Preferred Language
Articles
/
LOY9sJwBmraWrQ4dB076
Electrochemical Deposition of Cu-Nanoparticle-Loaded CdSe/TiO2 Nanotube Nanostructure as Photoelectrode
...Show More Authors

Scopus Crossref
View Publication
Publication Date
Fri May 15 2020
Journal Name
Egyptian Journal Of Chemistry
Application of Response Surface Methodology for Optimization of Phenol Removal from Simulated Wastewater using Rotating Tubular Packed bed Electrochemical Reactor
...Show More Authors

View Publication
Scopus (5)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Mon May 01 2017
Journal Name
Desalination And Water Treatment
Cadmium removal from simulated chloride wastewater using a novel flow-by fixed bed electrochemical reactor: Taguchi approach
...Show More Authors

View Publication
Scopus (10)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Wed Oct 30 2024
Journal Name
Iraqi Journal Of Science
Enhancing Electrochemical Cells Performance with Modified Ionic Liquids and Deep Eutectic Solvents using Titanium Dioxide Nanoelectrodes- Graphite
...Show More Authors

Ionic liquids (ILs) and deep eutectic solvents (DESs) have been found to be highly effective as electrolytes in TiO2 NTAs-graphite cells when combined with additives that enhance conductivity by reducing the viscosity of these liquids. The presence of CaCl2.6H2O: Acetamide DES with DI water as an additive resulted in a cell voltage of 1.31V and an internal resistance of 19 ohm. This can be attributed to the concentration and quality of the ionic species. The cells exhibited an interesting response to the AlCl3-chloroacetamide IL with dichloromethane DCM as an additive, with a cell voltage of 1.81V and an internal resistance of 5.0 ohm. Once again, this is influenced by the quality and concentration of the ionic species. Furthermore,

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Sun Dec 01 2019
Journal Name
Al-khwarizmi Engineering Journal
An Experimental Study on Electrochemical Grinding Parameters on Hardness and Material Removal Rate for Stainless Steel 316
...Show More Authors

Electrochemical Grinding (ECG) process is a mechanically assisted electrochemical process for material processing. The process is able to successfully machine electrically conducting harder materials at faster rate with improved surface finish and dimensional control. This research studies the effect of applied current, electrolyte concentration, spindle speed and the gap between workpiece and tool on hardness and material removal rate during electrochemical grinding for stainless steel 316. The characteristic features of the electrochemical grinding process are explored through Taguchi-design-based experimental studies. The better hardness can be obtained at 10 A of the current, 150 g/l of the electrolyte concentration, 0.3 mm of gap an

... Show More
View Publication Preview PDF
Publication Date
Wed Feb 01 2023
Journal Name
Chemical Engineering Research And Design
Nickel removal from simulated wastewater using a novel bio-electrochemical cell with packed bed rotating cylinder cathode
...Show More Authors

View Publication
Scopus (8)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Sat Feb 22 2025
Journal Name
Al-rafidain Journal Of Medical Sciences ( Issn 2789-3219 )
In vivo Brain Pharmacokinetics of Dolutegravir Sodium-Loaded Nanostructured Lipid Carrier in situ Gel: Comparative Study with an Intravenous Drug Solution
...Show More Authors

Background: Dolutegravir sodium (DTG), used to treat HIV, faces challenges in delivering effective therapeutic concentrations to the brain due to the blood-brain barrier (BBB). Nanostructured lipid carriers (NLCs) combined with in situ gels present a promising strategy for enhancing brain drug delivery via the intranasal route. Objective: To compare brain pharmacokinetics of DTGs delivered via NLC-loaded in situ gel intranasal administration with the conventional intravenous (IV) drug solution. Methods: 80 Wistar rats, which were divided into three groups: two groups consisting of 39 animals each and a control group with 2 animals. Rats were administered with a dose of 1.0 mg/kg of DTGs IV, and DTGs NLC-loaded in situ gel were admin

... Show More
View Publication
Scopus (5)
Crossref (3)
Scopus Crossref
Publication Date
Sun Dec 22 2019
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Ex-vivo Ex-Vivo Absorption Study of a Novel Dabigatran Etexilate Loaded Nanostructured Lipid Carrier Using Non-Everted Intestinal Sac Model
...Show More Authors

Abstract

The purpose of our study was to develop Dabigatran Etexilate loaded nanostructured lipid carriers (DE-NLCs) using Glyceryl monostearate and Oleic acid as lipid matrix, and to estimate the potential of the developed delivery system to improve oral absorption of low bioavailability drug, different Oleic acid ratios effect on particle size, zeta potential, entrapment efficiency and loading capacity were studied, the optimized DE-NLCs shows a particle size within the nanorange, the zeta potential (ZP) was 33.81±0.73mV with drug entrapment efficiency (EE%) of  92.42±2.31% and a loading capacity (DL%) of 7.69±0.17%. about 92% of drug was released in 24hr in a controlled manner, the ex-vivo intestinal p

... Show More
View Publication Preview PDF
Scopus (16)
Crossref (7)
Scopus Crossref
Publication Date
Mon Jul 27 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The Electrophoretic Deposition of Nano Al2O3 and AgNO3 on CpTi Dental Implant (An in vitro and in vivo study)
...Show More Authors

Background: Even the wide use of dental implants, still there is a proportion of implants are failed due to infection. Much considerable attention has been paid to modify the implant surface. Coating of dental implant with a biocomposite material of suitable properties can improve osseointegration. And this is the main concern of this study. The aim of present study was to evaluate the use of a biocomposite coating of dental implant with (ceramic nano Al2O3 and metalic AgNo3) on the bond strength at bone – implant interface and tissue reaction. Materials and methods: A total number of forty-eight screws, CpTi dental implant used in this study. Half of these screws were coated with a biocomposite material of nano (Al2O3and AgNo3), thi

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Sun Jan 01 2017
Journal Name
Aip Conference Proceedings
Macro controlling of copper oxide deposition processes and spray mode by using home-made fully computerized spray pyrolysis system
...Show More Authors

View Publication
Scopus (6)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Mon Oct 17 2016
Journal Name
Proceedings Of The Institution Of Mechanical Engineers, Part B: Journal Of Engineering Manufacture
Development and control of shaped metal deposition process using tungsten inert gas arc heat source in additive layered manufacturing
...Show More Authors

Tungsten inert gas arc welding–based shaped metal deposition is a novel additive manufacturing technology which can be used for fabricating solid dense parts by melting a cold wire on a substrate in a layer-by-layer manner via continuous DC arc heat. The shaped metal deposition method would be an alternative way to traditional manufacturing methods, especially for complex featured and large-scale solid parts manufacturing, and it is particularly used for aerospace structural components, manufacturing, and repairing of die/molds and middle-sized dense parts. This article presents the designing, constructing, and controlling of an additive manufacturing system using tungsten inert gas plus wire–based shaped metal deposition metho

... Show More
View Publication
Scopus (13)
Crossref (9)
Scopus Clarivate Crossref