Titanium dioxide (TiO2) thin films were prepared under different pressures with values (15, 30, 60 and 120) Pa using the DC reactive magnetron homemade system with mixed gases of argon and oxygen in ratio (50:50). The result of X-ray diffraction patterns discovered that the structure of the deposited films was polycrystalline, including the phase of anatase. All the appeared peaks were matched to the planes (101), (004), (105), and (211) of diffracted states. Both the intensities and the number of the appeared peaks are declined according to the increased pressure, and the plane of (101) is be considered the preferential grown plane, it is taking a maximum texture factor. Both the lattice constant and the atomic inter-planer spacing take the highest standard values of the divergence. The transmittance intensity and the Urbach energy were observed to decline with decreasing the total pressure. The thickness of the prepared films was approximately 200 nm. Through the results, it was found that the highest value of the energy gap was at a pressure of 120 Pa.
An approximate solution of the liner system of ntegral cquations fot both fredholm(SFIEs)and Volterra(SIES)types has been derived using taylor series expansion.The solusion is essentailly
Objective(s): This study aimed to evaluate job satisfaction among nurses working at primary health care centers in Samawa City.
Methodology: A Descriptive evolutional study has been carried out during the period from 1 February 2022 to 1 June 2022. A nonprobability (convenience) sample of (200) nurse were selected from different educational level. A questionnaire format is developed for the purpose of fulfilling the objectives of the study. Content validity of the questionnaire and reliability has been determined. Data are analyzed using IBM SPSS version 19 software (2010).
Results: The findings indicate that 52% of nurses are showing high level of job satisfa
... Show MoreFiber Reinforced Polymer (FRP) bars are anisotropic in nature and have high tensile strength in the fiber direction. The use of High-Strength Concrete (HSC) allows for better use of the high-strength properties of FRP bars. The mechanical properties of FRP bars can yield to large crack widths and deflections. As a result, the design of concrete elements reinforced with FRP materials is often governed by the Serviceability Limit States (SLS). This study investigates the short-term serviceability behavior of FRP RC I-beams. Eight RC I-beams reinforced with carbon-FRP (CFRP) and four steel RC I-beams, for comparison purposes, were tested under two-point loading.
Deformations on the concrete and crack widths and spacing are measured and