Objectives: Umbilical cord blood can be taken at birth and largely gives indication of fetal and maternal conditions. The aim of the study was to investigate the relation between sex hormones in cord blood and birth weight of newborns and pregnancy complications. Methods: Fifty cord blood samples were collected from newborns at labor room of Baghdad Teaching Hospital between May and October 2018. Blood was withdrawn from their mothers for lead analysis. Five milliliters (ml) of cord blood was taken, 3 ml was used for testosterone and estradiol analysis (using enzyme-linked immunosorbent assay) and 2 ml for lead measurement by lead care analyzer. Newborns weight and head circumference were measured. Delivered women were divided into four groups: Women with normal pregnancy, women with pre-eclampsia, diabetic women and polycystic ovary syndrome (PCOS) women. Results: There was no significant difference in age between women in all groups (P > 0.05). Birth weights, estradiol, and testosterone were significantly different between groups. Estradiol was higher in cord blood of newborns of PCOS women (P < 0.05) than others. Testosterone was higher in cord blood of babies of PCOS and pre-eclampsia women compared with those of diabetes (P < 0.05). There were no significant differences between male and female neonates regarding cord estradiol (3596.27 ± 1934.69, 3714.57 ± 1581.47 pg/ml respectively), and testosterone (393.18 ± 87.14, 361.43 ± 102.14 ng/ml respectively) (P > 0.05). Maternal lead levels correlated positively with cord lead (r = 0.905, P < 0.05), which correlated negatively with head circumference (r = −0.766, P < 0.05). Birth weight correlated negatively with estradiol (r = −0.295), but positively with testosterone (r = 0.006) (P > 0.05). Conclusion: Cord blood estradiol and testosterone levels do not differ between males and females. Estradiol was high in cord blood of PCOS mothers. Testosterone was high in cord blood of PCOS and pre-eclampsia mothers. The increase in cord lead causes decrease in babies head circumference.
Metal complexes of Cu (II), Fe (III) and Mn (II) with Quinaldic acid (L1) and 1, 10-Phenathroline (L2) are synthesized and characterized by standaral physic- chemical procedures (element analysis, metal analysis, FTIR, Uv-Vis, magnetic moment and conductometeric measurements). On the base of these studies, mononuclear and six coordinated octahedral geometry and nonelectrolyte of these complexes have been proposed. The standard heat of formation (?Hºf) and binding energy (?Eb) for the free ligands and their complexes are calculated by using the PM3 method at 273K of Hyperchem.-8 program. The complexes are more stable than their ligands. Moreover, the electrostatic potential of free ligands are measured to investigate the reactive site of th
... Show MoreThe reaction of poly (vinyl alcohol) (PV A) with Urea in (DMSO) resulted in uerthanised oxim, wr,ich reacted with diacetylmonoxime in a (DY.ISOfmethanol) to give anew type (N2) polymeric bidentate imine oxime ligand [HL], The ligand was reacted with MCh (where M= Co, Cu, and Hg). Under reflux in a (DMF/Methanol) mixture with (I:1) ratio to give Complexes of the general formula [M (T.)2]X, (where M= Co,Hg, Cu). All .:ompouncs have been characterized by spectroscopic methods [IR, U.V.-Vis, A tomi<;absorption] microanalysis along with conductivity measurements, from the above:: data the proposed molecular structure for Co,Cu, and Hg is a distorted. Tetrahedml
This systematic review aimed to analyse available evidence to answer two focused questions about the efficacy of erythritol powder air‐polishing (EPAP) (i) as an adjunctive during active periodontal therapy (APT) and (ii) as an alternative to hand/ultrasonic instrumentation during supportive periodontal therapy (SPT). Additionally, microbiological outcomes and patient's comfort/perceptions were assessed as secondary outcomes.
PubMed, Cochrane and Medline were searched for relevant articles published before February 2021 following PRISMA guidelines. The search was conducted by three indep
The main role of infill drilling is either adding incremental reserves to the already existing one by intersecting newly undrained (virgin) regions or accelerating the production from currently depleted areas. Accelerating reserves from increasing drainage in tight formations can be beneficial considering the time value of money and the cost of additional wells. However, the maximum benefit can be realized when infill wells produce mostly incremental recoveries (recoveries from virgin formations). Therefore, the prediction of incremental and accelerated recovery is crucial in field development planning as it helps in the optimization of infill wells with the assurance of long-term economic sustainabi
Metabolic dysregulation and obesity are associated with many metabolic alterations, including impairment of insulin sensitivity and dyslipidemia. Recent studies highlight the key role of phosphatidylinositol 3,4,5-triphosphate-dependent Rac exchange proteins (PREX proteins) in the pathogenesis of obesity, advocating further elucidation of their potential therapeutic implications. The present study aimed to estimate the serum level of PREX proteins and its potential association with insulin resistance markers and plasma lipids level in obese and overweight non-diabetic patients. The study included 30 persons classified as obese, 30 as overweight, and 30 healthy individuals of similar age and gender. The levels of PREX1 and PREX2 were
... Show MoreA simple reverse-phase high performance liquid chromatographic method for the simultaneous analysis (separation and quantification) of furosemide (FURO), carbamazepine (CARB), diazepam (DIAZ) and carvedilol (CARV) has been developed and validated. The method was carried out on a NUCLEODUR® 100-5 C18ec column (250 x 4.6 mm, i. d.5μm), with a mobile phase comprising of acetonitrile: deionized water (50: 50 v/v, pH adjusted to 3.6 ±0.05 with acetic acid) at a flow rate 1.5 mL.min-1 and the quantification was achieved at 226 nm. The retention times of FURO, CARB, DIAZ and CARV were found to be 1.90 min, 2.79 min, 5.39 min and 9.56 min respectively. The method was validated in terms of linearity, accuracy, precision, limit of detection and li
... Show More