Background: The emergence of vaping as a popular alternative to traditional smoking has raised concerns regarding its potential impact on oral health. specifically affects the oral health of dental students, who are not only consumers of these products but also future practitioners tasked with educating patients on oral hygiene and health risks. purpose: This study investigated the dental and oral health impact of VAPE among male dental students. Methods: A self-administered questionnaire comprising 20 questions was meticulously designed to gather relevant data about their VAPE use and its implications on dental and oral health. Results: 43% of participants reported using VAPE, predominantly employing salt nicotine (48.8%) over free base nicotine (27.9%). The dental health statuses, assessed using the Decayed, Missing, and Filled Teeth (DMFT) index, showed that 35.6% had a DMFT score of 3 or higher, while 37.6% had scores below 3, and 26.7% reported a DMFT of 0. Most participants (57.4%) visited the dentist rarely, with no distinction between VAPE users and non-users. However, significant differences in aspects such as breathing, sleep quality, and fitness were noted between VAPE users and non-users (p:0.002, p:0.05, and p:0.00; p<0.05), respectively. Conclusion: As E-cigarettes smoking is becoming more widely growing habit within the young age group, more oral and physiological consequences begin to rise, such as a significantly higher prevalence of mouth dryness, cough and ultimately, worsened bodily functions including a lower breathing quality and reduced level of fitness.
Background: Dental implants act as infrastructure for fixed restoration to look like as a natural tooth. Osseointegration is a biological events and considered as a base for success of dental implant. The aim of this study is to evaluate the bond strength between bone and Ti implant coated with mixture of nano hydroxyapatite-chitosan-collagen compared with Ti implants coated with nano hydroxyapatite implanted in rabbit tibia, after different period of implantation time (two and six weeks) by torque removal test. Material and methods: 36 screws of commercially pure titanium; 8mm in length and 3mm diameter , 18 screws coated with mixture of nano hydroxyapatite-chitosan-collagen and18 screws coated with nano hydroxyapatite by dip coating. St
... Show MoreBackground: The Initial (primary) stability is one of the factors that play an important role in the success of the dental implants. The purpose of this study was to evaluate the initial stability of dental implant with horizontal plate by using five analytical tests: insertion torque, removal torque, resonance frequency analysis, push-in test and pull-out test. Materials and methods: Two different lengths of dental implants (5mm and 10mm) were tested in this study; each dental implant was 4mm in diameter with a square threads shape of 1mm pitch and 0.5mm depth. The crestal area was 4.2mm diameter contained a right angle margin circumferential ring while the apical area was tapered with two self-tapping grooves. In this study, the initial s
... Show MoreThis study was to examine the effect of a mental training program, including a combination of autogenic training and imagery, on a number of mental skills and on the development of personality traits-psychological hardiness as well as conscientiousness, openness to experience, and neuroticism-in Adolescent male volleyball players. 60 adolescent male volleyball players (aged 15–17) participated in a two-group, pretest-posttest design. The experimental group (n = 30) completed 8-week mental skills training program, including imagery, self-talk, attention control, and relaxation, while the control group (n = 30) followed regular training. Psychological hardiness and selected personality traits were measured pre-and post-intervention using va
... Show MoreThe Effect of Chicken Eggshell Extract on Microhardness of Artificially Induced Dental Erosion in Permanent Teeth (In Vitro Study), Shatha A Abbas*, Alhan A Qasim
Titanium alloy (Ti-6Al-4V or Gr.23) was widely used as a dental alloy. In the current study, polymerization of eugenol (PE) on Gr.23 titanium alloys was conducted by an electrochemical process before and after being treated by Micro Arc Oxidation (MAO). The formed films were characterized by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), and X-ray diffraction (XRD). The corrosion behavior of Gr.23 alloy in an artificial saliva environment at a temperature range of 293–323 K has been studied and assessed by means of electrochemical polarization and impedance spectroscopy techniques. Three cases are taken into consideration; bare Gr.23, Gr.23 coated by PE, and Gr.23 coated by PE after MAO treatment. The maxi
... Show MoreThe aim of this research is to find out the impact of cognitive incompatibility schemes on the development of creative thinking skills among first grade students.
To prove the objective of the research, the researcher put the following hypothesis:
There is no statistically significant difference at the level of (0.05) between the average score of the experimental group who study the history of ancient civilizations according to the patterns of cognitive conflict and the average grades of the control group students who study the same subject in the usual way in the test of post-creative thinking skill
This research aims to identify the impact of the selective model in acquiring the concepts of Kurdish grammar among female students in the eighth grade, and to achieve the goal of research, the researcher selected the experimental design with partial control and dimensional testing; the sample includes basic schools in the Chim district of Chamal/ Sulaymaniyah and randomly selected the basic school (Maha Bad) to be the field of application of the experiment and the random drawing method was chosen: two out of three sections and the number of students of the two sections is (75) students; section (C) represents the experimental group that studied the rules according to the selective model and its number is (37) students, while secti
... Show MoreThis study aims to fabricate and assess the β-tricalcium phosphate (β-TCP) bioactive ceramic coat layer on bioinert ceramic zirconia implants through the direct laser melting technique by applying a long-pulsed Nd:YAG laser of 1064 nm. Surface morphologies, adherence, and structural change in the coatings were evaluated by optical microscopy, field emission scanning electron microscope, hardness, and x-ray diffractometer. The elastic modulus (EM) of the coating was also determined using the nanoindentation test. The quality of the coating was improved when the laser power was 90 W with a decrease in the scan speed to 4 mm s−1. The chemical composition of the coat was maintained after laser processing; also, the Energy Dispersive
... Show More