The increasing demand for durable and multifunctional separation materials necessitates polymer‐based coatings that combine mechanical robustness with high selectivity. This study aims to develop antibacterial oil/water separation systems that effectively address challenges posed by microorganisms, which can decrease filter effectiveness and impact overall separation efficiency. Metal meshes were coated with titanium dioxide (TiO
2
), octadecanethiol (ODT), and polyvinylidene fluoride (PVDF) via spray coating using four formulations: TiO
2
, PVDF, TiO
2
/ODT, and TiO
2
/ODT/PVDF. PVDF‐containing coatings exhibited superior superhydrophobicity, with a water contact angle of 161° and a sliding angle of 3°, attributed to the dense nano‐roughened texture formed upon drying. The ODT contributed to uniform surface coverage, while PVDF imparted excellent adhesion and mechanical durability, maintaining self‐cleaning performance after 50 abrasion cycles. The TiO
2
/ODT/PVDF formulation demonstrated the highest oil/water separation efficiency and improved oil flux, highlighting the critical contribution of the polymer–nanoparticle interface. Moreover, the nanocomposite coating exhibited pronounced antibacterial activity against
Gingival carcinoma is a malignant neoplasm affecting the oral mucosa and is associated with significant morbidity and mortality. Allium ampeloprasum var. porrum water extracts have gotten a lot of attention because of their bioactive components, such as polyphenols, flavonoids, and alkaloids, which have a variety of pharmacological activities, including antiproliferative actions. This study aimed to evaluate the histological and molecular effects of Allium ampeloprasum (leek) water extract on the proliferation of the murine gingival cancer cell line. Histological evaluation was conducted to examine morphological changes induced by extract treatment. Molecular mechanisms underlying the observed histological changes were investigated
... Show MoreThe river water salinity is a major concern in many countries, and salinity can be expressed as total dissolved solids. So, the water salinity impact of the river is one of the major factors effects of water quality. Tigris river water salinity increase with streamline and time due to the decrease in the river flow and dam construction from neighboring countries. The major objective of this research to developed salinity model to study the change of salinity and its impact on the Al-Karkh, Sharq Dijla, Al-Karama, Al-Wathba, Al-Dora, and Al-Wihda water treatment plant along Tigris River in Baghdad city using artificial neural network model (ANN). The parameter used in a model built is (Turbidity, Ec, T.s, S.s, and TDS in)
... Show MoreThe study investigates the relationship between the volatility of the Iraqi Stock Exchange Index (ISX), and the volatility of global oil prices benchmarks, Brent and West Intermediate Texas (WTI), in additional to the Iraqi Oil, Basra Crude Light (BSL) which represents the most exported Iraqi oil and the major influential factor on the Iraqi governmental revenues. Using monthly data covering the period: 1/2005-12/1205, econometrical and technical tools represented by Co-incretion, Vector Error Correction Model – VECM, Granger Causality, and Bollinger band were employed in order to explore the relationship between the variables.
The econometric analysis revealed the impact of the oil prices volatility on
... Show MoreThis in vivo study was conducted to investigate the effect of different concentrations of ozonated water on experimentally skin infection with some of bacterial isolates (Pseudomonas aeruginosa and Staphylococcus aureus ) which Showed dermal infection in experimental animals after 48 hours of exposure to these Microorganisms. Results revealed that ozone has the power to accelerated the healing process depending on the perfect concentration of ozonated water used and the severity of infection & nature of causative agent , in which the recovering period was 7 days for the infection caused by P. aeruginosa and 5 day for S.aureus by using the concentration 60 µg/ml . Results also indicated in this study the stimulated effect of O
... Show Moreتصف هذه الدراسة تطوير تقنية سهلة ورخيصة ودقيقة وسريعة لقياس 4-اثيل فينول وتنطوي الطريقة الأولية على تحويل -3 نيترو انيلين إلى ملح ديازونيوم ثم التفاعل مع 4 - إثيل فينول في وسط قلوي.المعقد المتكون هو أصفر اللون وله امتصاص عند اعلى طول موجي عند 426 nm. ويتبع قانون بير في مدى خطي قدره 5-12 μg mL-1 مع معامل ارتباط قدره 0.994 وامتصاص مولاري 6.0024x10^3 L.mol-1.cm-1 وتم استُخدِام تقنية نقطة السحابة لقياس كميات قليلة جدا من الفينول باس
... Show MoreThe driving idea for the present work was to combine the effect of polyvinyl alcohol (PVA) as corrosion inhibitor with the distance between the anodic and cathodic elements of the galvanic cell, beside their area ratio, in scope of synergistic suppression of galvanic corrosion on Cu/Fe model couple, using weight loss method. The performance affecting galvanic corrosion process has been tested for three major factors affect the process:
1. Four PVA inhibitor concentrations were selected to be (0, 1000, 4000 and 7000 ppm) in simulated cooling water.
2. Two cathode: anode area ratios as 1:1 and 2.4:1.
3. Two distances apart cathode – anode as 3 and 7 cm.
Maximum corrosion inhibition achieved was 86% which indicates that increa
This work provides a historical overview of water storage tanks used for solar energy collection, with a focus on the impact of different geometric configurations on thermal performance and energy storage efficiency. The designs of cylindrical, spherical, rectangular and triangular tanks were reviewed to analyse their effects on thermal gradients, heat retention and energy storage capacity. Within the scope of nominal processes, the study primarily aimed to identify the factors influencing the choice of tank shape in terms of size, capacity and aspect ratio. Another key objective was to assess what enhances heat storage in the tank to improve thermal efficiency. Comparing cylindrical shapes to other shapes, such as spherical, rectan
... Show MoreThe distribution of chilled water flow rate in terminal unit is a major factor used to evaluate the performance of central air conditioning unit. In this work, a theoretical chilled water distribution in the terminal units has been studied to predict the optimum heat performance of terminal unit. The central Air-conditioning unit model consists of cooling/ heating coil (three units), chilled water source (chiller), three-way and two-way valve with bypass, piping network, and pump. The term of optimization in terminal unit ingredient has two categories, the first is the uniform of the water flow rate representing in statically permanents standard deviation (minimum value) and the second category is the maximum heat transfer rate fro
... Show MoreOccurrence the heavy metals in water is one of the most important concerns. may cause savior health problems. In this work we made an attempt to know the quantity of six heavy metals in groundwater in different locations of Baghdad city. Examinations were made on groundwater of the review region to assess the heavy metals. Groundwater samples were gathered and analyzed utilizing Atomic Absorption Spectrophotometer for their Manganese, Iron, Zinc, Cadmium, Copper and Lead content and their levels compared with World Health Organization (WHO) specified maximum contaminant level. In order to accomplish this, water samples were obtained from 10 randomly selected wells in the region, in February and August, 2016. The study showed that the ground
... Show More