The zirconia ceramic restoration (ZCR) is used as substitutes for the metal-ceramic restoration. Clinical studies demonstrating of ZCRs showed a high fracture incidence of veneering layer than metal-ceramic restorations. This attributed to the low bond strength of zirconia to veneering ceramic as a result of lacking of glass content in its matrix. Surface treatment was proposed to improve the bonding strength between zirconia and veneering ceramic. Several studies revealed that some treatment such as airborne particle abrasion (APA) is responsible for generating chipping of veneering ceramic. The study aimed to develop a new zirconia coatings to increase bonding strength between zirconia substrate and veneering porcelain. Three groups of 150 zirconia specimens (discs, rods and crowns) were divided according to the type of surface treatments; Group M1 designated unsintered zirconia specimens coated with a mixture of glaze porcelain powder and partially-sintered zirconia powder prepared at 1100 °C with two particle sizes; A (26 ± 0.3 μm) and size B (47 ± 0.5 μm), group M2 was coated with mixture of ceramic liner paste and same selected particle sizes of partially-sintered zirconia powders. The coated groups (M1 and M2) subdivided according to powder sizes into M1A, M1B, M2A and M2B. APA group (as control) of sintered zirconia specimens abraded with 50 μm aluminium oxide powder. Surface area roughness (Sa) was measured by surface texture analyser. Surface morphology and elemental composition were analysed by scanning electron microscope (SEM). Crystallographic phases were identified by X-ray diffraction (XRD). The coefficient of thermal expansion (CTE) was assessed by a thermomechanical analyser. For shear bond strength (SBS) test was evaluated by a universal testing machine (UTM). The fracture strength (FS) test prepared and measured by Cercon CAD/CAM system and UTM. Fractographic analysis for SBS and FS were examined by a stereomicroscope and SEM. For each test and measurement, 10 specimens were used per group. Finite element analysis (FEA) was used to simulate and predict the iv stress distributions of the static oblique load in coated and non-coated zirconia crown models. The collected data were analysed by one-way ANOVA and Tukey HSD test at (P<0.05). Surface roughness results showed significant differences among all groups (P<0.000). The M1B group exhibited a higher Sa value (10.33 ± 0.59 μm) among the tested groups. XRD analysis showed tetragonal and monoclinic phases in the control group while only tetragonal was detected in the coated groups. The SBS values for coated groups were higher than the control group. The M1B group showed higher and significant differences in SBS value (37.54 ± 4.38 MPa) among other tested groups (P<0.05). The FS test indicated that coated M1B group (647.92 ± 97.33 N) higher than the other groups (P<0.00). FEA showed the coated crown models have lower stress level than the non-coated model. The new coating (M1B) by airbrush spray technique considered as an alternative way to APA treatment to improve the bond strength of zirconia substrate to veneering ceramic and indicating as an applicable surface treatment for improving the clinical performance of the coated ZCR.
Background: In this study we evaluate the effect of plasma treatment (oxygen and argon) gas in two different exposure times on the surface of heat cure and light cure acrylic resin. Materials and method: 100 specimens of heat cure and light cure acrylic resin were fabricated. The measurements of the samples were (75mm, 25mm and 4.5mm) length, width and depth respectively with stopper of 3mm depth. Two types of gas used oxygen and argon in (5,10) min by using (DC-glow discharge plasma device) then we apply cold cure soft lining material, with the help of Instron machine we test the shear stress value. Results: A highly significant effect after argon and oxygen gases treatment in both 5 and 10 min exposure times on shear bond strength to soft
... Show More
We report a method of converting non-conductive plastic surfaces into conductive by plating either copper electroless or copper electroplating -carbon black containing bending Agent onto Perspex plastics . Various approaches have been studied in order to comparing properties of the plated copper for two methods such as scanning electron microscopy (SEM),thickness, roughness, porosity, tensile Strength and elongation. The results show that the surface of electroplating was uniform, compact, and continuous and it had an obvious metallic sheen, while the surface of plated copper for electroless for it had many pores. Also observed that the coating was composed of small cells. Thes
... Show MoreBackground: The aim of this national oral health survey was to determine the prevalence of malocclusions due to some anomalies in the dentition among the 13 years old Kurdish students in sulaimani intermediate school. Materials and methods: The total sample was 950 (455 males and 495 females) which assessed by diagnostic set and special instrument. The clinical examination was mainly based on the definitions of Björk et al. Some variables were recorded as present or absent sometimes denoting the tooth or the teeth involved in malocclusion and their distribution according to the whole sample. Results: The results showed that 1)The most common extracted tooth was the mandibular first molar (2.9%). 2) At this age group the most common partial
... Show MoreBackground: Osteoporosis is a systemic skeletal disorder affects general health in addition to effect on salivary physical and chemical composition which lead to an adverse effect on oral health status. This study was conducted to evaluate the concentration of glycoprotein (osteonectin) in saliva and its effect on dental caries in relation to salivary flow rate and viscosity among osteoporotic women and compared to control group. Materials and Methods: The total sample composed of 60 females aged 60-65 years attending Al-Yarmook Teaching Hospital, 30 females diagnosed with osteoporosis by measuring bone density at the spine and femur with a dual-energy X-ray absorptiometry at T-score of >2.5, and 30 women without osteoporosis with T-score o
... Show MoreBackground: One of the recommended methods for reducing aerosol contamination during the daily regular usage of high-speed turbine and ultrasonic scaling is the use of preprocedural mouth rinse. Several agents have been investigated as a preprocedural mouth rinse. Chlorhexidine significantly reduce the viable microbial content of aerosol when used as a preprocedural rinse. Studies have shown that cetylpridinum chloride (CPC) mouthwash is equally effective as chlorhexidine in reducing plaque and gingivitis. This study compared the effect of 0.07% CPC to 0.2% chlorhexidine gluconate (CHX) as preprocedural mouth rinses in reducing the aerosol contamination by high-speed turbine. Materials and Methods: 36 patients were divided into three gro
... Show MoreBackground: Recently, Poly propylene fibers with and without plasma treatment have been used to reinforce heat cure denture base acrylic but, so far some of properties like tensile strength , wettability and wear resistance not evaluated yet, the aim of the study is to clarify the influence of incorporation of treated and untreated fibers on these properties. Materials and methods: Twenty one specimens were fabricated for every tested property(tensile strength, wear resistance and wettability) that classified into three groups(control, untreated poly propylene fibers reinforced specimens and Oxygen plasma treated group)and for each test sevens amples were used(n=7). Tensile strength was tested using Instron universal testing machine, wear
... Show MoreChoosing an appropriate impression material is a challenge for many dentists, yet an essential component to provide an excellent clinical outcome and improve productivity and profit. The purpose of present study was to compare wettability, tear strength and dimensional accuracy of three elastomeric impression materials, with the same consistencies (light-body). Three commercially available light body consistency and regular set 3M ESPE Express polyvinylsiloxane (PVS), 3M ESPE Permadyne polyether (PE), and Identium (ID), impression materials were comparedTear strength test, contact angle test and linear dimensional accuracy were evaluated for three elastic impression material. Among the three experimental groups PE impression materia
... Show MoreBackground: The association between diabetes and inflammatory dental diseases had been studied extensively for more than 50 years. A large evidence base suggests that diabetes is associated with an increased prevalence, extent and severity of gingivitis and periodontitis and loss of teeth. Many patients do not aware that they are diabetic.Objectives:The aim of the current study was to assess a fast, non-invasive, safe procedure to screen for diabetes and its severity in dental clinics and to assess the change in blood glucose level before and after tooth extraction during periodontalResults: there were no significant differences between the blood samples collected before tooth extraction from finger puncture method (FPB) and the gingival
... Show MoreBackground:Periodontal diseases and dental caries are the most common oral diseases, but they can be adequately prevented by adopting a specific health behavior and plaque control.The study was carried out to determine and compare oral health status; it included both caries experience, gingival health and oral hygiene behavior betweenfirst and fifth yearsof Al-Mustansiriyahdental students. Materials and methods: Total sample of the study consisted of 50 students at first year (25 males, 25 females)and 60 students at fifth year (30 males, 30 females). Plaque andgingival indices,dental caries indices (DMFS and DMFT) wererecorded to evaluateoral health status for each student. Further questionnaires were given to evaluate different oral hyg
... Show More