Tight oil reservoirs have been a concerned of the oil industry due to their substantial influence on oil production. Due to their poor permeability, numerous problems are encountered while producing from tight reservoirs. Petrophysical and geomechanical rock properties are essential for understanding and assessing the fracability of reservoirs, especially tight reservoirs, to enhance permeability. In this study, Saadi B reservoir in Halfaya Iraqi oil field is considered as the main tight reservoir. Petrophysical and geomechanical properties have been estimated using full-set well logs for a vertical well that penetrates Saadi reservoir and validated with support of diagnostic fracture injection test data employing standard equations and correlations. Subsequently, breakdown pressures are computed, and two fracturing models have been developed. The petrophysical analysis infers that the reservoir has poor properties, while the findings of the geomechanical properties indicate that the reservoir is brittle with ductile rock strata. These ductile strata underlay and overlay more brittle formations than the reservoir. The results from diagnostic fracture injection test DFIT are quite consistent with well logs results. The breakdown pressure reflects that this reservoir could easily be fractured by inserting pressure equal to 6250 psi. However, the fracturing model design parameters manipulates the fracture height confinement within Saadi Formation and its propagation to Hartha and/or Tanuma Formations. Therefore, the employment of petrophysical and geomechanical properties of the rocks assists in understanding the fracability of the formation and demonstrating the orientation and the fracture propagation direction.
In this study the Entrance Surface Dose (ESD) received by pediatrics patients undergoing chest, abdomen and skull X-ray examinations was estimated. The study was conducted in two hospitals in Najaf city where three radiographic systems were considered. The study participants were classified into four age groups 0-1 , 1-5 , 5-10 and 10-15 years. Calculations were performed using exposure factors, kVp, mAs and focal-skin distance, together with patient data age. The ESD was calculated for the involved patients who underwent an Antero-posterior (AP) chest, abdomen and skull X-ray examination. The resulted data were analyzed and compared with international dose references. For all studied radiographic examinations and all X-ray mac
... Show MoreThis research aims to study and evaluate the reality of the Iraqi banks in terms of how they cope with the risks of the banking business, specifically banking operational risks, and to develop a model integrated to define, identify, measure and mitigate the impact of these risks on according to the Basel Committee requirements II about the dangers of Alchgal.uchir major search to the presence of weak results in the Iraqi banks in understanding and defining and measuring operational risks and not hedged properly, which avoids those banks operating losses as well as the results show there is a shortage in the equation of capital adequacy applied by the Iraqi banks because of non-observance of the minimum capital required to counter the ris
... Show More
Detection of virulence gene agglutinin-like sequence (ALS) 1 by using molecular technology from clinical samples (
In the mist of developments in the course of scientific research in general and humanities in particular and the accompanying changes in the visions and policies inspired by the need for these sciences to follow the qualitative methods in dealing with many of the topics or problems that require for their solution to obtain qualitative information which can be provided by resorting to quantitative research. Therefore, a new trend has emerged in many public relations› researchers who believe that qualitative research methods should be used by establishing scientific foundations and methodological classification based on the use of these methods and determining the nature of the subjects applied in them to reach results that are character
... Show MoreThe study aimed to establish the association of miR-153-3p expression with treatment response to IM in CML patients. Sixty CML patients were included and divided into two groups consistent with their response to treatment whether sensitive or resistant to IM. Ten healthy normal participants were enrolled as control group. RNA was extracted from serum to work out miR-153-3p expression utilizing real-time quantitative reverse transcription polymerase chain reaction. The primers were supplied by Macrogen Inc. Twenty seven patients were sensitive to imatinib and 33 were resistant to imatinib. The ratio of male to female was 1.14:1. The bulk (58%) of patients were within the age range of 41-60 years. Weight and gender did not significantly diffe
... Show MoreStick- slip is the continuous stopping& release of the Bit/BHA due to the irregular down-hole rotation prompted by the existing relationship between the friction torque and the torque applied from the surface to free the bit.
Friction coefficient between BHA and wellbore is the main player of stick slip amount, which can be mitigated by support a good lubricators as additives in drilling mud.
Mathematical (or empirical) solves should be done through adjusting all parameters which supposed to reduce stick- slip as low as possible using different models, one of the main parameters is drilling mud. As per Nanoparticles drilling fluid is a new technology that offers high performance
... Show MoreIn this paper, a miniaturized 2 × 2 electro-optic plasmonic Mach– Zehnder switch (MZS) based on metal–polymer–silicon hybrid waveguide is presented. Adiabatic tapers are designed to couple the light between the plasmonic phase shifter, implemented in each of the MZS arms, and the 3-dB input/output directional couplers. For 6 µm-long hybrid plasmonic waveguide supported by JRD1 polymer (r33= 390 pm/V), a π-phase shift voltage of 2 V is obtained. The switch is designed for 1550 nm operation wavelength using COMSOL software and characterizes by 2.3 dB insertion loss, 9.9 fJ/bit power consumption, and 640 GHz operation bandwidth