Background: The aim of this study was to evaluate and compare the apical microleakage around retrograde cavities prepared with ultrasonic technique and filled with (Biodentine™) Materials and methods: 40 extracted single rooted human permanent maxillary teeth with mature apices were selected. The roots were prepared chemo-mechanically using k-files with crown-down technique and then obturated with lateral condensation gutta-percha technique. Teeth were divided into four main groups according to the cavity preparation method either manual or ultrasonic technique: Group A (n=10): A class I retrograde cavity at root end was prepared with traditional handpeice equipped and placement of Biodentine with manual condensation. Group B (n=10): A class I retrograde cavity at root end was prepared with Piezoelectric ultrasonic device equipped with ultrasonic tip with only manual compaction of the material. Group C (n=10): traditional handpeice and placement of Biodentine using both manual compaction and 5 second ultrasonic activation. Group D (n=10): Piezoelectric ultrasonic device and placement of Biodentine with both manual compaction and 5 second ultrasonic compaction. The teeth were immersed in 1% aqueous Methylene blue dye for 72 hr. Then they were sectioned longitudinally with a diamond disc and the depth of dye penetration was examined under high magnification 20X. Results: Statistical analysis showed a highly significant difference in microleakage among the tested groups in which Piezoelectric technique has proved superiority in retrograde cavity preparation and compaction of Biodentin when dye penetration scores were compared. So microleakage was highest with cavities prepared with handpeice and manual application of retrograde material group A (2.73±0.39) followed by microprepared cavities group C (1.86±0.16), and it was lowest with ultrasonically-prepared cavities group B (1.09±0.28) and group D (0.26±0.19). Conclusion: ultrasonic preparation produced significantly less microleakage than conventional method. Also less microleakage was observed with ultrasonic compaction of Biodentin when compared with conventional method of compaction.
The current research tackles the self-efficacy and its relation to the cognitive assessment for the daily disturbances for the University of Baghdad students. Two criteria have been adopted to achieve the objectives of the research. The sample of this study consists of 200 male and female students who were chosen randomly. The data were analyzed statistically, revealing that the university students owned their own self-efficacy as well as a cognitive assessment for the daily disturbances and they recognized them as self-threatening. The results also indicated the existence of a prediction activity in the field of the cognitive assessment to the daily disturbances selection. In light of the acquired results, the study recommends the neces
... Show MoreThe beginning of COVID-19 in Wuhan, China in late December 2019 and its worldwide transmission has led the World Health Organization to formally address the pandemic. The pandemic has imposed influential impacts on different environmental, economic, social, health, and living aspects. Publishing in scholastic journals was not immune from these impacts.
تم استخدام خرائط ضبط الجودة الإحصائية لتقييم جودة الخدمة التعليمية في جامعة الباحة، ويهدف هذا البحث إلى استخدام خرائط ضبط الجودة الإحصائية لقياس مستوى الجودة وفجوة الجودة بين توقعات الطلبة وإدراكاتهم لمستوى الخدمة الذي تقدمه جامعة الباحة. حيث تم اختيار عينة من 200 طالب وطالبة عشوائيا باستخدام العشوائية العنقودية من 4 كليات خلال الفترة 01 – 30/2015م، وجمعت البيانات من خلال استبيان جودة الخدمة الذي يقيس ت
... Show MoreThree mesoporous silica with different functional group were prepared by one-step synthesis based on the simultaneous hydrolysis and condensation of sodium silicate with organo - silane in the presence of template surfactant polydimethylsiloxane - polyethyleneoxide (PDMS - PEO). The prepared materials were characterized by Fourier transform infrared spectroscopy (FTIR), thermogravimetric analysis (TGA), atomic force microscopy (AFM) and nitrogen adsorption/desorption experiments. The results indicate that the preparation of methyl and phenyl functionalized silica were successful and the mass of methyl and phenyl groups bonded to the silica structure are 15, 38 mmol per gram silica. The average diameter of the silica particles are 103.51,
... Show MoreThe purpose of my thesis is to synthesis two new bidentate ligands which were used to prepare series of metal complexes by reacting the ligands with (M+2 = Mn, Co, Ni, Cu, Cd and Hg) Succinyl chloride was used as starting material to synthesis two bidentate ligands (L1) and (L2) by reaction it with 4-chloroaniline (L1) and (4-aminoacetophenone) (L2) in dichloromethane as a solvent, that are: (L1) = N1,N4-bis (4-chloro phenyl ) succinamide (L2) =N1,N4-bis(4-acetylphenyl)succinamide The new ligands were characterize by using spectroscopic study (Fourier-transform infrared spectroscopy (FT-IR), electronic spectra ( UV-Vis) ,nuclear magnetic resonance(1H,13C-NMR), Mass spectra
... Show More