Introduction: Methadone hydrochloride (MDN) is an effective pharmacological substitution treatment for opioids dependence, adopted in different countries as methadone maintenance treatment (MMT) programmes. However, MDN can exacerbate the addiction problem if it is abused and injected intravenously, and the frequent visits to the MMT centres can reduce patient compliance. The overall aim of this study is to develop a novel extended-release capsule of MDN using the sol-gel silica (SGS) technique that has the potential to counteract medication-tampering techniques and associated health risks and reduce the frequent visits to MMT centres. Methods: For MDN recrystallisation, a closed container method (CCM) and hot-stage method (HSM) were conducted, and MDN crystals were characterised using the polarised light microscope (PLM). MDN crystal thickness was determined by scanning electron microscopy (SEM) and confocal microscopy (CM) to establish a relationship between MDN crystals thickness and their birefringence colours using the Michel-Levy Birefringence Colour Chart. The experimental series was continued to produce novel silica-based MDN formulations A and B capsules by adding MDN powder at the end and beginning of the SGS process, respectively. The silica-based MDN formulations were characterised by Fourier transform infrared (FT-IR), SEM, differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), PLM and mean grey value (MGV) analyses. The in vitro release studies (n=3) for the silica-based MDN formulations and pure MDN capsules were conducted in a phosphate buffer solution (pH= 7.2) for 7 days. Stability studies were conducted for 1 month by keeping the silica-based MDN capsules under 25°C and 57% RH. Results: The optimal method to produce large numbers of MDN crystals was the CCM, and MDN crystals were characterised as diamond shaped with an intrinsic angle of 62o. The SEM surpassed the CM in measuring MDN crystal thickness, and Mann-Whitney U Test showed statistically significant differences between SEM and confocal thickness measurements (U= 1283, p < 0.05) as the SEM exhibited thinner diamond crystals (6.62 ± 2.9 µm) than the CM measurements (9.6 ± 4.6µm). According to the Michel-Levey birefringence colour chart (using the SEM mean thickness of MDN crystals and their retardation value of 428 nm), most of MDN crystals demonstrated a yellow colour. The FT-IR, SEM, DSC, MGV and PLM analyses of both silica-based MDN formulations revealed that MDN was successfully incorporated inside the silica network producing amorphous material (with no appearance of the melting peak of pure MDN at 233.4°C) with evidence of no physical or chemical interaction between sol-gel silica and MDN. However, the TGA analysis revealed a significantly greater amount of MDN was loaded inside the silica-based MDN formulation B compared to A (t = 2.80, p = 0.009, n=6), as 28.3 ± 0.6 mg of MDN was loaded in the former while 25.6 ± 0.7 mg in the latter. In addition, the silica-based MDN formulation B released 10% more MDN after 7 days than formulation A, and both formulations were stable when stored for 1 month under 57% RH and 25°C. Conclusion: The novel combined use of SEM and PLM techniques shows a potential for the identification of MDN in forensic science as it established a range of birefringence colours of MDN crystals. Moreover, the new silica-based MDN formulation B can help to deter MDN abuse and increase patient adherence to MMT due to its potential to sustain MDN release and reduce the frequent visits to MDN treatment centres.
In study of effective bioactive compounds, we have synthesized the Co((ІІ), Mn(ІІ), Fe(ІІ), Cu(ІІ), Ni(ІІ), and Zn(ІІ) complexes of the Schiff base derived from trimethoprim and2'-amino-4-chlorobenzophenone and characterized by spectroscopic (NMR, IR, Mass, UV–vis,), analytical, TGA studies and magnetic data .The solution electronic spectral study suggests the stoichiometry of the synthesized complexes and Elemental analysis detected the square planer and octahedral geometry of the compounds. The prepared metal complexes presented promoted efficiency versus the screened bacterial (Escherichia Coli and Staphylococcus aureus) antibacterial efficacy against (Staphylococcus aureus, Salmonella spp., E. coli, Vibrio spp., Pseud
... Show MoreER Abbas, AA Jasim, Journal of Physical Education, 2023 - Cited by 1
The typical test for diagnosis of severe acute respiratory syndrome coronavirus 2 is a reverse transcription-polymerase chain reaction (RT-PCR) technique, but the chest CT scan might play a complementary role at the first detection of Coronavirus Disease 2019 (COVID-19) pneumonia. Objectives: To determine the sensitivity of CT scan on patients with COVID-19 in Al-Najaf, Iraq, and to compare the accuracy of CT scan with that of RT-PCR technique. Material and Method: This is a prospective study. The patients suspicious of having COVID-19 infection and respiratory symptoms were registered. All patients were diagnosed by RT-PCR and chest CT. Diagnostic performance of CT was intended using RT-PCR as the reference sta
... Show MoreAbstract
Objectives: To find out the association between enhancing learning needs and demographic characteristic of (gender, education level and age).
Methods: This study was conducted on purposive sample was selected to obtain representative and accurate data consisting of (90) patients who are in a peroid of recovering from myocardial infarction at Missan Center for Cardiac Diseases and Surgery, (10) patients were excluded for the pilot study, Data were analyzed using descriptive statistical data analysis approach of frequency, percentage, and analysis of variance (ANOVA).
Results: The study finding shows, there was sign
... Show MoreCommercial graphite (CGT) powder was used as an adsorbent surface for cationic dye, Janus green (JG), from aqueous solutions. This study aims to highlight the practical significance of using inexpensive CGT as an efficient adsorbent for the removal of JG dye from industrial wastewater. CGT was characterized by Fourier transform infrared spectroscopy, scanning electron microscopy, and X-ray diffraction. The adsorption process was investigated by examining parameters like the weight of the adsorbent, contact time, and temperature. Pseudo-second-order kinetic (PSO), pseudo-first-order, and intraparticle diffusion were used for analyzing the kinetic data. JG dye's adsorption kinetics fit the PSO kinetic model well (R2= 0.999). Furthermo
... Show MoreThe author addresses the issue of the linguoculturological component in the process of teaching Russian to Arabic students, focuses on the peculiarities of the national character of students. The author also refers to the long-standing ties of Russian and Arab cultures, thus emphasizing the relevance of this aspect for the current state and situation of the Russian language in Arab countries.
Автор статьи обращается к вопросу лингвокультурологической составляющей в процессе преподавания русского языка арабским студентам, останавливается на особенностях национального хара
... Show MoreA (k,n)-arc is a set of k points of PG(2,q) for some n, but not n + 1 of them, are collinear. A (k,n)-arc is complete if it is not contained in a (k + 1,n)-arc. In this paper we construct complete (kn,n)-arcs in PG(2,5), n = 2,3,4,5, by geometric method, with the related blocking sets and projective codes.
A new Schiff base (HL2) ligand (4‐{2‐[(2‐hydroxy‐benzylidene)‐amino]‐ethyl}‐benzene‐1,2‐diol) has been synthesized by condensing of 4‐(2‐amino‐ethyl)‐benzene‐1,2‐diol and 2‐hydroxy‐benzaldehyde. In turn, its transition metal complexes were prepared, having the following general formulas: Ni(L2)2, Pd(L2)2, and Pt(L2)22Cl. The prepared ligand and its metal complexes Ni(II), Pd(II), and Pt(IV) have been characterized by Fourier transform infrared (FTIR) spectra, proton nuclear magnetic resonance (1H‐NMR
In this work, electrochemical process was presented to polymerized eugenol on Gr.2 and Gr.5 titanium alloys before and after treated by Micro Arc Oxidation (MAO), where Gr.2 is commercial pure titanium and Gr.5 is Ti-6Al-4V dental alloys. The deposited layers were characterized by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FTIR). The adhesion strength of polymeric thin-film was estimation by using pull-off adhesion test and the result was the adhesion strength of PE was (1.23 MPa) on Gr.2 before MAO and increase to (1.98 MPa) on Gr.2 after MAO treatment. The corrosion behavior of Gr.2 and Gr.5 alloy in artificial saliva environment at
... Show More