Photoplethysmography (PPG) is a non-invasive optical technique that employs variations in light absorption produced by alteration in the blood volume in capillaries at the skin during the cardiac cycle. This study aims to understand factors related to PPG morphology; a hand-elevation, the study has modified blood flow to and from the finger was conducted in the laboratory. It is widely established that the position of the limb relative to the heart has an effect on blood flow in arteries and venous. Peripheral digital pulse wave (DPW) signals were obtained from 15 healthy volunteer participants during hand-elevation, and hand-lowering techniques wherein the right hand was lifted and lowered relative to heart level, while the left hand remained static. The pulse width, time to peak (TTP), the time to the maximum slope (TTMas) were computed from 30sec DPW signals at three positions of the right hand with regard to heart level, i.e. 35 cm above heart level (+35 cm), at the level of the heart (0 cm), and 35 cm below the level of the heart (-35 cm). DPW characteristics were found to alter with hand position. On lowering the hand to -35 cm relative to heart level, DPW width from the middle finger increased by (6%), but lowering the arm decreased the TTP (by 11 %), TTMas (by 18 %). These changes in time-dependent DPW indices may be attributed to changes in hydrostatic pressure and the venoarterial reflex that changes the blood vessels filling from completely filled one at -35 cm due to arterial vasoconstriction and decreased venous return to partially emptied blood vessels due to arterial vasodilatation and increased venous return at +35 cm. It was assumed that these time-dependent morphological DPW indices alterations were controlled by changes in downstream venous resistance rather than arterial or arteriolar, resistance. Keywords: photo plethysmography, hand elevation, vasoconstriction, vasodilation, vascular mechanics
The relationship between blood group antigens and peptic ulcer disease has been widely evaluated in the past, but only one study relating H pylori seroprevalence to ABO blood groups among Iraqi patients with peptic ulcer disease is available. We aimed to evaluate the frequency of peptic ulcer disease among different ABO blood groups in Iraqi patients, and we thought it was worthwhile to try to determine whether these components take some part in disease etiology. One hundred and six patients with peptic ulcer disease (PUD) (43 male and 63 female; mean age: 48 ± 18 years) who attended Baghdad teaching hospital and Al- Yarmouk teaching hospital endoscopy centers were enrolled , and 238 control Subjects. Fing
... Show MoreObjectives: the study aims to assess nurses' practices toward chemotherapy-induced peripheral neuropathy (CIPN) for children at the hematology center, and to determine the effectiveness of the health education program on nurses' practices toward CIPN, and to find out the relationships between the effectiveness of Health education program and demographic characteristics of nurses.
Methodology: Use quasi-experimental design in the study (a design that divides the sample into two groups, a study group and a control group, with data collection in three stages). This study was conducted at a hematology center in Baghdad city for the period (from December 16th, 2019 to 8th May 202
... Show MoreNon-thermal argon plasma needle at atmospheric pressure was
constructed. The experimental setup was based on a simple and low
cost electric component that generates a sufficiently high electric
field at the electrodes to ionize the argon gas which flow at
atmospheric pressure. A high AC power supply was used with 1.1
kV and 19.57 kHz. Non-thermal Argon plasma used on blood
samples to show the ability of non-thermal plasma to promote blood
coagulation. Three tests have been done to show the ability of plasma
to coagulate both normal and anti-coagulant blood. Each blood
sample has been treated for varying time from 20sec. to 180sec. at
different distances. The results of the current study showed that the
co
Arterial aneurism and stenosis are disorders that lead to circulation malfunction. Stenosis often leads to hypoxia of the organ depending on the affected artery, whilst aneurism can lead to dissection with known lethal consequences. On both cases, the pulse wave produced by the contracting heart is reflected at these discontinuities, and estimating the size of these reflected waves using wave intensity analysis (WIA) is the main aim of this work. We also aim to measure wave speed, or pulse wave velocity (PWV) as more commonly known within the discontinuities. We manufactured 4 stenosis and 4 aneurism silicon sections, connected one at a time to a mother tube, and tested in vitro. Pressure and flow were measured proximal to the discontinuity
... Show MoreThe world is keeping pace with evolution in all its fields as a result of scientists' pursuit of continuous scientific and technological development. This evolution included the sports field, which had a large space in the aspect of development and for all disciplines, Therefore, it's reflected today in what we see of records and advanced achievements in sporting events and activities. The development in the field of sports was the result of scientific research (Hussein and Jawad., 2022), where the interest in the training process has become one of the most important pillars of the development of achievement (Neamah and Altay., 2020). The shooting sport has also witnessed a remarkable development due to the diversity and development of its
... Show MoreAbstract
This paper is an experimental work to determinate the effect of welding velocity and formed arc energy for CO2-MAG fusion weld pool. The input parameters (arc voltage, wire feed speed and gas flow rate) were investigated to find their effects on the weld joint efficiency. Design of experiment with response surface methodology technique was used to build empirical mathematical models for welding velocity and arc energy in term of the input welding parameters. The predicted quadratic models were statistically checked for adequacy purpose by ANOVA analysis. Additionally, numerical optimization was conducted to obtain the optimum values for welding velocity and arc energy. A good agree
... Show MoreIn this work, plasma parameters such as, the electron temperature )Te(, electron density ne, plasma frequency )fp(, Debye length )λD(
and Debye number )ND), have been studied using optical emission spectroscopy technique. The spectrum of plasma with different values of energy, Pb doped CuO at different percentage (X=0.6, 0.7, 0.8) were recorded. The spectroscopic study for these mixing under vacuum with pressure down to P=2.5×10-2 mbar. The results of electron temperature for X=0.6 range (1.072-1.166) eV, for X=0.7 the Te range (1.024-0.855) eV and X=0.8 the Te is (1.033-0.921) eV. Optical properties of CuO:Pb thin films were determined through the optical transmission method using ultraviolet visible spectrophotometer within the ra
In this work, plasma parameters such as (electron temperature (Te), electron density (ne), plasma frequency (fp) and Debye length (λD)) were studied using spectral analysis techniques. The spectrum of the plasma was recorded with different energy values, SnO2 and ZnO anesthetized at a different ratio (X = 0.2, 0.4 and 0.6) were recorded. Spectral study of this mixing in the air. The results showed electron density and electron temperature increase in zinc oxide: tin oxide alloy targets. It was located that The intensity of the lines increases in different laser peak powers when the laser peak power increases and then decreases when the force continues to increase.
Due to the urgent need to develop technologies for continuous glucose monitoring in diabetes individuals, poten tial research has been applied by invoking the microwave tech niques. Therefore, this work presents a novel technique based on a single port microwave circuit, antenna structure, based on Metamaterial (MTM) transmission line defected patch for sensing the blood glucose level in noninvasive process. For that, the proposed antenna is invoked to measure the blood glu cose through the field leakages penetrated to the human blood through the skin. The proposed sensor is constructed from a closed loop connected to an interdigital capacitor to magnify the electric field fringing at the patch center. The proposed an tenna sensor i
... Show More