This study aimed at identifying the trend to applying the Joint Audit as an approach to improve the financial reports quality with all their characteristics (Relevance, Reliability, Comparability, Consistency), as well as enclose the difficulties that faced the auditors in the Gaza Strip in implementing the Joint Audit. In order to achieve the study aims, a measure was used to identify the trend to apply the Joint Audit and it was distributed to the study sample which is consisting of (119) individuals and retrieved thereof (99) valid for analysis, approximately (83.2%), (69) of them are Auditors, (30) financial managers and accountants. The researcher used the analytical descriptive method, and after analyzing the results, the s
... Show MoreIn this study, a 3 mm thickness 7075-T6 aluminium alloy sheet was used in the friction stir welding process. Using the design of experiment to reduce the number of experiments and to obtain the optimum friction stir welding parameters by utilizing Taguchi technique based on the ultimate tensile test results. Orthogonal array of L9 (33) was used based on three numbers of the parameters and three levels for each parameter, where shoulder-workpiece interference depth (0.20, 0.25, and 0.3) mm, pin geometry (cylindrical thread flat end, cylindrical thread with 3 flat round end, cylindrical thread round end), and thread pitch (0.8, 1, and 1.2) mm) this technique executed by Minitab 17 software. The results showed th
... Show MoreObjectives: Recently, there have been important advances in the clinical application of targeted hybrid near-infrared (NIR) fluorescent-radioactive tracers. ICG-99mTc-nanocolloid, for example, is already being used by some centres for sentinel lymph node biopsy in head and neck cancer. The radioactive component allows imaging at depths which would not be possible with NIR alone and, once exposed, the NIR fluorescence reporter can be imaged at very high resolution. Gamma detection is currently carried out with a separate hand-held gamma camera or with a non-imaging probe. Visualisation of NIR fluorescence during surgery requires a dedicated NIR camera, several of which are available commercially. We describe a novel hand-held hybrid NIR-gamm
... Show MoreThis paper proposes a compact, plasmonic-based 4 × 4 nonblocking switch for optical networks. This device uses six 2 × 2 plasmonic Mach-Zehnder switch (MZS), whose arm waveguide is supported by a JRD1 polymer layer as a high electro-optic coefficient material. The 4 × 4 switch is designed in COMSOL environment for 1550 nm wavelength operation. The performance of the proposed switch outperforms those of conventional (nonplasmonic) counterparts. The designed switch yields a compact structure ( 500 × 70 µ m 2 ) having V π L = 12 V · µ m , 1.5 THz optical bandwidth, 7.7 dB insertion loss, and −26.5 dB crosstalk. The capability of the switch to route 8 × 40 Gbps WDM signal is demonstrated successfully.
... Show MoreThis paper proposes a hybrid speech enhancement estimator that integrates the Perceptually-motivated Karhunen–Loève Transform (PKLT) with the Dual-Masking Harmonic-based (DMH) algorithm in a unified framework termed PKDMH. The main novelty lies in combining perceptual subspace projection with harmonic-residual suppression, enabling the system to jointly remove noise while preserving speech-relevant spectral cues. PKLT first performs perceptual subspace projection and suppresses inaudible components, after which DMH eliminates remaining broadband and harmonic residuals. The proposed PKDMH system was evaluated using the TIMIT dataset contaminated with five noise types: White, Pink, F16, Airport, and Car noise—across five SNR leve
... Show More