Preferred Language
Articles
/
LhbHCYoBVTCNdQwCKZAU
Sensing Performance of Modified Single Mode Optical Fiber Coated With Nanomaterials-Based Ammonia Sensors Operated in the C-Band
...Show More Authors

Scopus Clarivate Crossref
View Publication
Publication Date
Sun Jun 12 2022
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Effectiveness of Ombitasvir with Paritaprevir/Ritonavir plus Ribavirin on the Treatment of Naïve Patients with Chronic Hepatitis C Virus Genotype 4
...Show More Authors

Background Direct-acting antivirals (DAAs) combination therapies from various mechanisms of action and families have been revolutionized the management landscape of chronic hepatitis C virus (HCV). Ombitasvir, paritaprevir with ritonavir (OBV/PTV/r) ± ribavirin (RBV) is approved to treat HCV genotype 4 (GT4) infection. Here, our objective was to delineate the efficacy and safety of OBV/PTV/r plus RBV in treating of Egyptian naïve patients infected with HCV GT4.

Methods a cohort of 100 Egyptian patients infected with HCV GT4 was allocated and administered orally OBV/PTV/r with RBV. The primary endpoint of our study was a sustained virological response (HCV RNA < 12 IU/mL) 12 weeks after the c

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Journal Of Medicine And Life
Effect of commercially pure titanium implant coated with calcium carbonate and nanohydroxyapatite mixture on osseointegration
...Show More Authors

In this research, rabbit femurs were implanted with CP Ti screws coated with a combination of CaCO3 and nanohydroxyapatite, and the effect on osseointegration was assessed using histological and histomorphometric examination at 2 and 6 weeks. CaCO3 and nanohydroxyapatite were combined with the EPD to coat the surfaces of the CP Ti screws. The femurs of five male rabbits were implanted with coated and uncoated implant screws. Healing time was divided into two groups (2 and 6 weeks). After 2 and 6 weeks of implantation, the histological examination revealed an increase in the growth of bone cells for coated screws, and the histomorphometric analysis revealed an increase in the percentage of ne

... Show More
View Publication
Scopus (11)
Crossref (11)
Scopus Crossref
Publication Date
Tue Mar 31 2015
Journal Name
Al-khwarizmi Engineering Journal
Dual Measurements of Pressure and Temperature With Fiber Bragg Grating Sensor
...Show More Authors

Abstract

The fiber Bragg grating (FBG) technology has been rapidly applied in the sensing technology field. In this work, uniform FBG was used as pressure sensor based on measuring related Bragg wavelength shift. The pressure was applied directly by air compressor to the sensor and the pressure was ranged from 1 to 6 bar.

      This sensor also was affected by the external temperature so as a result it could be used as a temperature sensor. This sensor could be used to monitor the pressure of dams. It has been shown from the result that the sensor is very sensitive to the pressure and the sensitivity was (67 pm\bar) and is very sensitive to temperature and the sensitivity was (10p

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 05 2023
Journal Name
Journal Of Engineering
Compressive Behavior of Fiber Reinforced Concrete Columns Rehabilitated with CFRP Warps
...Show More Authors

Over the last few years, there has been a worldwide increase in the use of composite materials for rehabilitation of deficient reinforced concrete structures. One important application of this technology is the use of Carbon Fiber Reinforced Polymer (CFRP) jacket to provide external confinement of reinforced concrete columns. Square concrete column specimens 100×100×1000 mm with concrete
compressive strength of about 30 and 50 MPa, steel fiber volume fraction 0%, 0.5%, 0.75%, and percentage of longitudinal reinforcement 2.01%, 3.14% and 4.52% were tested until failure in previous research. In this research seven tested columns were repaired and rehabilitated using one layer of CFRP flexible wraps and tested to determine their ultim

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Oct 01 2020
Journal Name
Engineering Science And Technology, An International Journal
Thermal performance improvement based on the hybrid design of a heat sink
...Show More Authors

View Publication
Scopus (4)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Tue Sep 01 2009
Journal Name
2009 5th International Conference On Wireless Communications, Networking And Mobile Computing
Spectrum Sensing Opportunities in Cognitive Radios
...Show More Authors

Cognitive radio is observed as a new approach, which could be cope with the spectral limitations. This approach is designed to detect whether a particular segment of the radio spectrum is currently in use and to jump into the temporarily unused spectrum rapidly without interfering with the transmissions of other users. CR is the promising radio technology which aims to detect and utilize the temporally unused spectrum bands by sensing its radio environment in order to improve spectrum utilization. To enhance the sensing performance, cooperative spectrum sensing has been proposed. However, when the number of cognitive user tends to be very large, the bandwidth for reporting sensing results to the common receiver will be very huge. In this pa

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Wed Apr 27 2022
Journal Name
Arabian Journal For Science And Engineering
Optical and Thermal Performance of a Parabolic Trough Collector for Different Receiver Geometries
...Show More Authors

This paper numerically and theoretically investigates the optical and thermal performance of a parabolic trough collector PTC system. Many numerical simulations and theoretical analyses are conducted to demonstrate the influence of the receiver geometry and shifting from the focal position on the optical performance. The examined receiver geometries are circular, square, triangular, elliptical, and the new circular–square combined geometry is named as channel receiver. The thermal performance of PTC is examined for different volume flow rates theoretically in the range of (0.36 to 2.4 lpm). The results show that the best optical design is the channel receiver with an intercept factor of 84%, while the worst is the elliptical receiver with

... Show More
View Publication
Scopus (17)
Crossref (9)
Scopus Crossref
Publication Date
Wed Jan 13 2021
Journal Name
Egyptian Journal Of Chemistry
Development of a nanostructured double-layer coated tablet based on polyethylene glycol/gelatin as a platform for hydrophobic molecules delivery
...Show More Authors

The aim of the current study was to develop a nanostructured double-layer for hydrophobic molecules delivery system. The developed double-layer consisted of polyethylene glycol-based polymeric (PEG) followed by gelatin sub coating of the core hydrophobic molecules containing sodium citrate. The polymeric composition ratio of PEG and the amount of the sub coating gelatin were optimized using the two-level fractional method. The nanoparticles were characterized using AFM and FT-IR techniques. The size of these nano capsules was in the range of 39-76 nm depending on drug loading concentration. The drug was effectively loaded into PEG-Gelatin nanoparticles (≈47%). The hydrophobic molecules-release characteristics in terms of controlled-releas

... Show More
View Publication Preview PDF
Scopus (16)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Fri Oct 22 2021
Journal Name
Iraqi Journal Of Physics
Absorption properties of novolac-alumina-graphite mixture microwave absorbers in x-band frequencies
...Show More Authors

Absorption properties (Attenuation coefficient, the percentage of the reflection, and the percentage of absorption) in x-band have been investigated in this paper for novolac – alumina- graphite mixture. Using novolac as the host material, the samples are prepared with alumina concentrations (5%,10%,15%,20%) and graphite concentrations (5%,10%) with thickness equal to 2.2mm .Network analyzer produced by HP-8510 was used in this work to measure the attenuation coefficient. The samples (3, 5) have good attenuation of wave with bandwidth of frequencies. The maximum of attenuation is -25dB at frequency 10.28GHZ in sample (3) which has concentrations (80%novolac,10%alumina,and 5% graphite) and -24 dB at frequency 10.56GHZ in sample (5) whic

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 01 2020
Journal Name
Annals Of Tropical Medicine And Public Health
Role of high sensitivity C - Reactive protein and some of heavy metals in patients with rheumatoid arthritis
...Show More Authors

View Publication
Scopus (7)
Crossref (4)
Scopus Crossref