Moisture induced damage in asphaltic pavement might be considered as a serious defect that contributed to growth other distresses such as permanent deformation and fatigue cracking. This paper work aimed through an experimental effort to assess the behaviour of asphaltic mixtures that fabricated by incorporating several dosages of carbon fiber in regard to the resistance potential of harmful effect of moisture in pavement. Laboratory tests were performed on specimens containing fiber with different lengths and contents. These tests are: Marshall Test, the indirect tensile test and the index of retained strength. The optimum asphalt contents were determined based on the Marshall method. The preparation of asphaltic mixtures involved three contents of carbon fiber namely (0.10%, 0.20%, and 0.30%) by weight of asphalt mixture and three lengths including (1.0, 2.0 and 3.0) cm. The results of this work lead to several conclusions that mainly refer to the benefits of the contribution of carbon fibers to improving the performance of asphalt mixtures, such as an increase in its stability and a decrease in the flow value as well as an increase in voids in the mixture. The addition of 2.0 cm length carbon fibers with 0.30 percent increased indirect tensile strength ratio by 11.23 percent and the index of retained strength by 12.52 percent. It is also found that 0.30 % by weight of the mixture is the optimum fiber content for the three lengths.
The risk assessment for three pipelines belonging to the Basra Oil Company (X1, X2, X3), to develop an appropriate risk mitigation plan for each pipeline to address all high risks. Corrosion risks were assessed using a 5 * 5 matrix. Now, the risk assessment for X1 showed that the POF for internal corrosion is 5, which means that its risk is high due to salinity and the presence of CO, H2S and POF for external corrosion is 1 less than the corrosion, while for Flowline X2 the probability of internal corrosion is 4 and external is 4 because there is no Cathodic protection applied due to CO2, H2S and Flowline X3 have 8 leaks due to internal corrosion so the hazard rating was very high 5 and could be due to salinity, CO2, fluid flow rate
... Show More
Background: Polymethyl methacrylate (PMMA) is the most commonly used material in denture fabrication. The material is far from ideal in fulfilling the mechanical requirements, like low impact and transverse strength, poor thermal conductivity. The purpose of this study was to evaluate the effect of addition a composite of surface treated Nano Aluminum oxide (Al2O3) filler and plasma treated polypropylene fiber (PP) on some properties of denture base material. Materials and methods: One hundred fifty prepared specimens were divided into 5 groups according to the tests, each group consisted of 30 specimens and these were subdivided into 3 groups (unreinforced heat cured acrylic resin as control group),reinforced acrylic resin with( 0.5%wt Nan
... Show MoreThis study was carried out at the Dept. Hortic. and Land.Gard., Coll. Agric. Eng.Sci., University of Baghdad during fall season of 2019-2020, in order to evaluate the effect of nutrient solution type under hydroponic system (NFT) on growth, yield and quality of broccoli Brassica oleracea var.italica. Two experiments were carried out which were the standard solution experiment (Cooper) and the alternative solution experiment (ABEER) prepared from fertilizers. Results revealed that the type of solution used in the hydroponics system had non significant effect on the leaves content of N,K, Mg, Fe, Cu, B, Chlorophyll, leaves number, root length, weight of the main heads, number of side heads were not significantly affected. 13nt, refl
... Show MoreThe aim of this research sought to assess the background radiati on levels of medicinal plant samples in Iraq.The D, AED, and ELCRThe D values are 0.164 ± 0.006 µSv/h.The radiation dose outputs from the afore mentioned research were juxtaposed with the safety threshold of 0.247 µSv/h set by the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) in 2008 and the National Council on Radiation Pr otection and Measurements (NCRP) in 2009.The radiation exposure for all samples in this investigation is within the permissible limits.Additionally, t he AED values obtained from microsieverts per hour are (1.31 ±0.0326 mS v/y), indicating variability, with a maximum permissible limit of 2.4 mSv/y ear, as per t
... Show MoreThis study was performed on the Tigris River (Baghdad city section) during the period between December 2016 and December 2018 to assess seasonal variation in water quality using the Overall Index of Pollution (OIP). The OIP is one of the reliable tools for the assessment of surface water quality. To calculate OIP-values, eight parameters were measured ( pH, Dissolved Oxygen "DO", Biological Oxygen Demand "BOD", Total Dissolved Solid "TDS", Total Hardness "TH", calcium "Ca", Sulphate "SO4" and Alkalinity). The results showed the anthropogenic activities impact of Baghdad population that directly discharge of "inadequate treated" waste water to the river. OIP values were acceptable (1˃OIP˃ 1.7) in 2011, 2012, 2013 and 2018. However, in
... Show MoreAim: This study aimed to investigate the impact of rabbit serum on skin wound healing with the help of histological examination. Materials and Methods: A total of ten indigenous rabbits were used in this study. The animals were divided into two groups: control and serum- treated. The histological assessment was done with a paraffin embedding technique and the histological sections were stained with H&E stain. Results: Severe infiltration of polymorphonuclear leukocytes with severe fibrin deposits were seen in serum treated group at 2 days post-injury; at 7 days post-injury the changes revealed moderate fibroplasia, fibrin deposit and severe infiltration of both mononuclear and polymorphonuclear leukocytes; at 14 days post-inju
... Show MoreBackground: Ejection fraction have been used frequently
for assessment of the left ventricular function, but can be
associated with errors in which myocardial performance
index have been used as another parameter to measure the
left ventricular function.
Objective: selecting another echocardiography parameter
for the assessment of myocardial in function instead of the
ejection fraction.
Methods: 160 patients referred to the echocardiogram unit
from the period december 2007 to august 2008 requesting
assessment of left ventricular function. After clinical
examination, routine blood tests; chest x-ray and
electrocardiographic recording have been completed. All
patients informed to come for this unit af
Objective: To assess the nurses-midwives' knowledge and practices regarding the management of second stage
of labor and to find out the association between their knowledge and practices and socio-demographic
characteristics and working years and experience.
Methodology: A descriptive study was carried out from March 22nd
, 2008 through 30th June, 2008. A purposive
sample of (75) Nurse-Midwives which was selected from (6) hospitals. A questionnaire was comprised of two
parts: (socio-demographic characteristics and the assessment tool for Nurse-Midwives' knowledge and health
practices performed by them). The questionnaire validity was determined by experts and its reliability was
determined through a pilot study. Th