The experiment was conducted in field of the University of Baghdad, Jadryia region, Baghdad to measure vibration and performance efficiency of grass mower (machine cutting grass). Vibration in three axes are longitudinal X , lateral Y and vertical Z in four places of mower machine during cutting grass and Practical Productivity, Efficiency and Fuel Consumption measured in this experiment . Factorial design (3 x 2) used, mower speeds included 1.9 3.6 and 6.4 km/hr and engine load included idling and full load according to randomized complete design were used in this experiment. Least Significant Design (LSD) 0.05 was used to compare the mean of treatment. Result were showed that the mower speed 6.4 km/hr recorded high productivity (0.6557 ha/hr), low fuel consumption (1.62 l/ha), least efficiency ( 83.97 %), vibration values for three axes X,Y and Z (8.28, 7.85) and (5.35 m/sec²) for mower seat, (6.25, 7.05) and (4.80 m/sec²) for steering wheel and (14.78, 13.8) and (11.58 m/sec²) for mower chasses and (21.45, 20.05) and (16.15 m/sec²) for cover blades. Engine full load recorded high productivity (0.4080 ha/hr), efficiency (84.47%), and high vibration values for three axes X, Y and Z were (5.46, 5,03) and (3.56 m/sec²) for mower seat , (4.56, 5.30) and (3.36 m/sec²) for steering wheel, (13.30, 12.32) and (10.93 m/sec²) for mower chasses and (18.13, 17.03) and (13.83 m/sec²) for cover blades,Then these result a cross legislated permissible vibration exposure limits in the world.
Concrete pavements are essential to modern infrastructure, but their low tensile and flexural strengths can cause cracking and shrinkage. This study evaluates fiber reinforcement with steel and carbon fibers in various combinations to improve rigid pavement performance. Six concrete mixes were tested: a control mix with no fiber, a mix with 1% steel fiber (SF1%), a mix with 1% carbon fiber (CF1%), and three hybrid mixes with 1% fiber content: 0.75% steel /0.25% carbon fiber (SF0.75CF0.25), 0.25% steel /0.75% carbon fiber (SF0.25CF0.75), and 0.5% steel /0.5% carbon fiber ((SF0.5CF0.5). Laboratory experiments including compressive, flexural, and splitting tensile strength tests were conducted at 7, 28, and 90 days, while Finite Element Analys
... Show MoreThe optimum design is characterized by structural concrete components that can sustain loads well beyond the yielding stage. This is often accomplished by a fulfilled ductility index, which is greatly influenced by the arrangement of the shear reinforcement. The current study investigates the impact of the shear reinforcement arrangement on the structural response of the deep beams using a variety of parameters, including the type of shear reinforcement, the number of lacing bars, and the lacing arrangement pattern. It was found that lacing reinforcement, as opposed to vertical stirrups, enhanced the overall structural response of deep beams, as evidenced by test results showing increases in ultimate loads, yielding, and cracking of
... Show MoreExperimental tests were conducted to study the behavior of skirted foundations rested on dry medium sandy soil subjected to vertical and inclined loads. To achieve this goal, a small-scale physical model was designed and performed which contained an aluminum circular footing (100 mm) in diameter and (10 mm) in thickness and skirts with different heights, local medium poorly graded dry sand is placed in a steel soil container (2 mm) thick with internal dimensions (1000 mm x 1000 mm in cross section and 800 mm in height). The main objective of this study was to evaluate the response of skirt attached to the foundation at different skirt (L/D) ratios (0.0, 0.5, 1.0 and 1.5) and is subjected to point load at different angles of inclinat
... Show MoreThe sustainable development according to the United Nation, listed firms throughout globally now routinely provide sustainability data. However, there is not enough information on Sustainability Performance Quality (SPQ) in the majority of emerging economies, including Malaysia. This study looks at how the SPQ of the top 100 Malaysian-listed businesses is affected by factors as connected with corporate governance (e.g., board meeting, board size, and board ethnic diversity). Utilizing 500 firm-year data, a longitudinal sample of 500 nonfinancial firms on the Bursa Malaysia for 2015-2019 is employed in this study. The findings from the analysis using the panel regression demonstrated that: ethnic diversity and board siz
... Show MoreThis paper proposes a novel finite-time generalized proportional integral observer (FTGPIO) based a sliding mode control (SMC) scheme for the tracking control problem of high order uncertain systems subject to fast time-varying disturbances. For this purpose, the construction of the controller consists of two consecutive steps. First, the novel FTGPIO is designed to observe unmeasurable plant dynamics states and disturbance with its higher time derivatives in finite time rather than infinite time as in the standard GPIO. In the FTGPO estimator, the finite time convergence rate of estimations is well achieved, whereas the convergence rate of estimations by classical GPIO is asymptotic and slow. Secondly, on the basis of the finite and fast e
... Show More This paper describes the application of consensus optimization for Wireless Sensor Network (WSN) system. Consensus algorithm is usually conducted within a certain number of iterations for a given graph topology. Nevertheless, the best Number of Iterations (NOI) to reach consensus is varied in accordance with any change in number of nodes or other parameters of . graph topology. As a result, a time consuming trial and error procedure will necessary be applied
to obtain best NOI. The implementation of an intellig ent optimization can effectively help to get the optimal NOI. The performance of the consensus algorithm has considerably been improved by the inclusion of Particle Swarm Optimization (PSO). As a case s
The thermal and electrical performance of different designs of air based hybrid photovoltaic/thermal collectors is investigated experimentally and theoretically. The circulating air is used to cool PV panels and to collect the absorbed energy to improve their performance. Four different collectors have been designed, manufactured and instrumented namely; double PV panels without cooling (model I), single duct double pass collector (model II), double duct single pass (model III), and single duct single pass (model IV) . Each collector consists of: channel duct, glass cover, axial fan to circulate air and two PV panel in parallel connection. The temperature of the upper and
... Show More