120)g/ml with molar absorptivities of 2.631 x 103 and 1.052 x 103 The optimum conditions for color development are described and the proposed methods were applied satisfactory to pharmaceutical preparations
Pituitary adenomas are the anterior pituitary tumors. Patients with an Aryl Hydrocarbon Receptor-Interacting Protein (AIP) mutation (AIP- mut) tend to have more aggressive tumors occurring at a younger age. Single nucleotide polymorphisms (SNPs) in many studies have been related to metabolic comorbidities in the general population. Study aims investigated the role of AIP gene SNPs with susceptibility to acromegaly pituitary- adenoma, with levels of LH, FSH, TSH, Testosterone, IGF1,GH, FT4 , Prolactin hormones and blood sugar levels. The study was conducted on a group of acromegaly patients, including 50 patients) both Genders( with hyperplasia of the ends, and apparently healthy control group. Genotyping of
... Show MoreIn the present article, we implement the new iterative method proposed by Daftardar-Gejji and Jafari (NIM) [V. Daftardar-Gejji, H. Jafari, An iterative method for solving nonlinear functional equations, J. Math. Anal. Appl. 316 (2006) 753-763] to solve two problems; the first one is the problem of spread of a non-fatal disease in a population which is assumed to have constant size over the period of the epidemic, and the other one is the problem of the prey and predator. The results demonstrate that the method has many merits such as being derivative-free, overcome the difficulty arising in calculating Adomian polynomials to handle the nonlinear terms in Adomian Decomposition Method (ADM), does not require to calculate Lagrange multiplier a
... Show MoreA theoretical model is developed to determine time evolution of temperature at the surface of an opaque target placed in air for cases characterized by the formation of laser supported absorption waves (LSAW) plasmas. The model takes into account both plasma dynamics and time variation of incident laser pulse (i.e. pulse shape or profile).Shock tube relations were employed in formulating plasma dynamics over target surface. Gaussian function was chosen in formulating the pulse profile in the present modeling