In the present study, radon gas concentration in the shallow groundwater samples of the Abu-Jir region in Anbar governorate was measured by using Rad-7 detector. The highest radon gas level in the samples is up to 9.3 Bq/L, while the lowest level is 2.1 Bq/L, with an average of 6.44±1.8 Bq/L. The annual effective dose is varied from 33.945 μSv/y to 7.66 μSv/y, with an average of 0.145±0.06 μSv/y. Consequently, the radon level in the groundwater studied is lower than the standard recommended value (11 Bq/L) reported by the United States Environmental Protection Agency (USEPA). The potential source of radon is uranium-rich hydrocarbons that are leakage to the surface along the Abu-Jir Fault. This research did not indicate any risk that radon gas concentrations may occur in the groundwater in the study area, and despite this, the research strongly recommends to propose a new Iraqi specification that defines the permissible level of radon gas concentrations in the groundwater and air to avoid harm to human health and will be an Iraqi standard that will be applied for the first time in Iraq.
Alternative distribution to estimate the Dose – Response model in bioassay excrement
This research concern to study five different distribution (Probit , Logistic, Arc sine , extreme value , One hit ), to estimate dose –response model by using m.l.e and probit method This is done by determining different weights in each distribution in addition find all particular statistics for vital model .
A major disadvantage of dose reconstruction by means of thermoluminescence (TL) is the fact that during readout of any TL material exposed to ionizing radiation (i.e., during measuring the glow curve), the radiation-induced signal gets lost. Application of the photo-transferred thermoluminescence phenomenon (PTTL) may offer a solution to this problem. In PTTL, the residual signal that is not destroyed by conventional TL readout (because it comes from deeper electron traps) can be readout through simultaneous stimulation by UV light and heating, allowing to obtain information about the absorbed dose in a second run. The present paper describes the application of PTTL for emergency dose assessment. For
Radon and its daughters are of the natural radioactive decay of the uranium series. Exposure to radon gas leads to lung cancer, so the risks are significantly higher for smokers than for non-smokers. Therefore, the risk of radon increases for both active and passive smokers. The radioactivity of alpha particles emitted by radium 226, the main source of radon 222, has become harmful because its prevalence and inhalation increase with increased smoking. In this study, a CR-39 detector was used to measure radon, radium, and uranium concentrations and then calculate risk parameters in seven cigarette-smoking females in vitro study of human blood samples, and three normal females with no actual and passive cigarette smoking. The
... Show MoreIn the present study twenty samples of human urine were taken
from healthy male and female with different of: ages, occupation and
place of residence. These samples were collected from the hospital to
measure the concentration of radon gas in human urine by using one
of solid state nuclear track detectors LR-115.
The results obtained of the concentrations of radon in healthy human
urine are varying from 2.12×10-3 Bq.l-1 to 4.42×10-3 Bq.l-1 and
these values are less than the allowed limits 12.3×10-3 Bq.l-1.
The objective of this research was to estimate the dose distribution delivered by radioactive gold nanoparticles (198 AuNPs or 199 AuNPs) to the tumor inside the human prostate as well as to normal tissues surrounding the tumor using the Monte-Carlo N-Particle code (MCNP-6.1. 1 code). Background Radioactive gold nanoparticles are emerging as promising agents for cancer therapy and are being investigated to treat prostate cancer in animals. In order to use them as a new therapeutic modality to treat human prostate cancer, accurate radiation dosimetry simulations are required to estimate the energy deposition in the tumor and surrounding tissue and to establish the course of therapy for the patient. Materials and methods A simple geometrical
... Show MoreBackground: Phosphodiesterase-5 (PDE-5) inhibitorsrestore nitric oxide (NO) signaling and may reducecirculating inflammatory markers, and improve metabolicparameters through a number of mechanisms. Dailyadministration of the PDE-5 inhibitor, tadalafil (TAD) mayattenuate inflammation; improve fasting plasma glucose andtriglyceride levels and body weight. This study aims toevaluate the efficacy of low dose PDE-5 inhibitor, tadalafil(TAD) in controlling dysglycemia and body weight in obesediabetic men.Methods: Forty obese men with type 2 diabetes aged 30-50years incorporated in this study, all with A1c of 7-8.5%,attending obesity unit in AL-Kindy college of medicine.Weight, height, BMI, FPG, A1c, cholesterol, TG, HDL andLDL measured for all
... Show MoreThis study aims to know the extent of the impact of Strategic Leadership as an independent variable in Strategic Learning as a dependent variable to help the senior leadership in Anbar University to take the right decisions to develop Strategic Learning programs in light of the circumstances of the Covid-19 and the sudden decisions adopted by the university to switch to E-learning and to blend. The survey was conducted by distributing a questionnaire that was adopted as a primary tool in data collection from the study sample represented by the university's senior leaders, An intentional random sample of (105) was selected from our community of (127), the data were analyzed by (SPSS) Depe