Background: Hemophilia B is an X-linked recessive disorder caused by mutations in the F9 gene, causing bleeding tendency predominantly in males. The mutational spectrum of the F9 gene has not been adequately studied in Iraq. Objectives: To detect the disease-causing variants of exons 6, 7, and 8 and immediate introns of F9 gene using Sanger sequencing among Iraqi hemophilia B patients and to correlate them with phenotypes. Methods: Forty Iraqi hemophilia B patients were recruited for this cross-sectional study from The Hereditary Bleeding Disorder Ward in the Children Welfare Teaching Hospital, Medical City, Baghdad, between November 2021 and April 2022 using a consecutive sampling technique. Peripheral blood samples were used for sequencing exons 6, 7, and 8, which encode catalytic serine protease (SP), linker, and activation peptide domains and immediate introns of the F9 gene using Sanger sequencing. Results: Nineteen (47.5%) patients had positive conclusive results. Fifteen unique variants were detected; 12 (80%) of them were disease-causing. Nine variants were located in the SP, one in the linker domain, and two in the splice site of intron 6. The most common pathogenic variant was the c.572G>A (p.Arg191His) on the linker domain as seen in six patients, while c.880C>T (p.Arg294Ter) and c.1358G>T (p.Trp453Leu) were the most common pathogenic variants of the SP domain as seen in two patients each. The vast majority were point mutations that are generally similar to the reported phenotype. Conclusion: Molecular profiling of F9 gene in the current cohort confirms 12 disease-causing variants, making molecular diagnosis and genetic counseling of hemophilia B possible. It explained the discrepancy between FIX level and clinical course, and variable severity among family members. Integrating genetic data into national registries will expand the molecular database for important health conditions in Iraq, improving healthcare provision through genetic counseling, prevention, and prenatal diagnosis.
This paper presents the implementation of a complex fractional order proportional integral derivative (CPID) and a real fractional order PID (RPID) controllers. The analysis and design of both controllers were carried out in a previous work done by the author, where the design specifications were classified into easy (case 1) and hard (case 2) design specifications. The main contribution of this paper is combining CRONE approximation and linear phase CRONE approximation to implement the CPID controller. The designed controllers-RPID and CPID-are implemented to control flowing water with low pressure circuit, which is a first order plus dead time system. Simulation results demonstrate that while the implemented RPID controller fails to stabi
... Show MoreIn this paper, a miniaturized 2 × 2 electro-optic plasmonic Mach– Zehnder switch (MZS) based on metal–polymer–silicon hybrid waveguide is presented. Adiabatic tapers are designed to couple the light between the plasmonic phase shifter, implemented in each of the MZS arms, and the 3-dB input/output directional couplers. For 6 µm-long hybrid plasmonic waveguide supported by JRD1 polymer (r33= 390 pm/V), a π-phase shift voltage of 2 V is obtained. The switch is designed for 1550 nm operation wavelength using COMSOL software and characterizes by 2.3 dB insertion loss, 9.9 fJ/bit power consumption, and 640 GHz operation bandwidth
In the geotechnical and terramechanical engineering applications, precise understandings are yet to be established on the off-road structures interacting with complex soil profiles. Several theoretical and experimental approaches have been used to measure the ultimate bearing capacity of the layered soil, but with a significant level of differences depending on the failure mechanisms assumed. Furthermore, local displacement fields in layered soils are not yet studied well. Here, the bearing capacity of a dense sand layer overlying loose sand beneath a rigid beam is studied under the plain-strain condition. The study employs using digital particle image velocimetry (DPIV) and finite element method (FEM) simulations. In the FEM, an experiment
... Show MoreBackground: Anaemia is a major public health concern and is one of the most prevalent health issue in women within reproductive age group.
Objective: to assess maternal knowledge related to anaemia during pregnancy.
Type of the study: A cross –sectional study.
Method: The study including 200 mothers who attended selected primary health care centres, Baghdad during November and December 2015, they completed a previously prepared questionnaire coveringsocio-demographic characteristics and knowledge regarding anaemia in 4 main domains. The responses were analysed by using frequency, percentage and percent score for each statement a
... Show MoreAuthors in this work design efficient neural networks, which are based on the modified Levenberg - Marquardt (LM) training algorithms to solve non-linear fourth - order three -dimensional partial differential equations in the two kinds in the periodic and in the non-periodic - Periodic. Software reliability growth models are essential tools for monitoring and evaluating the evolution of software reliability. Software defect detection events that occur during testing and operation are often treated as counting processes in many current models. However, when working with large software systems, the error detection process should be viewed as a random process with a continuous state space, since the number of faults found during testin
... Show Moreنحو تعزيز المشاركة السياسية للطالبات الجامعيات الفلسطينيات
Objective: To compare two positioning approaches in the surgical treatment of unstable intertrochanteric femoral fractures fixed by proximal femoral nailing, the supine versus lateral decubitus position Methodology: This randomized prospective comparative study on 26 patients with unstable intertrochanteric fractures was carried out from January 2020 and June 2022. We randomly divided patients into two groups: group A (13 patients) were operated using the traction table in the supine position for implant insertion, and group B (13 patients) were operated using the lateral decubitus position. We compared both groups regarding the setup time, operative time, tip-to-apex distance, collodiaphyseal angle, time for fluoroscopic time expo
... Show More