Continuous turbidimetric analysis (CTA) for a distinctive analytical application by employing a homemade analyser (NAG Dual & Solo 0-180°) which contained two consecutive detection zones (measuring cells 1 & 2) is described. The analyser works based on light-emitting diodes as a light source and a set of solar cells as a light detector for turbidity measurements without needing further fibres or lenses. Formation of a turbid precipitated product with yellow colour due to the reaction between the warfarin and the precipitation reagent (Potassium dichromate) is what the developed method is based on. The CTA method was applied to determine the warfarin in pure form and pharmaceutical formulations in the concentration range from 2.0-16& 0.7-16 mmol/L with 0.58 and 0.55 mmol/L of the limit of detections. The correlation coefficients (r) of the developed method were 0.9977 and 0.9981 for cell 1 and 2 respectively. For validation of proposed method, the ICH guidelines were followed. The developed method was successfully applied for the determination of Warfarin in pure and pharmaceutical preparations. In addition, the method can be considered as a quality control method and conveniently used for routine analysis in laboratories since the method permits quantitatively determination of 60 samples/h.
Abstract :
The Aims of this research is to describe the concept of risk, its type and method of measurement, and to clarify the impact of these risks on the expected cash flow statement and the preparation of the target cash flow statement that takes these risks into consideration. Because the local economic environment is exposed to many risks, Therefore, this list will be predictive, which will help the economic unit to make administrative decisions, especially decisions related to operational, investment and financing activities. Therefore, the research problem is based on the fact that most of the local economic units are the list of flows According to the actual basis and not according to the discretionary basis (bud
... Show MoreBN Rashid
This paper presents an enhancement technique for tracking and regulating the blood glucose level for diabetic patients using an intelligent auto-tuning Proportional-Integral-Derivative PID controller. The proposed controller aims to generate the best insulin control action responsible for regulating the blood glucose level precisely, accurately, and quickly. The tuning control algorithm used the Dolphin Echolocation Optimization (DEO) algorithm for obtaining the near-optimal PID controller parameters with a proposed time domain specification performance index. The MATLAB simulation results for three different patients showed that the effectiveness and the robustness of the proposed control algorithm in terms of fast gene
... Show MoreIn this work, a fiber-optic biomedical sensor was manufactured to detect hemoglobin percentages in the blood. SPR-based coreless optical fibers were developed and implemented using single and multiple optical fibers. It was also used to calculate refractive indices and concentrations of hemoglobin in blood samples. An optical fiber, with a thickness of 40 nanometers, was deposited on gold metal for the sensing area to increase the sensitivity of the sensor. The optical fiber used in this work has a diameter of 125μm, no core, and is made up of a pure silica glass rod and an acrylate coating. The length of the fiber was 4cm removed buffer and the splicing process was done. It is found in practice that when the sensitive refractive i
... Show MoreFuture generations of wireless communications systems are expected to evolve toward allowing massive ubiquitous connectivity and achieving ultra-reliable and low-latency communications (URLLC) with extremely high data rates. Massive multiple-input multiple-output (m-MIMO) is a crucial transmission technique to fulfill the demands of high data rates in the upcoming wireless systems. However, obtaining a downlink (DL) training sequence (TS) that is feasible for fast channel estimation, i.e., meeting the low-latency communications required by future generations of wireless systems, in m-MIMO with frequency-division-duplex (FDD) when users have different channel correlations is very challenging. Therefore, a low-complexity solution for
... Show MoreWhen embankment is constructed on very soft soil, special construction methods are adopted. One of the techniques is a piled embankment. Piled (stone columns) embankments provide an economic and effective solution to the problem of constructing embankments over soft soils. This method can reduce settlements, construction time and cost. Stone columns provide an effective improvement method for soft soils under light structures such as rail or road embankments. The present work investigates the behavior of the embankment models resting on soft soil reinforced with stone columns. Model tests were performed with different spacing distances between stone columns and two lengths to diameter ratios of the stone columns, in addition to different
... Show MoreThis research seeks through the adoption of two basic variables, where he considered the actuarial experience as an independent variable, while the process of accepting the risk and dimensions related to it is a dependent variable, the research was adopted to present the data achieved by the company during the life insurance business during the adoption of actuarial experience at the beginning of its work where Adoption of the historical method in the analysis of those data to prove the researcher's opinion, through the analysis of data (5 years) for the first period, which extends between (1975-1979), the period during which the company adopted the actuarial experience at the time, also taken data for the same dimensions related to the
... Show MoreIn this research, the X-ray diffraction pattern was used, which was obtained experimentally after preparation of barium oxide powder. A program was used to analyze the X-ray diffraction lines of barium oxide nanoparticles, and then the particle size was calculated by using the Williamson-Hall method, where it was found that the value of the particle size is 25.356 nm. Also, the dislocation density was calculated, which is equal to1.555 x1015 (lines/nm2), and the value of the unit cell number was also calculated, as it is equal to 23831.
APDBN Rashid, Review of International Geographical Education Online (RIGEO), 2021