Leucine amino peptidases (LAP; EC 3.4.11.1) constitute a diverse set of exopeptidases that catalyze the hydrolysis of leucine residues from the amino-terminal of protein or peptide substrates, (LAP) are present in animals, plants, and microbes. In this study, leucine amino peptidase was purified partial from Arachis hypogaea seeds by using gel filtration chromatography Sephadex G-100. The enzyme was purified 3.965 fold with a recovery of 29.4%. Its pH and temperature optimum were(8.7) and (37oC), respectively. The results show novel properties of LAP from Arachis hypogaea L. or peanut. The Km value for LAP (77 mM), with V max (1538 m mole min-1). We recommend a separate isoenzymeof the enzyme (LAP) from Arachis hypogaea on L. peanut seeds a
... Show MoreBeta-lactamase was purified from local isolate Klebsiella pneumonia by several steps included precipitation with ammonium sulphate at 20-40% saturation, DEAE- ion exchange chromatography and gel filtration on Sephacryl S-200 column. The obtained purification fold and recovery were 32.66; 47.04% respectively. The characterization of the purified beta-lactamase showed that the molecular weight was about 4000 daltons as determined by gel filtration.Purified enzyme had an optimal pH of 7 for activity and an optimal stability between pH 6.5-7.5, results shows that the optimal temperature appear to be 35 ? C .During storage the enzyme retained 72% at -20 ? C and retained 25% of the activity at the same period at 4 ? C.
The sorption of Cu2+ ions from synthetic wastewater using crushed concrete demolition waste (CCDW) which collected from a demolition site was investigated in a batch sorption system. Factors influencing on sorption process such as shaking time (0-300min), the initial concentration of contaminant (100-750mg/L), shaking speed (0-250 rpm), and adsorbent dosage (0.05-3 g/ml) have been studied. Batch experiments confirmed that the best values of these parameters were (180 min, 100 mg/l, 250 rpm, 0.7 g CCDW/100 ml) respectively where the achieved removal efficiency is equal to 100%. Sorption data were described using four isotherm models (Langmuir, Freundlich, Redlich-Peterson, and Radke-Prausnitz). Results proved that the pure ads
... Show MorePolymeric microsphere devices occupy a wide range in the field of controlled drug delivery. Subcutaneous injectable preparations of Poly(Lactide-co-Glycolide) (PLGA) microsphere of Daptomycine were prepared by solvent extraction/evaporation technique using different copolymers ratio and molecular weights. Four formulations were prepared (F1-F4) and characterized in term of particle size, surface morphology, bulk density and porosity in addition to the drug content. The effects of the above parameters on the in-vitro release study were evaluated. These formulas were evaluated also for their in-vivo release profile using rat (as an animal model) and
... Show MoreMetronidazole-MIPs were prepared by using (MDZ) as the template as well as allylchloride (AYC) or allylbromide (AYB) as monomer, used (TMPTA) tri-methylol propane tri-acrylate or ethylene glycol di-methyl acrylate (EGDMA) as cross-linker and initiator used (BP) benzyl peroxide. By using different plasticizers (di butyl Phthalate (DBPH), Nitrobenzene (NB), oleic acid (OA) and paraffin) for MDZ-MIP1 and (Di-butyl sebecate (DBS), Di-methyl acrylate (DMA), Tributylphosphate(TBP) and Tris(ethylhexyl phosphate (TEHP) ) for MDZ-MIP2. Membranes of MIPs were prepared in PVC matrix. The characterizations of each electrode were determined The Slope range from (55.083 - 43.711) mV/decade, Limit of Detection (8 X 10 -4- 2 X 10-6) and Linearity
... Show More