Preferred Language
Articles
/
MhYcU4cBVTCNdQwCfUU6
The reliability of surgeons to avoid traumatic insertion of dental implants into high-risk regions: a panoramic radiograph study
...Show More Authors
Abstract<sec><title>Background

The posterior regions of the jaws usually represent a significant risk for implant surgery. A non-valid assessment of the available bone height may lead to either perforation of the maxillary sinus floor or encroachment of the inferior alveolar nerve and consequently to implant failure. This study aimed to evaluate the reliability of surgeon’s decision in appraising the appropriate implant length, in respect to vital anatomical structures, using panoramic radiographs.

Methods

Only implants that are inserted in relation to the maxillary sinus (MS) or the mandibular canal (MC) were enrolled (first premolars [1P], second premolars [2P], first molars [1M], and second molars [2M]). All preoperative panoramic radiographs were evaluated under standard conditions. The postoperative estimation (under/over) was determined depending on the available bone height (ABH) measured from the apical end of the implant to the floor of the MS and the roof of the MC using cone beam computed tomography (CBCT). Any complication or side effect that associated with overestimated implants insertion was recorded.

Results

The study sample included 73 patients (predominantly females) who had consecutively received 148 implants, of which 68 were inserted in the posterior maxilla and 80 in the posterior mandible. Underestimation was recorded in 93.2% of the measurements. The remaining bone height after implants insertion was < 2 mm in the majority of underestimated cases (73.9%); they were significantly (P < 0.01) more than sites with remaining bone ≥ 2 mm (26.1%). In the posterior mandible, overestimation was significantly higher than posterior maxilla. Five cases with transient paresthesia were reported in the mandibular overestimated implants.

Conclusions

This study specified that surgeon’s choice of implants length, based on panoramic radiographs, was reliable regarding the incapability to insert implants with further length in the majority of underestimated cases, the low percent of overestimated measurements, and the minor associated complications.

Scopus Crossref
View Publication
Publication Date
Sat Jul 09 2022
Journal Name
Optik
The role of Ag NPs in PVA electrospun NFs for ultra-high sensitivity photodetector
...Show More Authors

This work aimed to produce PVA and PVA/Ag nanofibers ultra-high sensitivity photodetector by electrospinning. The electrospinning process was used to successfully prepare PVA nanofibers and a PVA-Ag nanofiber composite. FE-SEM, XRD, UV, I-V characterizations are used to study the morphological, structural, optical, and electrical properties of the material. In contrast, the PVA-Ag nanofiber composite film displayed a cubic structure with favored orientation (200) that indicated the presence of Ag NPs in the PVA-Ag nanofibers film. While the optical energy gap for PVA was 3.96 eV, it was only 2.14 eV for PVA-Ag nanofibers composite film, making this composite sensitive to visible light, particularly green light at 550 nm with a 65% photosens

... Show More
Scopus (7)
Scopus
Publication Date
Wed May 31 2017
Journal Name
Journal Of Engineering
Evaluating the Performance of High Modulus Asphalt Concrete Mixture for Base Course in Iraq
...Show More Authors

In the 1980s, the French Administration Roads LCPC developed high modulus mixtures (EME) by using hard binder. This type of mixture presented good resistance to moisture damage and improved . mechanical properties for asphalt mixtures including high modulus, good fatigue behaviour and excellent resistance to rutting. In Iraq, this type of mixture has not been used yet. The main objective of this research is to evaluate the performance of high modulus mixtures and comparing them with the conventional mixture, to achieve this objective, asphalt concrete mixes were prepared and then tested to evaluate their engineering properties which include moisture damage, resilient modulus, permanent deformation and fatigue characteristics. These prope

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 01 2018
Journal Name
Journal Of Colloid And Interface Science
Impact of nanoparticles on the CO2-brine interfacial tension at high pressure and temperature
...Show More Authors

Hypothesis Nanofluid flooding has been identified as a promising method for enhanced oil recovery (EOR) and improved Carbon geo-sequestration (CGS). However, it is unclear how nanoparticles (NPs) influence the CO2-brine interfacial tension (γ), which is a key parameter in pore-to reservoirs-scale fluid dynamics, and consequently project success. The effects of pressure, temperature, salinity, and NPs concentration on CO2-silica (hydrophilic or hydrophobic) nanofluid γ was thus systematically investigated to understand the influence of nanofluid flooding on CO2 geo-storage. Experiments Pendant drop method was used to measure CO2/nanofluid γ at carbon storage conditions using high pressure-high temperature optical cell. Findings CO2/nano

... Show More
Scopus (85)
Crossref (87)
Scopus Clarivate Crossref
Publication Date
Sat Apr 01 2023
Journal Name
Baghdad Science Journal
A Theoretical Study of the Docking of Medicines with some Proteins
...Show More Authors

A set of ten drug compounds containing an amino group in the structure were determined theoretically. The parameters were entered into a model to forecast the optimal values of practical (log P) medicinal molecules. The drugs were evaluated theoretically using different types of calculations which are AM1, PM3, and Hartree Fock at the basis set (HF/STO-3G). The Physico-chemical data like (entropy, total energy, Gibbs Free Energy,…etc were computed and played an important role in the predictions of the practical lipophilicity values. Besides, Eigenvalues named HOMO and LUMO were determined. Linearity was shown when correlated between the experimental data with the evaluated physical properties. The statistical analysis was used to analy

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (4)
Scopus Crossref
Publication Date
Sun Feb 03 2019
Journal Name
Iraqi Journal Of Physics
A study of the characterization of CdS/PMMA nanocomposite thin film
...Show More Authors

Nanocomposites of polymer material based on CdS as filler
material and poly methyl methacrylate (PMMA) as host matrix have
been fabricated by chemical spray pyrolysis method on glass
substrate. CdS particles synthesized by co-precipitation route using
cadimium chloride and thioacetamide as starting materials and
ammonium hydroxide as precipitating agent. The structure is
examined by X-ray diffraction (XRD), the resultant film has
amorphous structure. The optical energy gap is found to be (4.5,
4.06) eV before and after CdS addition, respectively. Electrical
activation energy for CdS/PMMA has two regions with values of
0.079 and 0.433 eV.

View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Fri Mar 31 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
A Study of the Furocoumarin Derivative of Ruta Chalepensis L. (Rutaceae)
...Show More Authors

  The content of Furocoumarin derivatives (Psoralens) of Ruta Chalepensis L. (Whole plant) was studied by simple extraction with petroleum ether (b.p. 60-80Co). The results indicated that the plant contains a total of about (0.015%).

       Investigation of these compounds by thin layer chromatography (TLC) revealed the presence of at least four compounds of which methoxsalen (8-methoxypsoralen) was isolated.     It was identified and authenticated with a standard by spectral method, IR, NMR, Mass spectra and HPLC.This plant could be considered as a good source for supplying this compound, which is widely used in dermatological preparations.

View Publication Preview PDF
Crossref
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Indoor risk assessment of radon gas in the science college buildings-University of Mustansiriyah using RAD-7 detector
...Show More Authors

In the present work, a set of indoor Radon concentration measurements was carried out in a number of rooms and buildings of Science College in the University of Mustansiriyah for the first time in Iraq using RAD-7 detector which is an active method for short time measuring compared with the passive method in solid state nuclear track detectors (SSNTD's). The results show that, the Radon concentrations values vary from 9.85±1.7 Bq.m-3 to 94.21±34.7 Bq.m-3 with an average value 53.64±26 Bq.m-3 which is lower than the recommended action level 200-300 Bq/m3 [ICRP, 2009].
The values of the annual effective dose (A.E.D) vary from 0.25 mSv/y to 2.38 mSv/y, with an average value 1.46±0.67 mSv/y which is lower than the recommended the rang

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Mar 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
Bruxism and Sleep Quality Among Iraqi Dental Students
...Show More Authors

Background: Undergraduate dental students are more susceptible to situations of stress that affected quality of sleep, such profiles of stress may result in sleep bruxism and/or awake bruxism, parafunctions that can affect oral and general health. The aim of the study was to evaluate the association of sleep bruxism, awake bruxism and sleep quality among dental students. Materials and methods: A cross-sectional study was performed including 260 Iraqi dental students from university of Baghdad aged from 20to25years old. Students enrolled in the third and fifth class participated in the study. The Pittsburgh Sleep Questionnaire Index (PSQI) was used for data collection. The PSQI was distributed during lecture classes. Sleep bruxism and awake

... Show More
View Publication
Crossref
Publication Date
Mon Mar 13 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Buccal Cortical Bone Thickness in Iraqi Arab Adults by Cone Beam Computed Tomography for Orthodontic Mini-Implants
...Show More Authors

ABSTRACT Background: Cortical bone thickness is important for the stability of mini implants. Placing mini implants in sites of favorable cortical bone thickness would guarantee better initial stability and long-term success. The aim of this study was to investigate gender, side and jaw differences of the buccal cortical bone thickness as a guide for orthodontic mini screw placement. Materials and Methods: The sample was selected from the patients attending the Specialized Health Center in Al-Sadr City / 3D department. Thirty patients (15 males and 15 females) were selected and cone beam computerized tomographic images were done. Then the buccal cortical bone thickness was measured at thirteen inter radicular sites in the maxilla and mandib

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Fri Jul 24 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Beta angle in a sample of Iraqi adults with Class I skeletal and dental relations and its correlation with other craniofacial measurements
...Show More Authors

Background: This study aimed to determine the value of Beta angle for a sample of Iraqi adults with class I skeletal and dental relations and to verify the existence of sexual dimorphism and to find out the relation between this angle and other craniofacial measurements. Materials and Methods: Sixty dental students (23 males and 37 females) with an age ranged between 20-31 years old and having class I skeletal and dental relations were chosen for this study. Each student was subjected to clinical examination and digital true lateral cephalometric radiograph. The radiographs were analyzed using AutoCAD 2007 computer program to measure the angular and linear variables. Descriptive statistics were obtained for the measurements for both genders

... Show More
View Publication Preview PDF