A new, Simple, sensitive and accurate spectrophotometric methods have been developed for the determination of sulfamethoxazole (SMZ) drug in pure and dosage forms. This method based on the reaction of sulfamethoxazole (SMZ) with 1,2-napthoquinone-4-sulphonic acid (NQS) to form Nalkylamono naphthoquinone by replacement of the sulphonate group of the naphthoquinone sulphonic acid by an amino group. The colored chromogen shows absorption maximum at 460 nm. The optimum conditions of condensation reaction forms were investigated by (1) univariable method, by optimizing the effect of experimental variables (different bases, reagent concentration, borax concentration and reaction time), (2) central composite design (CCD) including the effect of three experimental factors (reagent concentration, borax concentration, and reaction time). The linearity ranges of sulfamethoxazole are (5-50) µg.mL-1 at 460 nm with molar absorptivity (6.7878×104- 7.0918×104) L.mol-1.cm-1, Sandell's sensitivity index (0.3755- 0.3571) μg.cm-2 and detection limit of (0.3755– 0.3594) µg.mL-1 for each procedure respectively. The results showed there are no interferences of excipients on the determination of the drug. The proposed method has been successfully applied for the determination of sulfamethoxazole in pure and pharmaceutical preparations.
The current study included measuring the percent of protein in the extract of nematode Ascaridia galli that infect chickens, it was 1.157% and equivalent to 11.570 mg /L., as well as the amino acid analysis in the nematode A.galli by using a high-performance liquid chromatography technique (HPLC), as was detect five types for amino acids in this extract Leucine, Threonin, Serine, Methionine and Valine as the amount of these amino acids in the extract was as follows 132.973, 26.994, 10.453, 2.243 and 1.888 mg /L., respectively, and other amino acids which Glutamic, Histidine and Tyrosin did not exist in the nematode A.galli.
Generally, statistical methods are used in various fields of science, especially in the research field, in which Statistical analysis is carried out by adopting several techniques, according to the nature of the study and its objectives. One of these techniques is building statistical models, which is done through regression models. This technique is considered one of the most important statistical methods for studying the relationship between a dependent variable, also called (the response variable) and the other variables, called covariate variables. This research describes the estimation of the partial linear regression model, as well as the estimation of the “missing at random” values (MAR). Regarding the
... Show MoreSecurity concerns in the transfer of medical images have drawn a lot of attention to the topic of medical picture encryption as of late. Furthermore, recent events have brought attention to the fact that medical photographs are constantly being produced and circulated online, necessitating safeguards against their inappropriate use. To improve the design of the AES algorithm standard for medical picture encryption, this research presents several new criteria. It was created so that needs for higher levels of safety and higher levels of performance could be met. First, the pixels in the image are diffused to randomly mix them up and disperse them all over the screen. Rather than using rounds, the suggested technique utilizes a cascad
... Show MoreThe electrospun nanofibers membranes (ENMs) have gained great attention due to their superior performance. However, the low mechanical strength of ENMs, such as the rigidity and low strength, limits their applications in many aspects which need adequate strength, such as water filtration. This work investigates the impact of electrospinning parameters on the properties of ENMs fabricated from polyacrylonitrile (PAN) solved in N, N-Dimethylformamide (DMF). The studied electrospinning parameters were polymer concentration, solution flow rate, collector rotating speed, and the distance between the needle and collector. The fabricated ENMs were characterized using scanning electron microscopy (SEM) to understand the surface morphology and es
... Show MoreThe research aim to the usage educational method for jump shooting and it effect on speed strength in basketball for the specialist students in College Sport of Dayla University, which used the following statistic treatment (The T.test for compatible specimens), so after statistic treatment which appears theres a tow moral differences in speed strength and jump shooting tests results to (legs & arms) for the before and after tests, and after that the conclusions we positive and the second the special drills effect immaterial speed strength to legs and arms, so the tow researches recommended to looking after the best for educational methods that used in our sport colleges in Iraq.
A pure posteriorly posterior communicating artery (PCoA) aneurysm represents a surgical challenge. This is mainly when there is a need for good exposure of the aneurysmal neck, sac, PCoA, and anterior choroidal arteries. Ruptured pure posteriorly directed PCoA aneurysm imposes significantly extra challenge as the surgeon undergoes dissection through a tight brain. Even with measures commonly used to attain brain relaxation like the lumbar drain and cisternal fenestration. Here, we describe a technique for posterior temporal pole mobilization (TPM) as an integrated part of microsurgical clipping of ruptured pure posteriorly directed PCoA aneurysms. This technique is implicated in twenty-three successive cases of ruptured PCoA aneurys
... Show MoreTwo molecular imprinted polymer (MIP) membranes for Levofloxacin (LEV) were prepared based on PVC matrix. The imprinted polymers were prepared by polymerization of styrene (STY) as monomer, N,N methylene di acrylamide as a cross linker ,benzoyl peroxide (BPO) as an initiator and levofloxacin as a template. Di methyl adepate (DMA) and acetophenone (AOPH) were used as plasticizers , the molecular imprinted membranes and the non molecular imprinted membranes were prepared. The slopes and detection limits of the liquid electrodes ranged from -21.96 – -19.38 mV/decade and 2×10-4M- 4×10-4M, and Its response time was around 1 minute, respectively. The liquid electrodes were packed with 0.1 M standar
... Show More