Abstract Background Deep learning (DL) has attracted increasing attention in orthodontics, with many studies reporting high diagnostic and predictive accuracy. However, despite these promising results, routine clinical adoption remains limited. Objectives This scoping review aimed to explore the main barriers that restrict the translation of DL systems from research environments into everyday orthodontic practice. Methodology The review was conducted in accordance with PRISMA-ScR guidelines. Electronic searches were performed in PubMed, Scopus, Web of Science, and IEEE Xplore for English-language studies published between 2015 and June 2025. Studies reporting quantitative performance of DL-based orthodontic applications were included. Data were extracted using a standardized charting form and synthesized using a barrier-centered thematic approach. Results From 612 records, 26 studies were included. While most demonstrated high internal performance, consistent barriers to clinical implementation were identified. These primarily involved limited dataset diversity, single-center data sourcing, absence of external validation, and methodological heterogeneity. In addition, reliance on controlled research settings and insufficient real-world testing further restricted translation into routine orthodontic practice. Conclusion Although deep learning shows promising technical performance in orthodontics, meaningful clinical integration remains limited. Overcoming current barriers will require stronger validation standards, greater transparency, collaborative multicenter research, and implementation strategies that align with real clinical workflows.
This research aims to design a high-speed laser diode driver and photodetector, the result is the
design of the high-speed laser diode driver with a short pulse of 10 ns at 30 KHz frequency and the
delivered maximum pulse voltage is 5.5 mV. Also, its optical output power of the laser diode driver is
about 2.529 mW for the centroied wavelength 1546.7 nm with FWHM of 286 pm and (1270-1610) nm.
The design of the circuit based on bipolar transistor where the input pulse signal is simply generated by
an arduino kit with 15 kHz frequency and then compensated to trigger to small signal amplifier which
was is simply NPN C3355 transistor and the output is a current driver to the laser diode. OptiSystem
software and Electronic
This research include design and implementation of an Iraqi cities database using spatial data structure for storing data in two or more dimension called k-d tree .The proposed system should allow records to be inserted, deleted and searched by name or coordinate. All the programming of the proposed system written using Delphi ver. 7 and performed on personal computer (Intel core i3).
The construction project is a very complicated work by its nature and requires specialized knowledge to lead it to success. The construction project is complicated socially, technically and economically in its planning, management and implementation aspects due to the fact that it has many variables and multiple stakeholders in addition to being affected by the surrounding environment. Successful projects depend on three fundamental points which are cost-time, performance and specifications. The project stakeholder's objective to achieve best specifications and the cost-time frame stipulated in the contract.
The question is, was the optimum implementation accomplished? The provision for the success of the project
... Show MoreAlizarin is one of the popularly used and wide separated compounds with a chemical name (1,2- dihydroxy-9,10-anthraquinone) which belong to the anthraquinones family that contain three aromatic conjugated rings and in the central rings it contains two ketonic groups.1
Previous studies on the synthesis and characterization of metal chelates with uracil by elemental analysis, conductivity, IR, UV-Vis, NMR spectroscopy, and thermal analysis were covered in this review article. Reviewing these studies, we found that uracil can be coordinated through the electron pair on the N1, N3, O2, or O4 atoms. If the uracil was a mono-dentate ligand, it will be coordinated by one of the following atoms: N1, N3 or O2. But if the uracil was bi-dentate ligand, it will be coordinated by atoms N1 and O2, N3 and O2 or N3 and O4. However, when uracil forms complexes in the form of polymers, coordination occurs through the following atoms: N1 and N3 or N1 and O4.
The provision of safe water for people is a human right; historically, a major number of people depend on groundwater as a source of water for their needs, such as agricultural, industrial or human activities. Water resources have recently been affected by organic and/or inorganic contaminants as a result of population growth and increased anthropogenic activity, soil leaching and pollution. Water resource remediation has become a serious environmental concern, since it has a direct impact on many aspects of people’s lives. For decades, the pump-and-treat method has been considered the predominant treatment process for the remediation of contaminated groundwater with organic and inorganic contaminants. On the other side, this tech
... Show More