CdSe alloy has been prepared successfully from its high purity elements. Thin films of this alloy with different thicknesses (300,700)nm have been grown on glass substrates at room temperature under very low pressure (10-5)Torr with rate of deposition (1.7)nm/sec by thermal evaporation technique, after that these thin films have been heat treated under low pressure (10-2)Torr at (473,673)K for one hour. X-ray patterns showed that both CdSe alloy and thin films are polycrystalline and have the hexagonal structure with preferential orientation in the [100] and [002] direction respectively. The optical measurements indicated that CdSe thin films have allowed direct optical energy band gap, and it increases from (1.77- 1.84) eV and from (1.6-1.65)eV with the increase in temperature from (R.T-673)K for thicknesses. (300,700)nm, respectively. The optical constants (refractive index, extinction coefficient and the real, imaginary parts of dielectric constant) were also studied.
Flame atomic absorption spectrophotometer (FAAS) was used in this study to determine the concentrations of heavy metals such as Ca, Fe, Mn, Cd, Co, Cr, Ni, Cu, Pb and Zn in some food additives of Iraq. The order of metal contents in food additives was found to be Ca ˃ Mn ˃ Fe ˃ Cu ˃ Zn ˃ Pb ˃ Cr ˃ Ni ˃ Co ˃ Cd. The concentration level of each metal was compared with that recommended by food agriculture organisation (FAO) and world health organisation (WHO). Calibration curves were linear for all standard solutions of heavy metals in the range starting from 0.02-0.4 mg/kg for Cd to 11-100 mg/kg for Ca. The correlation coefficients values (R2) of calibrations were investigated and ranged from 0.9971 for Cr to 0.9999 for Ca. Th
... Show MoreA simple, low cost and rapid flow injection turbidimetric method was developed and validated for mebeverine hydrochloride (MBH) determination in pharmaceutical preparations. The developed method is based on forming of a white, turbid ion-pair product as a result of a reaction between the MBH and sodium persulfate in a closed flow injection system where the sodium persulfate is used as precipitation reagent. The turbidity of the formed complex was measured at the detection angle of 180° (attenuated detection) using NAG dual&Solo (0-180°) detector which contained dual detections zones (i.e., measuring cells 1 & 2). The increase in the turbidity of the complex was directly proportional to the increase of the MBH concentration
... Show MoreFormation of Au–Ag–Cu ternary alloy nanoparticles (NPs) is of particular interest because this trimetallic system have miscible (Au–Ag and Au–Cu) and immiscible (Ag– Cu) system. So there is a possibility of phase segregation in this ternary system. At this challenge it was present attempts synthetic technique to generate such trimetallic alloy nanoparticles by exploding wire technique. The importance of preparing nanoparticles alloys in distilled water and in this technique makes the possibility of obtaining nanoparticles free of any additional chemical substance and makes it possible to be used in the treatment of cancer or diseases resulting from bacterial or virus with least toxic. In this work, three metals alloys Au-Ag-Cu
... Show MoreA simple, low cost and rapid flow injection turbidimetric method was developed and validated for mebeverine hydrochloride (MBH) determination in pharmaceutical preparations. The developed method is based on forming of a white, turbid ion-pair product as a result of a reaction between the MBH and sodium persulfate in a closed flow injection system where the sodium persulfate is used as precipitation reagent. The turbidity of the formed complex was measured at the detection angle of 180° (attenuated detection) using NAG dual&Solo (0-180°) detector which contained dual detections zones (i.e., measuring cells 1 & 2). The increase in the turbidity of the complex was directly proportional to the increase of the MBH concentration
... Show MoreThe chronic renal disease is a principle common medical dilemma in Iraq. Peripheral arterial disease (PAD) is a prevalent infirmity in the hemodialysis people. The aim of present study was to estimate the prevalence of PAD in subjects with end-stage renal disease (ESRD). This cross-sectional study was done between January 2016 and May 2017 on ESRD subjects regularly attending renal dialysis unit in Al-Kindy teaching hospital in Baghdad, Iraq. PAD was diagnosed on the base of the ankle-brachial index (ABI) measured by using a hand-held Doppler ultrasound. Subjects with ABI ≤0.9 were supposed positive for PAD. A total of 150 ESRD cases were analyzed. The mean age of the subject was 49.52±15 years. Majority of them were males 87(58%). Most
... Show MoreThe research study focuses on the efficient and accurate detection and determination of cobalt ions. The detection method involves the formation of brilliant green aggregates with calcium hexacyanoferrate in the presence of nitric acid. (Nagham-four sources of white snow light-emitting diodes arranged in three rows corresponding to three detectors) (The NAG-4SX3-3D Analyzer is an optical, chemical, electronic, and detection tool that receives a cumulative signal (no amplification is required). The total distance travelled is 760 mm with regard to YZ(mV) - tsec (dmm). It was selected for its precise calculation of the energy transducer profile. The linear range for measuring cobalt (II) ions is 0.05 to 20 mM. For concentrations of 5
... Show MoreSurgical site infections are the second most common type of adverse events occurring in hospitalized patients. Surgical antibiotic prophylaxis refers to the use of preoperative and postoperative antibiotics to decrease the incidence of postoperative wound infections. The objective of this study was to evaluate the antibiotic administration pattern for surgical antibiotic prophylaxis and the adherence to American Society of Health-System Pharmacists surgical antibiotic prophylaxis guideline in Medical City Teaching Hospitals/Baghdad. The medical records of one hundred patients who underwent elective surgical procedures were reviewed. Adherence to the recommendations of American society of health‑system pharmacists guideline was ass
... Show MoreBackground: The aim of this study was to evaluate and compare the apical microleakage around retrograde cavities prepared with ultrasonic technique and filled with (Biodentineâ„¢) Materials and methods: 40 extracted single rooted human permanent maxillary teeth with mature apices were selected. The roots were prepared chemo-mechanically using k-files with crown-down technique and then obturated with lateral condensation gutta-percha technique. Teeth were divided into four main groups according to the cavity preparation method either manual or ultrasonic technique: Group A (n=10): A class I retrograde cavity at root end was prepared with traditional handpeice equipped and placement of Biodentine with manual condensation. Group B (n=10):
... Show More