The bubbled slab, a type of reinforced concrete (RC) slab with plastic voids, is an innovative design that employs a biaxial distribution of voiding formers within the slab to reduce the slab’s self-weight while preserving a load-carrying capacity that is approximately comparable to that of solid slabs. This paper presents a new approach for figuring out the effective critical shear perimeter of voided slabs using the reduced-volume concept of concrete. This approach aims to reduce the coefficient of variation of the current design standards, namely the ACI 318-19 and Eurocode 2, for assessing the slabs’ resistance to punching shear. Our experimental program investigated the impact of voiding former patterns and the location of an opening near a column on the punching shear resistance of biaxial hollow slabs. The factors under consideration included the opening’s size, location, and distance from the loaded area, as well as the voiding formers’ placement concerning the critical shear boundaries. The results of experiments on 10 full-scale, 2000 × 2000 × 230 mm, reinforced concrete biaxial voided slabs with an opening are presented in this study. Two design expressions were used to estimate the biaxial hollow slabs’ shear strength. These expressions take into account the reduced volume of concrete and the distribution of voiding formers up to the section from the periphery of the column. The proposed approach to determine the effective punching shear perimeter has the lowest coefficient of variation among the methods suggested by these standards. This indicates the validity of our proposed expressions. The coefficient of variation of the proposed expressions does not exceed 0.057.
In this work polymeric composites were done from unsaturated polyester as a matrix reinforced with glass fiber type (E-glass) with two different volume fraction 20% & 40%. Fatigue tests showed that the number of fatigue cycles to failure limit for samples reinforced with uniform (woven Roving 0-90°) E-glass fiber and random (continuous fibers) with volume fraction 40% more than that for the same samples with volume fraction 20%. Also the fatigue results showed that the uniform samples failed with fatigue cycles more than that of random.
This study aims to evaluate the performance of emergency departments according to international standards through studying the performance in some of Iraqi public hospitals, where the evaluation performance is considered one of the important topics that take a great deal of officials' attention, especially decision makers in health organizations.
The researcher has derived the research idea from the importance of work in emergency department in hospitals and to what it provides of medical services and quick and immediate nursing care that help in patients' lifesaving, and it is the mirror that reflects the real image for the hospital
... Show MoreThe aim of this paper is to design suitable neural network (ANN) as an alternative accurate tool to evaluate concentration of Copper in contaminated soils. First, sixteen (4x4) soil samples were harvested from a phytoremediated contaminated site located in Baghdad city in Iraq. Second, a series of measurements were performed on the soil samples. Third, design an ANN and its performance was evaluated using a test data set and then applied to estimate the concentration of Copper. The performance of the ANN technique was compared with the traditional laboratory inspecting using the training and test data sets. The results of this study show that the ANN technique trained on experimental measurements can be successfully applied to the rapid est
... Show MoreIn this paper, an analytical solution describing the deflection of a cracked beam repaired with piezoelectric patch is introduced. The solution is derived using perturbation method. A novel analytical model to calculate the proper dimensions of piezoelectric patches used to repair cracked beams is also introduced. This model shows that the thickness of the piezoelectric patch depends mainly on the thickness of the cracked beam, the electro-mechanical properties of the patch material, the applied load and the crack location. Furthermore, the model shows that the length of the piezoelectric patches depends on the thickness of the patch as well as it depends on the length of the cracked beam and the crack depth. The additio
... Show MoreIn this paper, an analytical solution describing the deflection of a cracked beam repaired with piezoelectric patch is introduced. The solution is derived using perturbation method. A novel analytical model to calculate the proper dimensions of piezoelectric patches used to repair cracked beams is also introduced. This model shows that the thickness of the piezoelectric patch depends mainly on the thickness of the cracked beam, the electro-mechanical properties of the patch material, the applied load and the crack location. Furthermore, the model shows that the length of the piezoelectric patches depends on the thickness of the patch as well as it depends on the length of the cracked beam and the crack depth. The additional flexibil
... Show Morethe rationalization of energy consumption Require awareness in the possibility of bridging the local need severe shortage of electric power for daily requirements. The research aims to show that the engineers of various specializations and architects, including in particular can have an active role in about the importance of the role of energy in human life, and it’s best utilization without extravagance (which our religion forbids it). Here lies the problem of the research to find possible means and alternative methods to reduce (rationalization) electrical energy consumption in hot dry areas in general which need large energy for air conditioning because of the crucial climate of these regions that making access to the area o
... Show MoreThis study evaluates the flexural behavior of ultra-thin (50 mm) one‑way reinforced‑concrete (RC) slabs retrofitted with near‑surface mounted (NSM) carbon‑fiber‑reinforced polymer (CFRP) rods under quasi‑static loading. T300‑grade CFRP rods (≈4 mm diameter) were bonded in pre‑cut 7 mm × 7 mm grooves using a two‑part epoxy. As a proof-of-concept experimental baseline, three simply‑supported specimens (1000 mm × 500 mm × 50 mm) were tested in a six‑point bending configuration (four applied loads + two reactions): two conventional controls and one strengthened slab. A load‑control rate of ~15 kN/min was applied; the controls were cycled twice and the strengthened slab four times. Relative to the average of
... Show MoreThis research is qualitative in nature. It aims to investigate descriptively, analytically, and comparatively the modern AK model represented by the Sudan Open University Series, and the European framework, the common reference for Teaching Foreign Languages, to uncover what was achieved in them in terms of communication and language use. Accordingly, an integrated, multi-media approach has been adopted to enable the production and reception activities, and the spread of Arabic in vast areas of the world. Such a spread helps Arabic language to be in a hegemonic position with the other living languages. The study is based on getting benefit from human experiences and joint work in the field of teaching Arabic to non-Arabic speakers to mee
... Show MoreSilicon (Si)-based materials are sought in different engineering applications including Civil, Mechanical, Chemical, Materials, Energy and Minerals engineering. Silicon and Silicon dioxide are processed extensively in the industries in granular form, for example to develop durable concrete, shock and fracture resistant materials, biological, optical, mechanical and electronic devices which offer significant advantages over existing technologies. Here we focus on the constitutive behaviour of Si-based granular materials under mechanical shearing. In the recent times, it is widely recognised in the literature that the microscopic origin of shear strength in granular assemblies are associated with their
The effect of adding sand on clayey soil shear strength is investigated in this study. Five different percentage of clay-sand mixtures are used; 100% clay with 0% sand termed 100C, 60% clay with 40% sand termed 60C-40S, 30% clay with 70% sand termed 30C-70S, 15% clay with 85% sand termed 15C-85S, and as well as 100% sand termed 100S. The used clay was obtained from Baghdad city in Iraq and classified as CH soil, while the used sand was taken from Al-Khider area from Iraq and classified as SW soil. The initial dry unit weight for all mixtures is 16 kN/m3. The results show that the variations of the soil shear strength properties with soil components content changes