Preferred Language
Articles
/
KeZRoZ4BmraWrQ4ddGSd
Methylene blue degradation using ZnO:CuO:Al2O3 nanocomposite synthesized by liquid laser ablation
...Show More Authors

Scopus Crossref
View Publication
Publication Date
Mon Feb 18 2019
Journal Name
Iraqi Journal Of Physics
Effect of annealing temperature and laser pulse energy on the optical properties of CuO films prepared by pulsed laser deposition
...Show More Authors

In this work; copper oxide films (CuO) were fabricated by PLD. The films were analyzed by UV-VIS absorption spectra and their thickness by using profilometer. Pulsed Nd:YAG laser was used for prepared CuO thin films under O2 gas environment with varying both pulse energy and annealing temperature. The optical properties of   as-grown film such as optical transmittance spectrum, refractive index and energy gap has been measured experimentally and the effects of laser pulse energy  and annealing temperature on it were studied. An inverse relationship between energy gap and both annealing temperature and pulse energy was observed.

View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Mon Jun 30 2003
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Liquid-Liquid Equilibria of Quaternary Systems Including Sulfonate at 293.15 K
...Show More Authors

View Publication Preview PDF
Publication Date
Thu Feb 07 2019
Journal Name
Iraqi Journal Of Laser
Evaluation of Low Level Laser Therapy using 785 nm Diode Laser on the Enhancement of Chronic Wound Healing
...Show More Authors

Low-intensity laser irradiation has been explored as an alternative, non-invasive method to encourage chronic wounds to heal. This study aimed to evaluate the effects of low level laser therapy (biostimulation) using semiconductor diode laser with wavelength (785 nm) on the enhancement of chronic wound healing. Fifty patients with chronic wounds were selected to be treated with Low Level Laser Therapy. Their ages ranged between 1 to 76 years. The wound sites were distributed in the lower limb, upper limb, trunk , perineum and head (70%,14%,12%,2%,2%, respectively). Application of laser therapy by noncontact method few millimeters from the skin for 15 minutes per one session twice weekly for two months ; ie,16 sessions for each patient. R

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 01 2023
Journal Name
Journal Of Photochemistry And Photobiology A: Chemistry
Improved photocatalytic degradation of methyl violet dye and pathogenic bacteria using g-C3N4 supported phosphotungstic acid heterojunction
...Show More Authors

Scopus (47)
Crossref (41)
Scopus Clarivate Crossref
Publication Date
Mon Jul 10 2023
Journal Name
Sustainability
Solar-Induced Photocatalytic Degradation of Reactive Red and Turquoise Dyes Using a Titanium Oxide/Xanthan Gum Composite
...Show More Authors

The present study explores the solar-induced photocatalytic degradation of reactive red (RR) and reactive turquoise (RT) dyes in a single system using TiO2 immobilized in xanthan gum (TiO2/XG), synthesized using the sol–gel dip-coating technique for direct precipitation. SEM-EDX, XRD, FTIR, and UV–Vis were used to assess the characteristics of the resulting catalyst. Moreover, the effects of different operating parameters, specifically pH, dye concentration, TiO2/XG concentration, H2O2 concentration, and contact time, were also investigated in a batch photocatalytic reactor. The immobilized TiO2/XG catalyst showed a slight adsorption degradation efficiency and then improved the RR and RT dye degradation activity (92.5 and 90.8%

... Show More
View Publication
Scopus (26)
Crossref (23)
Scopus Clarivate Crossref
Publication Date
Thu Dec 31 2020
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
DISPERSIVE LIQUID LIQUID MICRO EXTRACTION SPECTROPHOTOMETRIC DETERMINATION OF TELMESARTAN AND IRBESARTAN IN PHARMACEUTICALS SAMPLES: DISPERSIVE LIQUID LIQUID MICRO EXTRACTION SPECTROPHOTOMETRIC DETERMINATION OF TELMESARTAN AND IRBESARTAN IN PHARMACEUTICALS SAMPLES
...Show More Authors

The current work is characterized by simplicity, accuracy and high sensitivity Dispersive liquid - Liquid Micro Extraction (DLLME). The method was developed to determine Telmesartan (TEL) and Irbesartan (IRB) in the standard and pharmaceutical composition. Telmesartan and Irbesartan are separated prior to treatment with Eriochrom black T as a reagent and formation ion pair reaction dye. The analytical results of DLLME method for linearity range (0.2- 6.0) mg /L for both drugs, molar absorptivity were (1.67 × 105-    5.6 × 105) L/ mole. cm, limit of detection were (0.0242and0.0238), Limit of quantification were (0.0821and0.0711), the Distribution coefficient were

... Show More
View Publication Preview PDF
Publication Date
Mon Feb 18 2019
Journal Name
Iraqi Journal Of Physics
Different methods for characterizing surface roughness using laser speckle technique
...Show More Authors

In this work, results from an optical technique (laser speckle technique) for measuring surface roughness was done by using statistical properties of speckle pattern from the point of view of computer image texture analysis. Four calibration relationships were used to cover wide range of measurement with the same laser speckle technique. The first one is based on intensity contrast of the speckle, the second is based on analysis of speckle binary image,  the third is on size of speckle pattern spot, and the latest one is based on characterization of the energy feature of the gray level co-occurrence matrices for the speckle pattern. By these calibration relationships surface roughness of an object surface can be evaluated within the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jan 22 2020
Journal Name
Iraqi Journal Of Laser
Stress Urinary Incontinence Treatment Using Vaginal Fractional CO2 Laser (10600nm)
...Show More Authors

Stress urinary incontinence (SUI) is involuntary urine leakage during activities that increase abdominal pressure such as coughing, sneezing and lifting of heavy weights. This is a very common disorder among women with history of multiple vaginal deliveries with an obstructed labor. SUI is considered one of the most distressing problems, especially for younger women, with severe quality of life implications, it caused by the loss of urethral support, usually as a consequence of the supporting structural muscles in the pelvis.

Objective: To prove and demonstrate the effect of a fractional CO2 micro-ablative laser (10600nm) in intra vaginal therapy for treating SUI and achieve a clinical improvement of t

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 01 2009
Journal Name
Al-khwarizmi Engineering Journal
Breast Tumor Diagnosis Using Diode Laser in Near Infrared Region
...Show More Authors

In the last years, new non-invasively laser methods were used to detect breast tumors for pre- and postmenopausal females. The methods based on using laser radiation are safer than the other daily used methods for breast tumor detection like X-ray mammography, CT-scanner, and nuclear medicine.  

      One of these new methods is called FDPM (Frequency Domain Photon Migration). It is based on the modulation of laser beam by variable frequency sinusoidal waves. The modulated laser radiations illuminate the breast tissue and received from opposite side.

      In this paper the amplitude and the phase shift of the received signal were calculated according to the orig

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 11 2003
Journal Name
Iraqi Journal Of Laser
Microdrop Size Measurement in a Mixing Unit Using Laser Technique
...Show More Authors

One of the troublesome duties in chemical industrial units is determining the instantaneous drop size distribution, which is created between two immiscible liquids within such units. In this work a complete system for measuring instantaneous droplet size is constructed. It consists of laser detection system (1mW He-Ne laser), drop generation system (turbine mixer unit), and microphotography system. Two immiscible liquids, water and kerosene were mixed together with different low volume fractions (0.0025, 0.02) of kerosene (as a dispersed phase) in water (as a continuous phase). The experiments were carried out at different rotational speed (1180- 2090 r.p.m) of the turbine mixer. The Sauter mean diameter of the drops was determined by la

... Show More
View Publication Preview PDF