The angiotensin converting enzyme (ACE) I\D gene polymorphism influences the blood ACE enzyme activity. Renoprotective effect of ACE inhibitors (ACEIs) varies among patients due to genetic variation, particularly in Renin-Angiotensin-Aldosterone System genes. This study investigates the genetic variations of ACE I\D and AGT1RA1166C gene polymorphisms in the antiproteinuric effect of ACEI therapy in type 2 diabetes mellitus (T2DM) patients. This is a cross-sectional study that included 76 T2DM patients who are ACEI users, divided into two groups: T2DM without diabetic kidney disease (DKD) included 31 patients, and T2DM with DKD included 45 patients. Urine samples were taken for measurement of urine albumin and creatinine, then calculation of albumin-creatinine ratio (ACR). Blood samples were taken for the measurement of serum parameters and also for the extraction of DNA for genetic evaluation of ACEI/D and AGT1RA1166C gene polymorphisms. The results reveal that T2DM patients carrying the ID genotype have significantly lower ACE1 levels compared to DD and II carriers (p = 0.012). When grouping patients according to the ACR, serum ACE1 and angiotensin-converting enzyme 2 (ACE2) levels were higher in DKD compared to normalbuminuric patients, with the only significant difference for ACE2. After subdividing according to ACE I\D genotypes, the ACE2 differences were only significant in DD genotype carriers (p = 0.049) between DKD and normalbuminuric groups. While for AGT1RA1166C polymorphisms, the AC genotype shows non-significantly lower levels for ACE1 and ACE2. After subdividing according to AGT1RA1166C genotypes, ACE2 levels were significantly higher in DKD patients carrying the AA genotype (p = 0.015). Binary logistic regression analysis revealed that both ACE (I\D) and AGT1RA1166C genes are significant predictors of ACE1 levels after controlling age, gender, and DKD state. This study concluded that both genes are predictors of ACE1 levels; in addition, ID genotype carriers and AC genotype carriers had lower ACE1 and ACE2 levels with lower ACR and higher glomerular filtration rate, identifying better ACEIs responses in ID and AC carriers.
The preparation of low cost activated carbon from date stones and microwave method by using K2CO3 as chemical activator were investigated.
The prepared activated carbon was used to remove fluoroquinolones antibiotics from aqueous solution. The characterizations of the activated carbon is represented by surface area, pore volume, ash content, moisture content, bulk density, and iodine number. The adsorbed fluoroquinolones antibiotics are Ciprofloxcin (CIP), Norfloxcin (NOR) and Levofloxcin (LEVO). Different variables as pH, initial concentrations and contact time were studied to show the efficieny of prepared activated carbon. The experimental adsorption data were analyzed by Lungmuir, Freundlich
... Show MoreIMPLICATION OF GEOMECHANICAL EVALUATION ON TIGHT RESERVOIR DEVELOPMENT / SADI RESERVOIR HALFAYA OIL FIELD
Treatment of a high strength acidic industrial wastewater was attempted by activated carbon
adsorption to evaluate the feasibility of yielding effluents of reusable qualities. The experimental
methods which were employed in this investigation included batch and column studies. The
former was used to evaluate the rate and equilibrium of carbon adsorption, while the latter was
used to determine treatment efficiencies and performance characteristics. Fixed bed and expanded
bed adsorbers were constructed in the column studies. In this study, the adsorption behavior of acetic acid onto activated carbon was examined as a function of the concentration of the adsorbate, contact time and adsorbent dosage. The adsorption data was mo
Conventional concretes are nearly unbendable, and just 0.1 percent of strain potential makes them incredibly brittle and stiff. This absence of bendability is a significant cause of strain failure and has been a guiding force in the production of an elegant substance, bendable concrete, also known as engineered cement composites, abbreviated as ECC. This type of concrete is capable of displaying dramatically increased flexibility. ECC is reinforced with micromechanical polymer fibers. ECC usually uses a 2 percent volume of small, disconnected fibers. Thus, bendable concrete deforms but without breaking any further than conventional concrete. This research aims to involve this type of concrete, bendable concrete, that will give solut
... Show MoreIn this paper, a new analytical method is introduced to find the general solution of linear partial differential equations. In this method, each Laplace transform (LT) and Sumudu transform (ST) is used independently along with canonical coordinates. The strength of this method is that it is easy to implement and does not require initial conditions.
Akaike’s Information Criterion (AIC) is a popular method for estimation the number of sources impinging on an array of sensors, which is a problem of great interest in several applications. The performance of AIC degrades under low Signal-to-Noise Ratio (SNR). This paper is concerned with the development and application of quadrature mirror filters (QMF) for improving the performance of AIC. A new system is proposed to estimate the number of sources by applying AIC to the outputs of filter bank consisting quadrature mirror filters (QMF). The proposed system can estimate the number of sources under low signal-to-noise ratio (SNR).
A new modified differential evolution algorithm DE-BEA, is proposed to improve the reliability of the standard DE/current-to-rand/1/bin by implementing a new mutation scheme inspired by the bacterial evolutionary algorithm (BEA). The crossover and the selection schemes of the DE method are also modified to fit the new DE-BEA mechanism. The new scheme diversifies the population by applying to all the individuals a segment based scheme that generates multiple copies (clones) from each individual one-by-one and applies the BEA segment-wise mechanism. These new steps are embedded in the DE/current-to-rand/bin scheme. The performance of the new algorithm has been compared with several DE variants over eighteen benchmark functions including sever
... Show MoreThis paper aims to study the second-order geometric nonlinearity effects of P-Delta on the dynamic response of tall reinforced concrete buildings due to a wide range of earthquake ground motion forces, including minor earthquake up to moderate and strong earthquakes. The frequency domain dynamic analysis procedure was used for response assessment. Reinforced concrete building models with different heights up to 50 stories were analyzed. The finite element software ETABS (version 16.0.3) was used to analyze reinforced concrete building models.
The study reveals that the percentage increase in buildings' sway and drift due to P-Delta effects are nearly constant for specific building height irrespective of the seism
... Show MoreThe performance of a solar assisted desiccant cooling system for a meeting-hall located in the College of Engineering/University of Baghdad was evaluated theoretically. The system was composed of four components; a solar air heater, a desiccant dehumidifier, a heat exchanger and an evaporative cooler. A computer simulation was developed by using MATLAB to assess the effect of various design and operating conditions on the performance of the system and its components. The actual weather data on recommended days were used to assess the load variation and the system performance during those days. The radiant time series method (RTS) was used to evaluate the hourly variation of the cooling load. Four operation modes were employed for perform
... Show More