Aim: The present study aims to improve the poor water solubility of zaltoprofen which is a non-steroidal anti-inflammatory drug (NSAIDs) with a potent analgesic effect using solid dispersion then formulate it as a hollow type suppository to be more convenient for geriatric patients. Materials and Method: Zaltoprofen solid dispersions were prepared by solvent evaporation technique in different zaltoprofen: Soluplus® ratios. Results: Among the formulations tested, zaltoprofen solid dispersion preparation using 1:5 (zaltoprofen: Soluplus®) ratio showed the highest solubility and selected for further investigation. Solid dispersion characterization was evaluated by differential scanning calorimetry (DSC), X-ray diffraction study (XRD) and Fourier transformation infrared spectroscopy (FTIR). DSC and XRD analysis showed a complete transformation of zaltoprofen in the solid dispersion from a crystalline state to amorphous state. The selected zaltoprofen solid dispersion was further incorporated into hollow type suppositories using witepsol H 35 as a suppositories base. The hollow type suppositories were evaluated for hardness test (breaking strength), melting time, softening time and in vitro drug dissolution rate. Formula F8 containing zaltoprofen solid dispersion in the whole of hollow type suppository showed the shortest and significantly the highest dissolution rate profile (100% within 15 min) compared to other hollow type suppository formulas prepared that contain zaltoprofen powder in its whole. Conclusion: It is concluded that the development of zaltoprofen solid dispersions using Soluplus® as hollow-type suppositories could be used as a promising approach for improving the solubility of poorly water-soluble drugs
Abstract
Objective(s): To determine the interventional program effectiveness on nurses' practices concerning diet instructions for orthopedic patients treated by internal fixation devices.
Methodology: A quantitative approach using prexperimental design is conducted to determine the effectiveness of an interventional program on nurses’ practices regarding orthopedic patients diet instruction and teaching after internal fixation implemented. The study has started from 1st of April 2022 and ended on 15th of December, 2022. The conduction of the study in Misan governorate / Al-Zaharawy surgical hospital. A non-probability, purpo
... Show MoreBACKGROUND: Transverse fractures of the patella are important fractures with a wide variety of subtypes, the common incidence in the age group of 20–50 years. Surgical interference aims to achieve a perfect alignment of the joint surface, in addition to rigid fixation of the fracture for early re-habitation and early movement to retain the extensor mechanism of the knee joint. AIM: The aim of this study was to compare the radiological and functional outcomes of the displaced transverse patella fracture in adult patients treated by ORIF using tension band wiring versus cannulated screws with wiring. METHODS: A prospective analytic comparative study was conducted in Al-Kindy Teaching Hospital/Baghdad/Iraq for 18 months from Apr
... Show MoreThis study aimed at evaluating the torsional capacity of reinforced concrete (RC) beams externally wrapped with fiber reinforced polymer (FRP) materials. An analytical model was described and used as a new computational procedure based on the softened truss model (STM) to predict the torsional behavior of RC beams strengthened with FRP. The proposed analytical model was validated with the existing experimental data for rectangular sections strengthened with FRP materials and considering torque-twist relationship and crack pattern at failure. The confined concrete behavior, in the case of FRP wrapping, was considered in the constitutive laws of concrete in the model. Then, an efficient algorithm was developed in MATLAB environment t
... Show MoreWe studied the effect of certain environmental conditions for removing heavy metal elements from contaminated aqueous solutions (Cd, Cu, Pb, Fe, Zn, Ni, Cr) using the bacterium Bacillus subtilis to appoint the optimal conditions for removal ,The best optimum temperature range for two isolate was 30-35○C while the hydrogen number for the maximum mineral removal range was 6-7. The best primary mineral removal was 100 mg/L, while the maximum removal for all minerals was obtained after 6 hrs of Cu element time and the maximum removal efficiency was obtained after 24 hrs of Cu element. The results have proved that the best aeration for maximum removal was obtained at rotation speed of 150 rpm/minute. Inoculums of 5ml/100ml which contained 1
... Show MoreElectrochemical oxidation in the presence of sodium chloride used for removal of phenol and any other organic by products formed during the electrolysis by using MnO2/graphite electrode. The performance of the electrode was evaluated in terms fraction of phenol and the formed organic by products removed during the electrolysis process. The results showed that the electrochemical oxidation process was very effective in the removal of phenol and the other organics, where the removal percentage of phenol was 97.33%, and the final value of TOC was 6.985 ppm after 4 hours and by using a speed of rotation of the MnO2 electrode equal to 200 rpm.
Abstract:
We can notice cluster data in social, health and behavioral sciences, so this type of data have a link between its observations and we can express these clusters through the relationship between measurements on units within the same group.
In this research, I estimate the reliability function of cluster function by using the seemingly unrelate
... Show MoreBackground: Marginal adaptation is critical for long – term success of crown and bridge restoration. Computer aided design / computer aided manufacture (CAD/ CAM) system is gaining more importance in the fabrication of dental restoration. Objective: The aim of this study is to evaluate the effect of crystallization firing on the vertical marginal gap of IPS. emax CAD crowns which fabricated with two different CAD/CAM systems .Materials and Methods: Twenty IPS e.max CAD crowns were fabricated. We had two major groups (A, B) (10 crowns for each group) according to the CAD/CAM system being used: Group A: fabricated with Imes - Icore CAD/CAM system; Group B: fabricated with In Lab Sirona CAD/CAM system. Each group was subdivided into two s
... Show More