Preferred Language
Articles
/
JxZPyIoBVTCNdQwCqqUA
Silver oxide-zeolite for removal of an emerging contaminant by simultaneous adsorption-photocatalytic degradation under simulated sunlight irradiation
...Show More Authors

Scopus Clarivate Crossref
View Publication
Publication Date
Tue Jun 02 2020
Journal Name
International Journal Of Pharmaceutical Research
Synthesis, characterization and Study Bioactivity of Silver Nanocomposites
...Show More Authors

The work include synthesis of nanocomposites (X / S / Ag) based on blend from Xanthan gum / sodium alginate polymers (X / S) with different loading of synthesized silver nanoparticales (0.01, 0.03 and 0.05 wt%) were added to the blend. The silver nanoparticles were prepared by reduction method and were characterized and analyzed using X-ray diffraction (XRD) and Atomic force microscope (AFM). XRD study showed the presence nanoparticle of silver with crystalline nature and face-centered cubic (FCC) structure and an average size of nanoparticles ranging from 32 to 37 nm. The surface study was performed using AFM which showed a fairly uniform shape to the nanocomposites and a spherical nature for the silver nanoparticles. The nanocomposite exh

... Show More
Scopus (1)
Scopus Crossref
Publication Date
Thu Feb 28 2019
Journal Name
Journal Of Engineering
Activated Bentonite for Removal Nickle and Vanadium from Petroleum Distillates
...Show More Authors

The present work is to investigate the feasibility of removal vanadium (V) and nickel (Ni) from Iraqi heavy gas oil using activated bentonite. Different operating parameters such as the degree of bentonite activation, activated bentonite loading, and operating time was investigated on the effect of heavy metal removal efficiency. Experimental results of adsorption test show that Langmuir isotherm predicts well the experimental data and the maximum bentonite uptake of vanadium was 30 mg/g. The bentonite activated with 50 wt% H2SO4 shows a (75%) removal for both Ni and V. Results indicated that within approximately 5 hrs, the vanadium removal efficiencies were 33, 45, and 60% at vanadium loadings of 1

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Jan 01 2025
Journal Name
Biomaterials Science
Single-atom silver-borophene hybrid hydrogels for electrically stimulated wound healing: a multifunctional antibacterial platform
...Show More Authors

View Publication
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Fri Dec 01 2023
Journal Name
Baghdad Science Journal
Simultaneous Determination of Binary Mixture of Estradiol and Progesterone Using Different Spectrophotometric Methods
...Show More Authors

Four rapid, accurate and very simple derivative spectrophotometric techniques were developed for the quantitative determination of binary mixtures of estradiol (E2) and progesterone (PRG) formulated as a capsule. Method I is the first derivative zero-crossing technique, derivative amplitudes were detected at the zero-crossing wavelength of 239.27 and 292.51 nm for the quantification of estradiol and 249.19 nm for Progesterone. Method II is ratio subtraction, progesterone was determined at λmax 240 nm after subtraction of interference exerted by estradiol. Method III is modified amplitude subtraction, which was established using derivative spectroscopy and mathematical manipulations. Method IIII is the absorbance ratio technique, absorba

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Nov 14 2018
Journal Name
Journal Of Engineering And Applied Sciences
DEMONSTRATE OF MAGNETIC FIELD EFFECT ON THE CAPABILITY OF ADSORPTION PROCESS IN THE REMOVAL OF AZO DYE FROM THE AQUEOUS SOLUTIONS ON CALCINED IRAQI BENTONITE CLAY MINERAL VIA COLUM
...Show More Authors

Publication Date
Wed Jan 01 2025
Journal Name
Aip Conference Proceedings
Determination of cefotaxime-sodium at nanoscale level by a microflow injection cell via measuring turbidity using five irradiation sources (WSLEDs) with a single solar cell
...Show More Authors

This work presents a completely new develop an analyzer, named NAG-5SX1-1D-SSP, that is simple, accurate, reproducible, and affordable for the determination of cefotaxime sodium (CFS) in both pure and pharmaceutical drugs. The analyzer was designed according to flow injection analysis, and conducted to turbidimetric measurements. Ammonium cerium nitrate was utilized as a precipitating agent. After optimizing the conditions, the analysis system exhibited a linear range of 0.008-27 mmol. L-1 (n=29), with a limit of detection of 439.3 ng/sample, a limit of quantification of 0.4805 mg/sample, and a correlation coefficient of 0.9988. The repeatability of the responses was assessed by performing six successive injections of CFS at concentra

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Thu Oct 01 2020
Journal Name
International Journal Of Interdisciplinary Telecommunications And Networking
Simulated Performance of TFRC, DCCP, SCTP, and UDP Protocols Over Wired Networks
...Show More Authors

Multimedia applications impose different QoS requirements (e.g., bounded end-to-end delay and jitter) and need an enhanced transport layer protocol that should handle packet loss, minimize errors, manage network congestion, and transmit efficiently. Across an IP network, the transport layer protocol provides data transmission and affects the QoS provided to the application on hand. The most common transport layer protocols used by Internet applications are TCP and UDP. There are also advanced transport layer protocols such as DCCP and TFRC. The authors evaluated the performance of UDP, DCCP, SCTP, and TFRC over wired networks for three traffic flows: data transmission, video streaming, and voice over IP. The evaluation criteria were thro

... Show More
View Publication
Crossref (2)
Clarivate Crossref
Publication Date
Wed Jul 01 2015
Journal Name
Journal Of Engineering
A comparative Isothermal and Kinetic Study of the Adsorption of Lead (II) from Solution by Activated Carbon and Bentonite
...Show More Authors

This work is aiming to study and compare the removal of lead (II) from simulated wastewater by activated carbon and bentonite as adsorbents with particle size of 0.32-0.5 mm. A mathematical model was applied to describe the mass transfer kinetic.

The batch experiments were carried out to determine the adsorption isotherm constants for each adsorbent, and five isotherm models were tested to choose the best fit model for the experimental data. The pore, surface diffusion coefficients and mass transfer coefficient were found by fitting the experimental data to a theoretical model. Partial differential equations were used to describe the adsorption in the bulk and solid phases. These equations were simplified and the

... Show More
View Publication Preview PDF
Publication Date
Mon Feb 18 2019
Journal Name
Iraqi Journal Of Physics
Derivative of an image that corrupted by additive noise
...Show More Authors

In this paper the behavior of the quality of the gradient that implemented on an image as a function of noise error is presented. The cross correlation coefficient (ccc) between the derivative of the original image before and after introducing noise error shows dramatic decline compared with the corresponding images before taking derivatives. Mathematical equations have been constructed to control the relation between (ccc) and the noise parameter.

View Publication Preview PDF
Crossref
Publication Date
Mon Jun 30 2008
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Effect of Temperature and pH on the Removal / Recovery of ZN++ from Solution by Chemical Coagulation
...Show More Authors

This work was conducted to study the treatment of industrial waste water, and more particularly those in the General Company of Electrical Industries.This waste water, has zinc ion with maximum concentration in solution of 90 ppm.
The reuse of such effluent can be made possible via appropriate treatments, such as chemical coagulation, Na2S is used as coagulant.
The parameters that influenced the waste water treatment are: temperature, pH, dose of coagulant and settling time.
It was found that the best condition for zinc removal, within the range of operation used ,were a temperature of 20C a pH value of 13 , a coagulant dose of 15 g Na2S /400ml solution and a settling time of 7 days. Under these conditions the zinc concentrat

... Show More
View Publication Preview PDF