Preferred Language
Articles
/
L3hy6aABuRolNscL1fWX
Fabrication and Enhancement of Organic Photodetectors Based on Iron Phthalocyanine Films
...Show More Authors

Iron–phthalocyanine (FePc) organic photoconductive detector was fabricated using pulsed laser deposition (PLD) technique to work in ultraviolet (UV) and visible regions. The organic semiconductor material (iron phthalocyanine) was deposited on n-type silicon wafer (Si) substrates at different thicknesses (100, 200 and 300) nm. FePc organic photoconductive detector has been improved by two methods: the first is to manufacture the detector on PSi substrates, and the second is by coating the detector with polyamide–nylon polymer to enhance the photoconductivity of the FePc detector. The current–voltage (I–V) characteristics, responsivity, photocurrent gain, response time and the quantum efficiency of the fabricated photoconductive detector were measured. The performance of the fabricated detector was taken under dark and illumination using two types of light sources: UV LED with wavelength (365[Formula: see text]nm), power of (10[Formula: see text]W) and Tungsten lamp with wavelength range between (500–800) nm and the optical power of (250[Formula: see text]W). The photoresponse enhancement was improved by coating the FePc films with 200[Formula: see text]nm of polyamide nylon polymer. This type of coating, which can be considered as a surface treatment, highly increased the photoresponse of the fabricated FePc UV detector. The results show that the responsivity increased four orders of magnitudes more than the responsivity of the uncoated FePc film. The effects of the coated polymers on the responsivity and the response time of the detector were investigated.

Scopus Crossref
Publication Date
Fri Oct 02 2026
Journal Name
Research On Crops
Effect of organic acid, amino acids and nano-fertilizer on growth, yield and nitrate concentration of lettuce plant under two farming systems
...Show More Authors

View Publication Preview PDF
Scopus (4)
Scopus
Publication Date
Tue Dec 31 2024
Journal Name
Anbar Journal Of Agricultural Sciences
EFFECT OF ACIDS AND ORGANIC NUTRIENTS ON CAULIFLOWER GROWTH AND YIELD AND WATER USE EFFICIENCY AND FERTILIZER PRODUCTIVITY OF A MODIFIED NFT HYDROPONICS SYSTEM
...Show More Authors

View Publication
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Thu Jan 01 2015
Journal Name
Journal Of Materials Science And Chemical Engineering
Extraction and Modelling of Oil from Eucalyptus camadulensis by Organic Solvent
...Show More Authors

This work was conducted to study the extraction of eucalyptus oil from natural plants (Eucalyptus camadulensis leaves) by organic solvents. the effects of the main operating parameters were studied; type of solvent (n-hexane and ethanol), time to reach equilibrium, the temperature (45°C to 65°C) for n-hexane and (45°C to 75°C) for ethanol, solvent to solid ratio (5:1 to 8:1 (v/w)), agitation speed (0 to 900 rpm) and the particle size (0.5 to 2.5 cm) of fresh leaves to find the best processing conditions for the achieving maximum oil yield. The concentration of eucalyptus oil in solvent was measured by using UV-spectrophotometer. The results (for n-hexane) showed that the agitation speed of 900 rpm, temperature 65°C with solvent to soli

... Show More
Publication Date
Fri Oct 16 2020
Journal Name
Solid State Technology
Study and Investigation of Transition Rate at Metal–Organic Semiconductor Interfaces
...Show More Authors

In this paper,we focus on the investigated and studied of transition rate in metal/organic semiconductor interface due to quantum postulate and continuum transition theory. A theoretical  model has been used to estimate  the transition rate cross the interface through estimation many parameters such that ;transition energy  ,driving electronic energy U(eV) ,Potential barrier ,electronic coupling  ,semiconductor volume ,density ,metal work function ,electronic affinity and temperature T. The transition energy  is critical facter of charge transfer through the interfaces of metal organic films device and itscontrol of charge injection and transport cross interface. However,the potential at interfa

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 01 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Science
Fabrication and Characterization CdO: In/Si Photovoltaic Solar Cell Prepard By Thermal Evaporation
...Show More Authors

Publication Date
Mon Jan 01 2018
Journal Name
Journal Of Engineering And Applied Sciences
sEffect of Sb doping on CuAlSe2 thin films and their behavior on the preparation CuAlSe2/Si heterojunction solar cells
...Show More Authors

Publication Date
Sun Feb 10 2019
Journal Name
Iraqi Journal Of Physics
Study of the mechanical properties of Iron-Epoxy composite materials
...Show More Authors

Iron-Epoxy composite samples were prepared by added
different weight percentages (0, 5, 10, 15, and 20 wt %) from Iron
particles in the range of (30-40μm) as a particle size. The contents
were mixed carefully, and placed a circular dies with a diameter of
2.5 cm. Different mechanical tests (Shore D Hardness, Tensile
strength, and Impact strength ) were carried out for all samples. The
samples were immersed in water for ten weeks, and after two weeks
the samples were take-out and drying to conducting all mechanical
tests were repeated for all samples. The hardness values increased
when the Iron particle concentration increased while the Impact
strength is not affected by the increasing of Iron particles
c

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Thu Dec 01 2022
Journal Name
Iraqi Journal Of Physics
Study the Effect of Dielectric Barrier Discharge (DBD) Plasma on the Decomposition of Volatile Organic Compounds
...Show More Authors

Recently, research has focused on non-thermal plasma (NTP) technologies as a way to remove volatile organic compounds from the air stream, due to its distinctive qualities, which include a quick reaction at room temperature. In this work, the properties of the plasma generated by the dielectric barrier discharge (DBD) system and by a glass insulator were studied. Plasma was generated at different voltages (3, 4, 6, 7, 8 kV ) with a fixed distance between the electrodes of 5 mm, and a constant argon gas flow rate of (2.5) I/min. DBD plasma emission spectra were recorded for each voltage. The Boltzmann plot method was used to calculate the electron temperature in the plasma ( ), and the Stark expansion method was used to calculate the elec

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Tue Dec 30 2008
Journal Name
Iraqi National Journal Of Nursing Specialties
Assess the Knowledge and Practice of Thalassemic Patient about Complications of Iron Overload and Desferal Compliance
...Show More Authors

Objectives: To assess the knowledge and practice of thalassemic patients about desferal administration and
complications of iron overload.
Methodology: The present study composed of (50) thalssemic patient who are registered in center and was
performed in Ibn Al-Atheer center for congenital anemia for the period from 15/12/2006 to 1/4/2007.
Results: The result of the study showed highly significant difference at (160.05) for knowledge of thalassemic
patients and also appear highly significant difference at (P<O.O5) for practice of thalassemic patients.
Recommendations: The study recommends that there is necessity to increase the knowledge and practice of
thalassemic patient about desferal administration to minimiz

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Dec 01 2010
Journal Name
Baghdad Science Journal
Relation between Body Iron Store and Insulin Resistance in Type 2 Diabetes
...Show More Authors

The clinical impact of interaction between body iron status (serum iron and ferritin) and type 2 diabetes has been investigated in this study. Thirty-six females were enrolled, eighteen type 2 diabetes and eighteen apparently healthy. These two groups were matched for age and body mass index BMI. The eighteen diabetes females were matched for age, BMI, pharmacological treatment (oral hypoglycemic agent), and chronic diabetes complications. The biochemical parameters measured for both groups (control and diabetes patient) were fasting insulin (Io), fasting blood glucose (Go), serum iron and ferritin. A significant increase in all parameters in patients compared to healthy control was noticed. The insulin resistance (IR) which was calculat

... Show More